An Innovative Approach to Reduce Streaking Artifacts in FDK Based 3D Cone-beam Tomography

被引:0
作者
Bhowmik, Ujjal Kumar [1 ]
Sudeepth, Araveti Venkata [1 ]
Adhami, Reza R. [1 ]
机构
[1] Univ Alabama, Dept Elect & Comp Engn, Huntsville, AL 35899 USA
来源
IEEE SOUTHEASTCON 2011: BUILDING GLOBAL ENGINEERS | 2011年
关键词
RECONSTRUCTION; ALGORITHM; CT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we propose a method to detect and eliminate the streaking artifacts, present in Feldkamp-David-Kress (FDK) based 3D cone-beam tomography, by comparing and combining two synthetic data sets. The data sets, which are 3D reconstructed volume data, are created from the original and negative of the X-ray projections of 3D Sheep-Logan model. The 2(nd) data set, created from the negative of the projections, has minimized streaking artifacts originated from high intensity region. However, it loses the bone structure information, so the original data set, where the streaking artifact is evident, is combined with the 2(nd) data set to recover bone structure information. The simulation results show a significant reduction of streaking artifact is achieved.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 10 条
  • [1] Dean S.R., 1993, The Radon Transform and Some of its Application
  • [2] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [3] Hsieh J., 2002, COMPUTED TOMOGRAPHY
  • [4] Kak A.C., 1999, Principle of Tomographic Imaging
  • [5] Streaking artifacts reduction in four-dimensional cone-beam computed tomography
    Leng, Shuai
    Zambelli, Joseph
    Tolakanahalli, Ranjini
    Nett, Brian
    Munro, Peter
    Star-Lack, Joshua
    Paliwal, Bhudatt
    Chena, Guang-Hong
    [J]. MEDICAL PHYSICS, 2008, 35 (10) : 4649 - 4659
  • [6] OPTIMAL SHORT SCAN CONVOLUTION RECONSTRUCTION FOR FANBEAM CT
    PARKER, DL
    [J]. MEDICAL PHYSICS, 1982, 9 (02) : 254 - 257
  • [7] Rezvani N., 2007, An Open Source Cone-Beam CT Reconstruction Tool for Imaging Research
  • [8] Sun F., 2008, INT C BIOM ENG INF
  • [9] A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory
    Tang, XY
    Hsieh, J
    Hagiwara, A
    Nilsen, RA
    Thibault, JB
    Drapkin, E
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16) : 3889 - 3905
  • [10] Zhu JH, 2004, J X-RAY SCI TECHNOL, V12, P215