The role of the design and operation of individual heating systems for the energy retrofits of residential buildings

被引:25
作者
Teres-Zubiaga, J. [1 ]
Campos-Celador, A. [2 ]
Gonzalez-Pino, I. [3 ]
Diarce, G. [4 ]
机构
[1] Univ Basque Country UPV EHU, Fac Engn Bilbao, Dept Thermal Engn, ENEDI Res Grp, Rafael Moreno Pitxitxi 2, Bilbao 48013, Spain
[2] Univ Basque Country UPV EHU, Fac Engn Gipuzkoa, Dept Thermal Engn, ENEDI Res Grp, Avda Otaola 29, Eibar 20600, Spain
[3] Univ Basque Country UPV EHU, Fac Engn Bilbao, Dept Thermal Engn, ENEDI Res Grp, Alda Urquijo S-N, Bilbao 48013, Spain
[4] Univ Basque Country UPV EHU, Fac Engn Bilbao, Dept Min & Met Engn & Mat Sci, ENEDI Res Grp, Rafael Moreno Pitxitxi 2, Bilbao 48013, Spain
关键词
Energy supply systems; Holistic approach; Building energy retrofit; Energy efficiency; Rebound effect; THERMAL PERFORMANCE; NORTHERN SPAIN; CONSUMPTION; RENOVATION; IMPACT; REFURBISHMENT; EFFICIENCY; ENVELOPE; BEHAVIOR; POLICIES;
D O I
10.1016/j.enconman.2016.08.042
中图分类号
O414.1 [热力学];
学科分类号
摘要
The feasibility of individual natural gas fired boiler-based heating systems in the retrofitting of buildings constructed in the 50-60 s in Bilbao (northern Spain) is evaluated in this paper. A holistic approach through dynamic simulations using TRNSYS is employed for the purpose. An existing dwelling previously monitored and used to validate the model applied is selected as a case study. 54 different scenarios are evaluated, which arise from the combination of 3 different envelope options, 2 types of heat production units, 3 heat production temperatures and 3 comfort temperature set-points. The cases are evaluated in terms of energy results, economic aspects, and the influence of user behaviour. Regarding the latter, the influence of the potential rebound effect is also evaluated. The results show energy savings nearby 10% when condensing boilers are compared with high efficiency boilers. In relation to hot water production temperature, energy savings between 5 and 10% are found when the temperature is lowered from 60 to 50 degrees C. The greatest impact on energy consumption is related to the occupants' behaviour: reductions up to 89% are achieved if the indoor temperature set-point is lowered 2 degrees C. This is reinforced with the results related to the rebound effect, which show significant differences on energy consumption values. These evidences demonstrate that the user behaviour is an essential feature to be considered in studies regarding buildings energy performance. As a consequence, the holistic approach herein employed emerges as a key tool to be applied in further works related with the topic. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:736 / 747
页数:12
相关论文
共 46 条
[1]  
AENOR, 2015, 44212015 AENOR UNEEN
[2]   Integrated evaluation of radiative heating systems for residential buildings [J].
Anastaselos, Dimitrios ;
Theodoridou, Ifigeneia ;
Papadopoulos, Agis M. ;
Hegger, Manfred .
ENERGY, 2011, 36 (07) :4207-4215
[3]  
[Anonymous], 2016, EN PRIC STAT
[4]  
[Anonymous], 2014, Forest Landscape Restoration Opportunity Assessment for Rwanda, P1
[5]  
ASHRAE, 2013, 2013 ASHRAE COMP HVA, P1
[6]   Changes in renovation policies in the era of sustainability [J].
Baek, Cheong-Hoon ;
Park, Sang-Hoon .
ENERGY AND BUILDINGS, 2012, 47 :485-496
[7]   Defining the rebound effect [J].
Berkhout, PHG ;
Muskens, JC ;
Velthuijsen, JW .
ENERGY POLICY, 2000, 28 (6-7) :425-432
[8]   Predicted versus observed heat consumption of a low energy multifamily complex in Switzerland based on long-term experimental data [J].
Branco, G ;
Lachal, B ;
Gallinelli, P ;
Weber, W .
ENERGY AND BUILDINGS, 2004, 36 (06) :543-555
[9]   Experiencing fuel poverty. Coping strategies of low-income households in Vienna/Austria [J].
Brunner, Karl-Michael ;
Spitzer, Markus ;
Christanell, Anja .
ENERGY POLICY, 2012, 49 :53-59
[10]   Evaluation of retrofitting a conventional natural gas fired boiler into a condensing boiler [J].
Che, DF ;
Liu, YH ;
Gao, CY .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (20) :3251-3266