Augmentation of Pedicle Screw Stability With Calcium Sulfate Cement in Osteoporotic Sheep Biomechanical and Screw-bone Interfacial Evaluation

被引:27
作者
Liu, Da [1 ]
Lei, Wei [1 ]
Wu, Zi-xiang [1 ]
Gao, Ming-xuan [1 ]
Wan, Shi-yong [1 ]
Fu, Suo-chao [1 ]
Shi, Lei [1 ]
机构
[1] Fourth Mil Med Univ, Inst Orthopaed, Xijing Hosp, Xian 710032, Shaanxi Prov, Peoples R China
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2011年 / 24卷 / 04期
基金
国家高技术研究发展计划(863计划);
关键词
pedicle screw; calcium sulfate cement; osteoporosis; in vivo; micro-CT; biomechanics; PULLOUT STRENGTH; FIXATION STRENGTH; MINERAL DENSITY; INSTRUMENTATION; INJECTION; PHOSPHATE; SPINES; MODEL;
D O I
10.1097/BSD.0b013e3181ecf88a
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: Augmentation of pedicle screws with calcium sulfate cement (CSC) was performed in osteoporotic sheep. Biomechanical tests, micro-computed tomography (CT) analysis, and histological observation were performed. Objective: To investigate the long-term biomechanical performance of pedicle screws augmented with CSC in vivo and evaluated the screw-bone interfacial bonding with micro-CT and histological techniques. Summary of Background Data: There is little information on the long-term biomechanical performance and screw-bone interfacial bonding of pedicle screws augmented with CSC in osteoporosis in vivo. Methods: Twelve months after ovariectomy, bilateral pedicles of lumbar vertebrae (L1 to L5) of 6 female sheep were fixed with pedicle screws. One pedicle of each vertebral body was treated with a screw augmented with CSC (CSC group) and the contralateral pedicle was treated with a screw without any augmentation (control group). Three months later, the sheep were killed and biomechanical tests, micro-CT analysis, and histological observation were conducted on the isolated specimen vertebrae. Results: Twelve months after ovariectomy, animal model of osteoporosis was established successfully. Both the axial and vertical stabilities of the pedicle screws in CSC group were significantly enhanced compared with those in the control group (P < 0.05). Micro-CT reconstruction and analysis showed that there were more bone trabeculae around the screws in CSC group compared with those in control group (P < 0.05), and the bone trabeculae were significantly denser than those in control group (P < 0.05). Histological observation showed that CSC was completely degradated and bone trabeculae around the screws in CSC group were more and denser than that in the control group. Bone trabeculae held the screws tightly without any interspaces between screw and bone, which formed strong bonding between bone and screw. Conclusions: CSC can significantly improve screw-bone interfacial bonding and strengthen the long-term stability of pedicle screws in osteoporotic sheep. Augmentation with CSC may be a potentially useful method to increase the stability of pedicle screws in patients with osteoporosis.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 26 条
[1]   Assessment of different screw augmentation techniques and screw designs in osteoporotic spines [J].
Becker, S. ;
Chavanne, A. ;
Spitaler, R. ;
Kropik, K. ;
Aigner, N. ;
Ogon, M. ;
Redl, H. .
EUROPEAN SPINE JOURNAL, 2008, 17 (11) :1462-1469
[2]   Primary pedicle screw augmentation in osteoporotic lumbar vertebrae - Biomechanical analysis of pedicle fixation strength [J].
Burval, Daniel J. ;
McLain, Robert F. ;
Milks, Ryan ;
Inceoglu, Serkan .
SPINE, 2007, 32 (10) :1077-1083
[3]   Biomechanical comparison of anatomic trajectory pedicle screw versus injectable calcium sulfate graft-augmented pedicle screw for salvage in cadaveric thoracic bone [J].
Derincek, A ;
Wu, C ;
Mehbod, A ;
Transfeldt, EE .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (04) :286-291
[4]   Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant - Technical note and report of three case [J].
Fransen, Patrick .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (03) :366-369
[5]   The use of pedicle-screw internal fixation for the operative treatment of spinal disorders [J].
Gaines, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) :1458-1476
[6]   EFFECTS OF BONE-MINERAL DENSITY ON PEDICLE SCREW FIXATION [J].
HALVORSON, TL ;
KELLEY, LA ;
THOMAS, KA ;
WHITECLOUD, TS ;
COOK, SD .
SPINE, 1994, 19 (21) :2415-2420
[7]   Pullout strength of pedicle screws augmented with particulate calcium phosphate: An experimental study [J].
Hashemi, Ata ;
Bednar, Drew ;
Ziada, Samir .
SPINE JOURNAL, 2009, 9 (05) :404-410
[8]   Comparison of segmental pedicle screw instrumentation versus anterior instrumentation in adolescent idiopathic thoracolumbar and lumbar scoliosis [J].
Hee, Hwan-Tak ;
Yu, Zhi-Rong ;
Wong, Hee-Kit .
SPINE, 2007, 32 (14) :1533-1542
[9]   Biomechanical Analysis of Different Techniques in Revision Spinal Instrumentation Larger Diameter Screws Versus Cement Augmentation [J].
Kiner, Dirk W. ;
Wybo, Christopher D. ;
Sterba, William ;
Yeni, Yener N. ;
Bartol, Stephen W. ;
Vaidya, Rahul .
SPINE, 2008, 33 (24) :2618-2622
[10]  
Konno S, 1994, Eur Spine J, V3, P299, DOI 10.1007/BF02200140