Anterior Lumbar Interbody Fusion Using Reaction Bonded Silicon Nitride Implants: Long-Term Case Series of the First Synthetic Anterior Lumbar Interbody Fusion Spacer Implanted in Humans

被引:18
作者
Mobbs, Ralph J. [1 ,2 ,3 ]
Rao, Prashanth J. [1 ,2 ,3 ]
Phan, Kevin [1 ,2 ,3 ]
Hardcastle, Philip [4 ]
Choy, Wen Jie [1 ,3 ]
McCartney, Eric R. [3 ]
Druitt, Ross K. [5 ]
Mouatt, Christopher A. L. [5 ,6 ]
Sorrell, Charles C. [3 ,7 ]
机构
[1] NeuroSpine Surg Res Grp NSURG, Sydney, NSW, Australia
[2] Prince Wales Private Hosp, Sydney, NSW, Australia
[3] Univ New South Wales Sydney, Sydney, NSW, Australia
[4] Philip Hardcastle Clin, Perth, WA, Australia
[5] Sialon Ceram Pty Ltd, Doyalson North, NSW, Australia
[6] BC&M Advisory Pty Ltd, Lindfield, NSW, Australia
[7] Univ New South Wales Sydney, Sch Mat Sci & Engn, Sydney, NSW, Australia
关键词
ALIF spacer; Anterior lumbar interbody fusion; Human implantation; Intervertebral spacer; Reaction bonded Si3N4; 30 years outcome; Silicon nitride; STRUCTURAL ORTHOPEDIC IMPLANTS; RATING DEPRESSION SCALE; IN-VITRO; CERAMICS; SPINE; MICROSTRUCTURE; MICROELECTRODE; COMPLICATIONS; FABRICATION; DENSE;
D O I
10.1016/j.wneu.2018.08.237
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: In this study, a historical case series is reported of reaction bonded silicon nitride (Si3N4) implants for anterior lumbar interbody fusion (ALIF) for a patient population of 30 and surgery levels L3/4, L4/5, and/or L5/S1. Before the study, the only work on Si3N4 as a biomedical material was associated preliminary work, which involved animal trials using a rabbit model. The objective was to undertake the first use of Si3N4 as a biomedical material for humans, as an implant for ALIF. METHODS: The Si3N4 implants were prepared by die-pressing silicon powder and reaction bonding in 95 N-2/5 H-2 at similar to 1400 degrees C for similar to 50 hours. The surgeries involved a retroperitoneal approach for L3/4 and L4/5 levels and a transperitoneal approach for L5/S1 level. The patient follow-up involved assessment of radiologic fusion up to 30 years and clinical outcomes to 10 years. RESULTS: The reaction bonded Si3N4 implants were found to be biologically safe and to show high fusion rates with minimal subsidence, no abnormal reaction, and no other complications. The primary outcome measure, visual analog scale back pain, improved from a preoperative mean of 8.4 (range, 6-10) to a mean of 3.7 (range, 0-9) at 5 years and a mean of 4.9 (range, 0-9) at 10 years. The Oswestry Disability Index improved from a preoperative mean of 48 (range, 26-84) to a mean of 35 (range, 4-76) at 10 years. CONCLUSIONS: This study confirms that Si3N4 is biologically safe in the long-term, with capacity for excellent radiologic osseointegration.
引用
收藏
页码:256 / 264
页数:9
相关论文
共 59 条
[1]   Complications of iliac crest bone graft harvesting [J].
Arrington, ED ;
Smith, WJ ;
Chambers, HG ;
Bucknell, AL ;
Davino, NA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (329) :300-309
[2]  
BAGBY GW, 1988, ORTHOPEDICS, V11, P931
[3]   Orthopedic applications of silicon nitride ceramics [J].
Bal, B. S. ;
Rahaman, M. N. .
ACTA BIOMATERIALIA, 2012, 8 (08) :2889-2898
[4]  
Billotte W., 2015, BIOMEDICAL ENG HDB
[5]   Dense and near-net-shape fabrication of Si3N4 ceramics [J].
Bocanegra-Bernal, M. H. ;
Matovic, B. .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2009, 500 (1-2) :130-149
[6]   Surface modulation of silicon nitride ceramics for orthopaedic applications [J].
Bock, Ryan M. ;
McEntire, Bryan J. ;
Bal, B. Sonny ;
Rahaman, Mohamed N. ;
Boffelli, Marco ;
Pezzotti, Giuseppe .
ACTA BIOMATERIALIA, 2015, 26 :318-330
[7]   Porous silicon nitride ceramics designed for bone substitute applications [J].
Bodisova, Katarina ;
Kasiarova, Monika ;
Domanicka, Magdalena ;
Hnatko, Miroslav ;
Lences, Zoltan ;
Novakova, Zuzana Varchulova ;
Vojtassak, Jan ;
Gromosova, Sylvia ;
Sajgalik, Pavol .
CERAMICS INTERNATIONAL, 2013, 39 (07) :8355-8362
[8]   Spondylolisthesis. [J].
Capener, N .
BRITISH JOURNAL OF SURGERY, 1932, 19 (75) :374-386
[9]   ELECTROCHEMICAL PERFORMANCE, BIOCOMPATIBILITY, AND ADHESION OF NEW POLYMER MATRICES FOR SOLID-STATE ION SENSORS [J].
CHA, GS ;
LIU, D ;
MEYERHOFF, ME ;
CANTOR, HC ;
MIDGLEY, AR ;
GOLDBERG, HD ;
BROWN, RB .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1666-1672
[10]  
CROCK HV, 1982, CLIN ORTHOP RELAT R, P157