Effect of body position on ultrasonographic estimations of bladder volume

被引:11
作者
Atalan, G [1 ]
Holt, PE [1 ]
Barr, FJ [1 ]
机构
[1] Univ Bristol, Dept Vet Clin Sci, Div Compan Anim, Bristol BS40 5DU, Avon, England
关键词
D O I
10.1111/j.1748-5827.1999.tb03786.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A study was undertaken to determine the effect of body position on ultrasonographic bladder measurements and volume estimations. Of the 42 dogs studied, 15 were fresh canine cadavers without urological disease and the remaining 27 were undergoing investigations for disorders of the lower urinary tract. Bladder volume was estimated using a formula described previously. Irrespective of whether all dogs were considered together or only live animals were included, measurements made in dorsal recumbency tended to underestimate bladder volume while those made in right lateral recumbency resulted in overestimation. This was due to significant differences in all linear measurements, apart from width, between body positions. Measurements in right lateral recumbency were higher than those in dorsal recumbency, In all animals and in living dogs alone, bladder measurements in dorsal recumbency appeared to give a more accurate estimation of actual bladder volume.
引用
收藏
页码:177 / 179
页数:3
相关论文
共 13 条
[1]  
Atalan G, 1998, AM J VET RES, V59, P10
[2]   Estimation of bladder volume-using ultrasonographic determination of cross-sectional areas and linear measurements [J].
Atalan, G ;
Barr, FJ ;
Holt, PE .
VETERINARY RADIOLOGY & ULTRASOUND, 1998, 39 (05) :446-450
[3]  
BARR F, 1990, DIAGNOSTIC ULTRASOUN, P57
[4]   ULTRASOUND ASSESSMENT OF RESIDUAL URINE - A QUANTITATIVE METHOD [J].
BEACOCK, CJM ;
ROBERTS, EE ;
REES, RWM ;
BUCK, AC .
BRITISH JOURNAL OF UROLOGY, 1985, 57 (04) :410-413
[5]  
Doust B D, 1974, J Clin Ultrasound, V2, P127, DOI 10.1002/jcu.1870020209
[6]   THE ESTIMATION OF BLADDER VOLUME BY SONOCYSTOGRAPHY [J].
HAKENBERG, OW ;
RYALL, RL ;
LANGLOIS, SL ;
MARSHALL, VR .
JOURNAL OF UROLOGY, 1983, 130 (02) :249-251
[7]  
HARRISON NW, 1976, BRIT J UROL, V47, P805
[8]   MEASUREMENT OF BLADDER VOLUME BY REAL-TIME ULTRASOUND [J].
KIELY, EA ;
HARTNELL, GG ;
GIBSON, RN ;
WILLIAMS, G .
BRITISH JOURNAL OF UROLOGY, 1987, 60 (01) :33-35
[9]   THE MEASUREMENT OF RESIDUAL URINE BY MEANS OF ULTRASOUND (SONOCYSTOGRAPHY) IN NEUROGENIC BLADDER DISTURBANCES [J].
KORNHUBER, HH ;
WIDDER, B ;
CHRIST, K .
ARCHIV FUR PSYCHIATRIE UND NERVENKRANKHEITEN, 1980, 228 (01) :1-6
[10]   EXPERIENCE WITH PORTABLE ULTRASOUND EQUIPMENT AND MEASUREMENT OF URINE VOLUMES - INTER-USER RELIABILITY AND FACTORS OF PATIENT POSITION [J].
MASSAGLI, TL ;
CARDENAS, DD ;
KELLY, EW .
JOURNAL OF UROLOGY, 1989, 142 (04) :969-971