Electrochemical Sensor for Dapsone Using Molecularly Imprinted Polypyrrole Membrane as a Recognition Element

被引:15
作者
Afkhami, Abbas [1 ]
Gomar, Fatemeh [1 ]
Madrakian, Tayyebeh [1 ]
机构
[1] Bu Ali Sina Univ, Fac Chem, Hamadan, Iran
关键词
POLYMERS; ELECTRODE;
D O I
10.1149/2.0391506jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
An electrochemical sensor based on molecularly imprinted polypyrrole membrane is reported for the determination of dapsone (DDS). The sensor was prepared by electropolymerization of pyrrole at a glassy carbon electrode in the presence of DDS as a template. The electropolymerization was performed in the presence of an aqueous solution of 0.1 M HCl, and 0.2 M pyrrole, with and without a template molecule (DDS) at a glassy carbon electrode using cyclic voltammetry. Some of the parameters, important to controlling the performance of the polypyrrole, were investigated and optimized, including the effects of pH, monomer and template concentrations, electropolymerization cycles. The molecularly imprinted film exhibited a high selectivity and sensitivity toward dapsone. The differential pulse voltammetry (DPV) peak current showed a linear dependence on the DDS concentration and a linear calibration curve was obtained in the range 1.0 mu M to 110 mu M of DDS with a correlation coefficient of 0.998 with a detection limit of 3.0 x 10(-7) M (S/N = 3). The electrode was successfully applied to the determine Dapsone in spiked human serum and urine. (C) 2015 The Electrochemical Society. All rights reserved.
引用
收藏
页码:B109 / B113
页数:5
相关论文
共 21 条
[11]   Electroanalysis of dapsone, an anti-leprotic drug [J].
Manisankar, P ;
Sarpudeen, A ;
Viswanathan, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (5-6) :873-881
[12]   Parathion sensor based on molecularly imprinted sol-gel films [J].
Marx, S ;
Zaltsman, A ;
Turyan, I ;
Mandler, D .
ANALYTICAL CHEMISTRY, 2004, 76 (01) :120-126
[13]   ANALYSIS OF DRUGS BY POLAROGRAPHIC METHODS .26. POLAROGRAPHIC-DETERMINATION (DPP) OF THE ANTILEPROSY AGENT DIAPHENYLSULFONE [J].
OELSCHLAGER, H ;
MODRACK, G .
ARCHIV DER PHARMAZIE, 1986, 319 (01) :10-14
[14]   Electrochemical preparation of a molecularly imprinted polypyrrole-modified pencil graphite electrode for determination of ascorbic acid [J].
Oezcan, Levent ;
Sahin, Mutlu ;
Sahin, Yuecel .
SENSORS, 2008, 8 (09) :5792-5805
[15]  
Reddy P. R. K., 1998, Indian Journal of Pharmaceutical Sciences, V60, P306
[16]  
SANE RT, 1982, IND DRUGS, V19, P198
[17]  
SANGHAVI NM, 1983, INDIAN DRUGS, V20, P341
[18]  
Sharma D. K., 1998, INDIAN J PHARM SCI, V60, P315
[19]   Amperometric detection of bilirubin from a micro-sensing electrode with a synthetic bilirubin imprinted poly(MAA-co-EGDMA) film [J].
Syu, Mei-Jywan ;
Chiu, Tsung-Chieh ;
Lai, Chune-You ;
Chang, Yong-Sheun .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (04) :550-557
[20]  
Van-Ritter C., 1989, GASTRO ENTEROLOGY, V96, P811