Total arthroplasty of basal thumb joint with Elektra prothesis: an in vitro analysis

被引:2
作者
Completo, A. [1 ]
Nascimento, A. [2 ]
Neto, F. [1 ]
机构
[1] Univ Aveiro, Dept Mech Engn, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] Coimbra Univ Hosp, Dept Orthopaed, Coimbra, Portugal
关键词
Carpometacarpal joint; uncemented trapeziometacarpal prosthesis; principal cortex strains; finite element models; stress-shielding; TRAPEZIOMETACARPAL JOINT; CARPOMETACARPAL JOINT; FOLLOW-UP; BIOMECHANICAL ANALYSIS; DISTAL FEMUR; PROSTHESIS; BONE; OSTEOARTHRITIS; FIXATION; METAL;
D O I
10.1177/1753193416659230
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The reported outcomes of the Elektra thumb carpo-metacarpal joint implant have been very variable. This study evaluates the influence of daily cyclic loads and the type of the screw-fit cup insertion technique in the trapezium, with and without prior threading, on the structural bone behaviour. The study was performed experimentally to predict initial implant stability and cortical bone strains. Computational models were developed to assess the structural cancellous bone behaviour. The use of Elektra implant considerably changed the bone strain behaviour compared with the intact joint. This may be associated with risks of cancellous bone fatigue failure due to overload, particularly in the trapezium. The joint load magnitude has a more important structural role than that of the screw-fit cup insertion technique. Limiting the magnitude of thumb loads after arthroplasty may contribute positively to the longevity of this procedure. Level of evidence: V
引用
收藏
页码:930 / 938
页数:9
相关论文
共 42 条
  • [1] [Anonymous], 2012, F183908 ASTM INT
  • [2] Burstein A., 1994, Fundamentals of Orthopaedic Biomechanics, P191
  • [3] TRAPEZIO-METACARPAL ARTHROPLASTY BY TOTAL PROSTHESIS
    CAFFINIERE, JYDL
    AUCOUTURIER, P
    [J]. HAND, 1979, 11 (01): : 41 - 46
  • [4] A COMPARISON OF THE FATIGUE BEHAVIOR OF HUMAN TRABECULAR AND CORTICAL BONE TISSUE
    CHOI, K
    GOLDSTEIN, SA
    [J]. JOURNAL OF BIOMECHANICS, 1992, 25 (12) : 1371 - 1381
  • [5] Outcome of uncemented trapeziometacarpal prosthesis for treatment of thumb carpometacarpal joint arthritis
    Chug, Manish
    Williams, Nicole
    Benn, David
    Brindley, Stephen
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (04) : 394 - 398
  • [6] OUTCOME ANALYSIS OF TRAPEZECTOMY WITH AND WITHOUT PYROCARBON INTERPOSITION TO TREAT PRIMARY ARTHROSIS OF THE TRAPEZIOMETACARPAL JOINT
    Colegate-Stone, T. J.
    Garg, S.
    Subramanian, A.
    Mani, G. V.
    [J]. JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2011, 16 (01) : 49 - 54
  • [7] Biomechanical analysis of total elbow replacement with unlinked iBP prosthesis: An in vitro and finite element analysis
    Completo, A.
    Pereira, J.
    Fonseca, F.
    Ramos, A.
    Relvas, C.
    Simoes, J.
    [J]. CLINICAL BIOMECHANICS, 2011, 26 (10) : 990 - 997
  • [8] Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: An in vitro and finite element analysis
    Completo, A.
    Rego, A.
    Fonseca, F.
    Ramos, A.
    Relvas, C.
    Simoes, J. A.
    [J]. CLINICAL BIOMECHANICS, 2010, 25 (02) : 159 - 165
  • [9] Experimental Evaluation of Strain Shielding in Distal Femur in Revision TKA
    Completo, A.
    Simoes, J. A.
    Fonseca, F.
    [J]. EXPERIMENTAL MECHANICS, 2008, 48 (06) : 817 - 824
  • [10] BIOMECHANICAL ANALYSIS OF STATIC FORCES IN THUMB DURING HAND FUNCTION
    COONEY, WP
    CHAO, EYS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (01) : 27 - 36