The potential of iodinated contrast reduction in dual-energy CT thoracic angiography; an evaluation of image quality

被引:16
作者
Johansen, C. B. [1 ,2 ]
Martinsen, A. C. T. [2 ,3 ]
Enden, T. R. [1 ]
Svanteson, M. [1 ,4 ]
机构
[1] Oslo Univ Hosp, Dept Radiol & Nucl Med, Oslo, Norway
[2] Oslo Metropolitan Univ, Fac Hlth Sci, Oslo, Norway
[3] Sunnaas Rehabil Hosp, Alvaern, Norway
[4] Oslo Univ Hosp, Dept Diagnost Phys, ImTECH, Oslo, Norway
关键词
Computer tomography; Contrast media; Spectral imaging; Iodine; Monoenergetic images; TO-NOISE RATIO; COMPUTED-TOMOGRAPHY; RESOLUTION; PHANTOM;
D O I
10.1016/j.radi.2021.07.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The purpose of this study was to compare a dual energy CT (DECT) protocol with 50% reduction of iodinated contrast to a single energy CT (SECT) protocol using standard contrast dose in imaging of the thoracic aorta. Methods: DECT with a 50% reduction in iodinated contrast was compared with SECT. For DECT, mono-energetic images at 50, 55, 60, 65, 68, 70, and 74 keV were reconstructed with adaptive statistical iterative reconstruction (ASiR-V) of 50% and 80%. Objective image quality parameters included intravascular attenuation (HU), image noise (SD), contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR). Two independent radiologists subjectively assessed the image quality for the 55 and 68 keV DECT reconstructions and SECT on a five-point Likert scale. Results: Across 14 patients, the intravascular attenuation at 50-55 keV was comparable to SECT (p > 0.05). The CNRs were significantly lower for DECT with ASIR-V 50% compared to SECT for all keV-values (p < 0.05 for all). For ASIR-V 80%, CNR was comparable to SECT at energies below 60 keV (p > 0.05). The subjective image quality was comparable between DECT and SECT independent of keV level. Conclusion: This study indicates that a 50% reduction in iodinated contrast may result in adequate image quality using DECT with monoenergetic reconstructions at lower energy levels for the imaging of the thoracic aorta. The best image quality was obtained for ASiR-V 80% image reconstructions at 55 keV. Implications of practice: Dual energy CT with a reduction in iodinated contrast may result in adequate image quality in imaging of the thoracic aorta. However, increased radiation dose may limit the use to patients in which a reduction in fluid and iodinated contrast volume may outweigh this risk. (C) 2021 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:2 / 7
页数:6
相关论文
共 28 条
[1]   Ultra-low dose chest computed tomography: Effect of iterative reconstruction levels on image quality [J].
Afadzi, Mercy ;
Lysvik, Elisabeth Kirkeby ;
Andersen, Hilde Kjernlie ;
Martinsen, Anne Catrine T. .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 114 :62-68
[2]   Coronary CT angiography with 80 kV tube voltage and low iodine concentration contrast agent in patients with low body weight [J].
Andreini, Daniele ;
Mushtaq, Saima ;
Conte, Edoardo ;
Segurini, Chiara ;
Guglielmo, Marco ;
Petulla, Maria ;
Volpato, Valentina ;
Annoni, Andrea ;
Baggiano, Andrea ;
Formenti, Alberto ;
Bartorelli, Antonio L. ;
Fiorentini, Cesare ;
Pepi, Mauro .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (04) :322-326
[3]  
Andreucci M, 2017, DRUG HEALTHC PATIENT, V9, P25, DOI 10.2147/DHPS.S122207
[4]   Low radiation dose in computed tomography: the role of iodine [J].
Aschoff, Andrik J. ;
Catalano, Carlo ;
Kirchin, Miles A. ;
Krix, Martin ;
Albrecht, Thomas .
BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1076)
[5]   Contrast-to-Noise Ratio and Low-Contrast Object Resolution on Full- and Low-Dose MDCT: SAFIRE Versus Filtered Back Projection in a Low-Contrast Object Phantom and in the Liver [J].
Baker, Mark E. ;
Dong, Frank ;
Primak, Andrew ;
Obuchowski, Nancy A. ;
Einstein, David ;
Gandhi, Namita ;
Herts, Brian R. ;
Purysko, Andrei ;
Remer, Erick ;
Vachani, Neil .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) :8-18
[6]   New Applications of Cardiac Computed Tomography Dual-Energy, Spectral, and Molecular CT Imaging [J].
Danad, Ibrahim ;
Fayad, Zahi A. ;
Willemink, Martin J. ;
Min, James K. .
JACC-CARDIOVASCULAR IMAGING, 2015, 8 (06) :710-723
[7]   A Third-Generation Adaptive Statistical Iterative Reconstruction Technique: Phantom Study of Image Noise, Spatial Resolution, Lesion Detectability, and Dose Reduction Potential [J].
Euler, Andre ;
Solomon, Justin ;
Marin, Daniele ;
Nelson, Rendon C. ;
Samei, Ehsan .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (06) :1301-1308
[8]  
Fan J., 2014, White paper
[9]   Diagnostic value of iterative reconstruction algorithm in low kV CT angiography (CTA) with low contrast medium volume for transcatheter aortic valve implantation (TAVI) planning: image quality and radiation dose exposure [J].
Franzesi, Cammillo R. Talei ;
Ippolito, Davide ;
Riva, Luca ;
Fior, Davide ;
Cangiotti, Cecilia ;
Sironi, Sandro .
BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1092)
[10]   Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study [J].
Ippolito, D. ;
Franzesi, C. Talei ;
Fior, D. ;
Bonaffini, P. A. ;
Minutolo, O. ;
Sironi, S. .
BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1049)