Terminal Decontamination of Patient Rooms Using an Automated Mobile UV Light Unit

被引:88
作者
Boyce, John M. [1 ,2 ]
Havill, Nancy L. [1 ]
Moore, Brent A. [3 ]
机构
[1] Yale Univ, Hosp St Raphael, Sch Med, Dept Med, New Haven, CT 06511 USA
[2] Yale Univ, Dept Med, Sch Med, New Haven, CT 06511 USA
[3] Yale Univ, Dept Psychiat, Sch Med, New Haven, CT 06511 USA
关键词
VANCOMYCIN-RESISTANT ENTEROCOCCI; DIFFICILE-ASSOCIATED DISEASE; HYDROGEN-PEROXIDE VAPOR; CLOSTRIDIUM-DIFFICILE; ENVIRONMENTAL CONTAMINATION; ACQUISITION; SURFACES; RISK; TRANSMISSION; RADIATION;
D O I
10.1086/661222
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
OBJECTIVE. To determine the ability of a mobile UV light unit to reduce bacterial contamination of environmental surfaces in patient rooms. METHODS. An automated mobile UV light unit that emits UV-C light was placed in 25 patient rooms after patient discharge and operated using a 1- or 2-stage procedure. Aerobic colony counts were calculated for each of 5 standardized high-touch surfaces in the rooms before and after UV light decontamination (UVLD). Clostridium difficile spore log reductions achieved were determined using a modification of the ASTM (American Society for Testing and Materials) International E2197 quantitative disk carrier test method. In-room ozone concentrations during UVLD were measured. RESULTS. For the 1-stage procedure, mean aerobic colony counts for the 5 high-touch surfaces ranged from 10.6 to 98.2 colony-forming units (CFUs) per Dey/Engley (D/E) plate before UVLD and from 0.3 to 24.0 CFUs per D/E plate after UVLD, with significant reductions for all 5 surfaces (all P < .02). Surfaces in direct line of sight were significantly more likely to yield negative culture results after UVLD than before UVLD (all P < .001). Mean C. difficile spore log reductions ranged from 1.8 to 2.9. UVLD cycle times ranged from 34.2 to 100.1 minutes. For the 2-stage procedure, mean aerobic colony counts ranged from 10.0 to 89.2 CFUs per D/E plate before UVLD and were 0 CFUs per D/E plate after UVLD, with significant reductions for all 5 high-touch surfaces. UVLD cycle times ranged from 72.1 to 146.3 minutes. In-room ozone concentrations during UVLD ranged from undetectable to 0.012 ppm. CONCLUSIONS. The mobile UV-C light unit significantly reduced aerobic colony counts and C. difficile spores on contaminated surfaces in patient rooms. Infect Control Hosp Epidemiol 2011; 32(8): 737-742
引用
收藏
页码:737 / 742
页数:6
相关论文
共 24 条
[1]  
[Anonymous], 2008, Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008
[2]  
[Anonymous], 2003, MMWR-MORBID MORTAL W, V52, P1
[3]  
*ASTM INT, 2007, STAND QUANT DISK CAR
[4]   Clostridium difficile skin contamination in patients with C-difficile-associated disease [J].
Bobulsky, Greg S. ;
Al-Nassir, Wafa N. ;
Riggs, Michelle M. ;
Sethi, Ajay K. ;
Donskey, Curtis J. .
CLINICAL INFECTIOUS DISEASES, 2008, 46 (03) :447-450
[5]   Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a Healthcare setting [J].
Boyce, John M. ;
Havill, Nancy L. ;
Otter, Jonathan A. ;
McDonald, L. Clifford ;
Adams, Nicholas M. T. ;
Cooper, Timothea ;
Thompson, Angela ;
Wiggs, Lois ;
Killgore, George ;
Tauman, Allison ;
Noble-Wang, Judith .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2008, 29 (08) :723-729
[6]   Monitoring the Effectiveness of Hospital Cleaning Practices by Use of an Adenosine Triphosphate Bioluminescence Assay [J].
Boyce, John M. ;
Havill, Nancy L. ;
Dumigan, Diane G. ;
Golebiewski, Michael ;
Balogun, Ola ;
Rizvani, Ramo .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2009, 30 (07) :678-684
[7]   Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals [J].
Carling, P. C. ;
Parry, M. F. ;
Von Beheren, S. M. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2008, 29 (01) :1-7
[8]   Improved cleaning of patient rooms using a new targeting method [J].
Carling, PC ;
Briggs, JL ;
Perkins, J ;
Highlander, D .
CLINICAL INFECTIOUS DISEASES, 2006, 42 (03) :385-388
[9]   The role of environmental cleaning in the control of hospital-acquired infection [J].
Dancer, S. J. .
JOURNAL OF HOSPITAL INFECTION, 2009, 73 (04) :378-385
[10]   Monitoring environmental cleanliness on two surgical wards [J].
Dancer, Stephanie J. ;
White, Liza ;
Robertson, Chris .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2008, 18 (05) :357-364