Comparison of Cutting Balloon Angioplasty and Percutaneous Balloon Angioplasty of Arteriovenous Fistula Stenosis: A Meta-Analysis and Systematic Review of Randomized Clinical Trials

被引:57
作者
Agarwal, Shiv Kumar [1 ]
Nadkarni, Girish N. [2 ]
Yacoub, Rabi [2 ]
Patel, Achint A. [3 ]
Jenkins, James S. [4 ]
Collins, Tyrone J. [4 ]
Annapureddy, Narender [5 ]
Kumbala, Damodar [6 ]
Bodana, Shirisha [6 ]
Benjo, Alexandre M. [4 ]
机构
[1] Univ Arkansas Med Sci, Div Cardiol, Dept Internal Med, Little Rock, AR 72205 USA
[2] Icahn Sch Med Mt Sinai, Div Nephrol, Dept Med, New York, NY 10029 USA
[3] Icahn Sch Med Mt Sinai, Dept Publ Hlth, New York, NY 10029 USA
[4] Ochsner Clin Fdn, Div Cardiol, Dept Internal Med, New Orleans, LA USA
[5] Vanderbilt Univ, Med Ctr, Dept Med, Div Rheumatol, Nashville, TN USA
[6] Ochsner Clin Fdn, Dept Internal Med, Div Nephrol, New Orleans, LA USA
关键词
RESISTANT VENOUS STENOSES; ULTRAHIGH-PRESSURE ANGIOPLASTY; PRIMARY PATENCY; HEMODIALYSIS; ACCESS; IMMEDIATE;
D O I
10.1111/joic.12202
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundHemodialysis (HD) access failure is a common cause of increased morbidity and healthcare cost in patients with end stage renal disease (ESRD). Percutaneous balloon angioplasty has been used to treat hemodialysis access stenosis but is complicated by a high rate of restenosis. Percutaneous cutting balloon (PCB) angioplasty is an alternative approach that has shown to reduce restenosis. ObjectivesThe aim of the study is to assess the safety and efficacy of PCB angioplasty in comparison with conventional and high-pressure balloon angioplasty in the treatment of hemodialysis access site stenosis. MethodsWe searched PubMed, EMBASE and the Cochrane Central register of controlled trials (CENTRAL) databases through August 2014 and selected studies using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist. We included all randomized clinical trials with a head-to-head comparison between PCB and conventional or high-pressure balloon angioplasty ResultsThree studies with 1034 participants (age 60.7 (12.9) years and 50.1% males) with 525 in PCB and 509 in control arm were included in the analysis. The immediate procedural success rate was not significantly different in the PCB angioplasty and control arm respectively, (87.2% vs. 83.7% RD -0.02; 95%CI -0.06 to 0.01; P=0.38). The six-month target lesion patency was significantly higher in the PCB angioplasty arm (67.2% vs. 55.6% RD 0.12; 95%CI 0.05-0.19; P<0.05) with number needed to treat (NNT) of 9. The device related complications were not statistically significant between groups (RD 0.03; 95%CI -0.02 to 0.07; P=0.26). ConclusionsPCB angioplasty is effective in treatment of hemodialysis access stenosis, with significantly higher six-month patency compared to balloon angioplasty. (J Interven Cardiol 2015;28:288-295)
引用
收藏
页码:288 / 295
页数:8
相关论文
共 25 条
[1]   Randomized Clinical Trial of Cutting Balloon Angioplasty versus High-Pressure Balloon Angioplasty in Hemodialysis Arteriovenous Fistula Stenoses Resistant to Conventional Balloon Angioplasty [J].
Aftab, Syed Arafat ;
Tay, Kiang Hiong ;
Irani, Farah G. ;
Lo, Richard Hoau Gong ;
Gogna, Apoorva ;
Haaland, Benjamin ;
Tan, Seck Guan ;
Chng, Slew Png ;
Pasupathy, Shanker ;
Choong, Hui Lin ;
Tan, Bien Soo .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (02) :190-198
[2]  
Albers F J, 1994, Adv Ren Replace Ther, V1, P107
[3]   Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis - Results of the Restenosis Cutting Balloon Evaluation Trial (RESCUT) [J].
Albiero, R ;
Silber, S ;
Di Mario, C ;
Cernigliaro, C ;
Battaglia, S ;
Reimers, B ;
Frasheri, A ;
Klauss, V ;
Auge, JM ;
Rubartelli, P ;
Morice, MC ;
Cremonesi, A ;
Schofer, J ;
Bortone, A ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (06) :943-949
[4]  
[Anonymous], 1997, Am J Kidney Dis, V30, pS150
[5]  
[Anonymous], CUTTING BALLOON VERS
[6]   CUTTING BALLOON - A NOVEL-APPROACH TO PERCUTANEOUS ANGIOPLASTY [J].
BARATH, P ;
FISHBEIN, MC ;
VARI, S ;
FORRESTER, JS .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (11) :1249-1252
[7]   Cutting balloon angioplasty in arteriovenous fistulas [J].
Funaki, B .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (01) :5-7
[8]  
Higgins JP., 2011, BMJ, V343, pd5928, DOI [10.1136/bmj.d5928, DOI 10.1136/BMJ.D5928]
[9]   Measuring inconsistency in meta-analyses [J].
Higgins, JPT ;
Thompson, SG ;
Deeks, JJ ;
Altman, DG .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414) :557-560
[10]   Quantifying heterogeneity in a meta-analysis [J].
Higgins, JPT ;
Thompson, SG .
STATISTICS IN MEDICINE, 2002, 21 (11) :1539-1558