Development and evaluation of a loop-mediated isothermal amplification (LAMP) technique for rapid, accurate, and specific detection of Blastocystis spp. in AIDS patients

被引:3
|
作者
Badparva, Ebrahim [1 ]
Mamaghani, Amirreza Javadi [2 ]
Kheirandish, Farnaz [1 ,3 ]
Ebrahimzadeh, Farzad [4 ]
Fallahi, Shirzad [1 ,5 ]
机构
[1] Lorestan Univ Med Sci, Fac Med, Dept Med Parasitol & Mycol, Khorramabad, Iran
[2] Shahid Beheshti Univ Med Sci, Dept Parasitol & Mycol, Tehran, Iran
[3] Lorestan Univ Med Sci, Razi Herbal Med Res Ctr, Khorramabad, Iran
[4] Lorestan Univ Med Sci, Dept Biostat & Epidemiol, Khorramabad, Iran
[5] Lorestan Univ Med Sci, Hepatitis Res Ctr, Khorramabad, Iran
关键词
Accurate; AIDS patients; Blastocystis spp; LAMP; PCR; Rapid detection; PREVALENCE; HOMINIS; INDIVIDUALS; DIAGNOSIS; PARASITES;
D O I
10.1007/s15010-022-01818-7
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background Blastocystis spp. is one of the most prevalent intestinal parasites with worldwide distribution. Various diagnostic methods with different sensitivities and specificities have been used to detect Blastocystis in clinical samples. The present study aims to develop and evaluate a LAMP assay to detect Blastocystis spp. in AIDS patients for the first time. Methods In this cross-sectional study, 98 AIDS patients with an average CD4 + T lymphocyte count lower than 150 cells/mm(3) participated in the study. The presence of Blastocystis spp. in the stool samples of AIDS patients was examined by parasitology (direct wet mount and concentration assays) and molecular (PCR and LAMP) methods. The 18 SSU rRNA genomic target was used to design the specific primers for the PCR and LAMP assays. The specificity of designed primers for the LAMP assay was evaluated using the sequencing of a conventional PCR product by the external LAMP primers. The data were analyzed using the SPSS software and chi-square test and Fischer's exact tests were used and Cohen's Kappa calculates the agreement of the molecular tests. Associations were tested using odd ratios (OR) and 95% confidence intervals (CI) after adjustments. Results Out of 98 stool samples from patients with AIDS, 9 (9.18%), 13 (13.26%), and 15 (15.30%) samples were detected positive for Blastocystis spp. by parasitology, PCR, and LAMP techniques, respectively. PCR amplification and subsequent sequencing of the product sequences revealed that the obtained partial sequences were identical to the corresponding 18 SSU rRNA sequences reported in GenBank. The higher positivity rate for Blastocystis spp. among studied AIDS patients by LAMP technique compared to other diagnostic methods showed the higher potential and effectiveness of this relatively new described molecular assay for the detection of Blastocystis spp. in AIDS patients. Conclusion The accurate and rapid detection of emerging intestinal protozoa such as Blastocystis is of clinical importance for better prevention and timely treatment of the disease, especially in immunocompromised patients. The results obtained for the first time showed that the sensitivity and accuracy of the LAMP technique in the diagnosis of Blastocystis spp. in AIDS patients is very high.
引用
收藏
页码:1295 / 1302
页数:8
相关论文
共 50 条
  • [1] Development and evaluation of a loop-mediated isothermal amplification (LAMP) technique for rapid, accurate, and specific detection of Blastocystis spp. in AIDS patients
    Ebrahim Badparva
    Amirreza Javadi Mamaghani
    Farnaz Kheirandish
    Farzad Ebrahimzadeh
    Shirzad Fallahi
    Infection, 2022, 50 : 1295 - 1302
  • [2] Development and application of a rapid detection method for Clarireedia spp. using loop-mediated isothermal amplification (LAMP) assay
    Huang, Junwen
    Zhang, Wu
    Yang, Jinyu
    Huo, Pinghui
    Niu, Xueli
    TROPICAL PLANT PATHOLOGY, 2023, 48 (01) : 52 - 61
  • [3] Development of loop-mediated isothermal amplification (LAMP) for detection of Theileria equi
    Xie, Junren
    Liu, Guangyuan
    Tian, Zhancheng
    Luo, Jin
    ACTA TROPICA, 2013, 127 (03) : 245 - 250
  • [4] Development and application of a rapid detection method for Clarireedia spp. using loop-mediated isothermal amplification (LAMP) assay
    Junwen Huang
    Wu Zhang
    Jinyu Yang
    Pinghui Huo
    Xueli Niu
    Tropical Plant Pathology, 2023, 48 : 52 - 61
  • [5] Development of loop-mediated isothermal amplification (LAMP) for simple detection of Leishmania infection
    Sriworarat, Chaichontat
    Phumee, Atchara
    Mungthin, Mathirut
    Leelayoova, Saovanee
    Siriyasatien, Padet
    PARASITES & VECTORS, 2015, 8
  • [6] Loop-mediated isothermal amplification (LAMP) test for specific and rapid detection of Brucella abortus in cattle
    Karthik, K.
    Rathore, Rajesh
    Thomas, Prasad
    Arun, T. R.
    Viswas, K. N.
    Agarwal, R. K.
    Manjunathachar, H. V.
    Dhama, Kuldeep
    VETERINARY QUARTERLY, 2014, 34 (04) : 174 - 179
  • [7] Development of Loop-Mediated Isothermal Amplification (LAMP) for Universal Detection of Enteroviruses
    Zhao, Hua-Bing
    Yin, Guang-Ya
    Zhao, Guo-Ping
    Huang, Ai-Hua
    Wang, Jun-Hong
    Yang, Shuang-Feng
    Gao, Hong-Sheng
    Kang, Wei-Jun
    INDIAN JOURNAL OF MICROBIOLOGY, 2014, 54 (01) : 80 - 86
  • [8] Rapid detection of Brucella spp. by the loop-mediated isothermal amplification method
    Ohtsuki, R.
    Kawamoto, K.
    Kato, Y.
    Shah, M. M.
    Ezaki, T.
    Makino, S-I.
    JOURNAL OF APPLIED MICROBIOLOGY, 2008, 104 (06) : 1815 - 1823
  • [9] Accurate and rapid detection of Fasciola hepatica copro-DNA in sheep using loop-mediated isothermal amplification (LAMP) technique
    Amiri, Siamak
    Shemshadi, Bahar
    Shirali, Saloomeh
    Kheirandish, Farnaz
    Fallahi, Shirzad
    VETERINARY MEDICINE AND SCIENCE, 2021, 7 (04) : 1316 - 1324
  • [10] Detection of Salmonella spp. by a loop-mediated isothermal amplification (LAMP) method targeting bcfD gene
    Zhuang, L.
    Gong, J.
    Li, Q.
    Zhu, C.
    Yu, Y.
    Dou, X.
    Liu, X.
    Xu, B.
    Wang, C.
    LETTERS IN APPLIED MICROBIOLOGY, 2014, 59 (06) : 658 - 664