Transformer winding fault detection by vibration analysis methods

被引:60
作者
Zhou, Hong [1 ]
Hong, Kaixing [1 ]
Huang, Hai [1 ]
Zhou, Jianping [2 ]
机构
[1] Zhejiang Univ, Dept Instrumentat Sci & Engn, 38 Zheda Rd, Hangzhou 310027, Zhejiang, Peoples R China
[2] State Grid Zhejiang Elect Power Co, Hangzhou, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Transformer winding; Electromagnetic force; Vibration model; Clamping force; Winding deformation; SHORT-CIRCUIT FORCES; POWER TRANSFORMERS; EXPERIMENTAL-VERIFICATION; DYNAMIC-RESPONSE; DEFORMATIONS; FIELD; OIL;
D O I
10.1016/j.apacoust.2016.07.024
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, the vibration of power transformer windings is studied with the aim of identifying the winding structural condition. A winding vibration model coupled with electromagnetic force analysis is proposed to obtain the steady-state vibration distribution along the axial direction. During the experiment, the model was validated on a full size, 50 MVA, three phase power transformer. Good agreement was found between the measured vibrations and the vibrations that were calculated from the model developed in this study for a healthy winding. The effect of the winding clamping force on vibration is studied to assess the winding clamping state, and different types of winding deformations were simulated to extract diagnostic information. The preliminary study shows that it is feasible to predict the mechanical faults of transformer windings with the vibration method. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:136 / 146
页数:11
相关论文
共 26 条
[1]   Experimental Verification and Finite Element Analysis of Short-Circuit Electromagnetic Force for Dry-Type Transformer [J].
Ahn, Hyun-Mo ;
Oh, Yeon-Ho ;
Kim, Joong-Kyoung ;
Song, Jae-Sung ;
Hahn, Sung-Chin .
IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (02) :819-822
[2]   Transformer Frequency Response Analysis: Mathematical and Practical Approach to Interpret Mid-frequency Oscillations [J].
Bagheri, Mehdi ;
Phung, B. T. ;
Blackburn, Trevor .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) :1962-1970
[3]   Vibro-acoustic techniques to diagnose power transformers [J].
Bartoletti, C ;
Desiderio, M ;
Di Carlo, D ;
Fazio, G ;
Muzi, F ;
Sacerdoti, G ;
Salvatori, F .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) :221-229
[4]   A TRANSFORMER MODEL FOR WINDING FAULT STUDIES [J].
BASTARD, P ;
BERTRAND, P ;
MEUNIER, M .
IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (02) :690-699
[5]   THE CALCULATION OF THE MAGNETIC FIELD OF RECTANGULAR CONDUCTORS IN A CLOSED SLOT, AND ITS APPLICATION TO THE REACTANCE OF TRANSFORMER WINDINGS [J].
BILLIG, E .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1951, 98 (01) :55-64
[6]   The role of load harmonics in audible noise of electrical transformers [J].
Ertl, Michael ;
Voss, Stephan .
JOURNAL OF SOUND AND VIBRATION, 2014, 333 (08) :2253-2270
[7]   Transformer tank vibration modeling as a method of detecting winding deformations -: Part I:: Theoretical foundation [J].
García, B ;
Burgos, JC ;
Alonso, AM .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (01) :157-163
[8]  
García B, 2006, IEEE T POWER DELIVER, V21, P164, DOI 10.1109/TPWRD.2005.852275
[9]   Modal parameters identification of power transformer winding based on improved Empirical Mode Decomposition method [J].
Geng, Chao ;
Wang, Fenghua ;
Zhang, Jun ;
Jin, Zhijian .
ELECTRIC POWER SYSTEMS RESEARCH, 2014, 108 :331-339
[10]   ROTHS METHOD FOR SOLUTION OF BOUNDARY-VALUE PROBLEMS IN ELECTRICAL ENGINEERING [J].
HAMMOND, P .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1967, 114 (12) :1969-&