Dosimetric evaluation of two phases of respiratory movement using a lung equivalent material for radiotherapy treatment planning

被引:0
作者
Inal, Aysun [1 ]
机构
[1] Antalya Training & Res Hosp, Dept Radiat Oncol, Antalya, Turkey
关键词
radiotherapy; cork; dosimetry; lung phantom; respiratory phase; QUALITY-ASSURANCE; CT; IMPACT; VERIFICATION; CONVERSION; IMRT;
D O I
10.1017/S1460396919000505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background/aim: Radiation dosimetry requires special phantoms which are comparable with organs and tissues of a human body. The lung is one of the organs with a low density. Therefore, it is important to create and use lung equivalent phantoms in dosimetric controls. The aim of this study was to investigate the importance of using lung equivalent phantoms for different respiratory phases during measurements with both computed tomography (CT) and linear accelerator. Materials and methods: The maximum lung inhalation phantom (LIP) and lung exhalation phantom (LEP) were created for two respiratory phases. The Hounsfield Unit (HU) values based on the selected slice thickness and CT tube voltages were investigated, as well as the difference between energy and algorithms used in the treatment planning system. Results: It was found that the change in HU values according to slice thickness were more significant in measurements for respiratory phases. The dose difference between LEP and LIP at a point which is located 1 cm below the surface of the phantoms was found as 1 center dot 0% for 6 megavolt (MV) and 2 center dot 8% for 18 MV. The highest difference between the two algorithms was found to be 7 center dot 22% for 6 MV and 10 center dot 93% for 18 MV for LIP phantom. Conclusion: It can be said that the LIP and LEP phantoms prepared in accordance with respiratory phases can be a simple and inexpensive method to investigate any difference in dosimetry during respiratory phases. Also, measured and calculated dose values are in good agreement when thinner slice thickness was chosen.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 23 条
[1]   The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumour coverage [J].
Aarup, Lasse Rye ;
Nahum, Alan E. ;
Zacharatou, Christina ;
Juhler-Nottrup, Trine ;
Knoos, Tommy ;
Nystrom, Hakan ;
Specht, Lena ;
Wieslander, Elinore ;
Korreman, Stine S. .
RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) :405-414
[2]   Beam modeling and verification of a photon beam multisource model [J].
Ahnesjö, A ;
Weber, L ;
Murman, A ;
Saxner, M ;
Thorslund, I ;
Traneus, E .
MEDICAL PHYSICS, 2005, 32 (06) :1722-1737
[3]   The dosimetric effects of tissue heterogeneities in intensity-modulated radiation therapy (IMRT) of the head and neck [J].
Al-Hallaq, HA ;
Reft, CS ;
Roeske, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (05) :1145-1156
[4]  
BATHO H F, 1964, J Can Assoc Radiol, V15, P79
[5]   A Comparison of physical and dosimetric properties of lung substitute materials [J].
Chang, Kwo-Ping ;
Hung, Shang-Ho ;
Chie, Yu-Huang ;
Shiau, An-Cheng ;
Huang, Ruey-Jing .
MEDICAL PHYSICS, 2012, 39 (04) :2013-2020
[6]   Dosimetric impact of computed tomography calibration on a commercial treatment planning system for external radiation therapy [J].
Cozzi, L ;
Fogliata, A ;
Buffa, F ;
Bieri, S .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) :335-338
[7]   CT-ED conversion on a GE Lightspeed-RT scanner: influence of scanner settings [J].
Ebert, M. A. ;
Lambert, J. ;
Greer, P. B. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2008, 31 (02) :154-159
[8]   American Association of Physicists in Medicine radiation therapy committee task group 53: Quality assurance for clinical radiotherapy treatment planning [J].
Fraass, B ;
Doppke, K ;
Hunt, M ;
Kutcher, G ;
Starkschall, G ;
Stern, R ;
Van Dyke, J .
MEDICAL PHYSICS, 1998, 25 (10) :1773-1829
[9]   CT number variations due to different image acquisition and reconstruction parameters: a thorax phantom study [J].
Groell, R ;
Rienmueller, R ;
Schaffler, GJ ;
Portugaller, HR ;
Graif, E ;
Willfurth, P .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2000, 24 (02) :53-58
[10]   Accuracy of inhomogeneity correction in photon radiotherapy from CT scans with different settings [J].
Guan, HQ ;
Yin, FF ;
Kim, JH .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (17) :N223-N231