Effects of Fluid Viscoelasticity on the Performance of an Axial Blood Pump Model

被引:2
|
作者
Hu, Qi-Hui [1 ]
Li, Jing-Yin [1 ]
Zhang, Ming-Yuan [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Fluid Machinery Inst, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
VENTRICULAR ASSIST DEVICE; TURBULENT PIPE-FLOW; DRAG-REDUCING FLUIDS; REYNOLDS-NUMBER; PREDICTIONS; REDUCTION; STRESS; VELOCIMETRY; VISCOSITY; POLYMERS;
D O I
10.1097/MAT.0b013e3182383077
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An aqueous Xanthan gum solution (XGS) was used as blood analog fluid to explore the influence of fluid viscoelasticity on the performance of an axial blood pump model. For comparison, a 39 wt% Newtonian aqueous glycerin solution (GS), the common fluid in blood pump tests, was also used as a working fluid. The experimental results showed that a higher head curve was obtained using XGS in the pump than using GS. The heads of the XGS that were computed using the viscoelastic turbulence model agreed well with the measured data. In contrast, the standard k-epsilon turbulence model failed to provide satisfactory predictions for the XGS. The computational results revealed that in most parts of the pump model flow fields, the Reynolds shear stress values and turbulent dissipation rates of the XGS were all lower than those of the GS. The hemolysis index of the pump model using the XGS was calculated to be only one-third of that using the GS. ASAIO Journal 2012; 58:32-39.
引用
收藏
页码:32 / 39
页数:8
相关论文
共 50 条
  • [1] Fluid dynamics aspects of miniaturized axial-flow blood pump
    Kang, Can
    Huang, Qifeng
    Li, Yunxiao
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 723 - 729
  • [2] A new design and computational fluid dynamics study of an implantable axial blood pump
    Mojtaba Koochaki
    Hanieh Niroomand-Oscuii
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 417 - 422
  • [3] A new design and computational fluid dynamics study of an implantable axial blood pump
    Koochaki, Mojtaba
    Niroomand-Oscuii, Hanieh
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (04) : 417 - 422
  • [4] Experimental investigation of the influence of the hydraulic performance of an axial blood pump on intraventricular blood flow
    Liu, Guang-Mao
    Jiang, Fu-Qing
    Yang, Xiao-Han
    Wei, Run-Jie
    Hu, Sheng-Shou
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2021, 44 (12) : 980 - 989
  • [5] Effects of flow geometry on blood viscoelasticity
    Thurston, George B.
    Henderson, Nancy M.
    BIORHEOLOGY, 2006, 43 (06) : 729 - 746
  • [6] NUMERICAL AND EXPERIMENTAL INVESTIGATION ON THE INFLUENCE OF BLADES GAP FLOW ON AXIAL BLOOD PUMP PERFORMANCE
    Liu, Guangmao
    Jin, Donghai
    Wang, Mengyu
    Gui, Xingmin
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2019, VOL 3B, 2019,
  • [7] Numerical Investigation of the Influence of Blade Radial Gap Flow on Axial Blood Pump Performance
    Liu, Guang-Mao
    Jin, Dong-Hai
    Zhou, Jian-Ye
    Zhang, Yan
    Chen, Hai-bo
    Sun, Han-Song
    Hu, Sheng-shou
    Gui, Xing-Min
    ASAIO JOURNAL, 2019, 65 (01) : 59 - 69
  • [8] Validation of an Axial Flow Blood Pump: Computational Fluid Dynamics Results Using Particle Image Velocimetry
    Su, Boyang
    Chua, Leok Poh
    Wang, Xikun
    ARTIFICIAL ORGANS, 2012, 36 (04) : 359 - 367
  • [9] COMPARISON OF THREE CONTROL STRATEGIES FOR AXIAL BLOOD PUMP
    Wu, Xiao
    Zhang, Xiwen
    Hao, Pengfei
    He, Feng
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (06)
  • [10] Miniaturization of a Magnetically Levitated Axial Flow Blood Pump
    Cheng, Shanbao
    Olles, Mark W.
    Olsen, Don B.
    Joyce, Lyle D.
    Day, Steven W.
    ARTIFICIAL ORGANS, 2010, 34 (10) : 807 - 815