Clinical outcomes in unselected patients treated with the PROMUS Element platinum-chromium, everolimus-eluting stent: Final five-year results from the PE PROVE Study

被引:2
作者
Moreno, Raul [1 ]
Legrand, Victor [2 ]
Ferrario, Maurizio [3 ]
MacCarthy, Philip [4 ]
Redwood, Simon [5 ]
Werner, Nikos [6 ]
Jung, Werner [7 ]
Ungi, Imre [8 ]
Zaman, Azfar [9 ,10 ]
Richardt, Gert [11 ]
Crowley, James [12 ]
Schwimmbeck, Peter [13 ]
Christen, Thomas [14 ]
Allocco, Dominic J. [14 ]
Meredith, Ian T. [14 ]
机构
[1] Hosp La Paz, Madrid, Spain
[2] Ctr Hosp Univ Sart Tilman, Liege, Belgium
[3] IRCCS Policlin San Matteo, Pavia, Italy
[4] Kings Coll Hosp London, London, England
[5] Guys & St Thomas Natl Hlth Serv Fdn Trust, London, England
[6] Univ Klinikum Bonn, Bonn, Germany
[7] Schwarzwald Baar Klinikum Villingen Schwenningen, Villingen Schwenningen, Germany
[8] Szegedi Tud Egyet, Szeged, Hungary
[9] Newcastle Univ, Freeman Hosp, Newcastle Upon Tyne, Tyne & Wear, England
[10] Newcastle Univ, Inst Cellular Med, Newcastle Upon Tyne, Tyne & Wear, England
[11] Herzzentrum Segeberger Kliniken, Bad Segeberger, Germany
[12] Galway Univ Hosp, Galway, Ireland
[13] Klinikum Leverkusen, Leverkusen, Germany
[14] Boston Sci Corp, Marlborough, MA USA
关键词
coronary artery disease; drug-eluting stent; post-market surveillance study; BARE-METAL STENTS; LONG-TERM SAFETY; EFFICACY; METAANALYSIS; THROMBOSIS;
D O I
10.1002/ccd.27835
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The goal of this analysis was to evaluate the final 5-year safety and effectiveness of the PROMUS Element platinum-chromium everolimus-eluting stent in unselected patients treated in routine clinical practice. Background The prospective, open-label PROMUS Element (TM) European Post-Approval Surveillance Study (PE-PROVE) enrolled 1,010 "real-world" patients who received the PROMUS Element stent. Adverse event rates were low at 1-year, and the incidence of stent thrombosis was 0.6%. Methods The primary endpoint was target vessel failure (TVF; overall and PE stent-related), a composite of cardiac death, myocardial infarction (MI) related to the target vessel, or target vessel revascularization (TVR) at 1-year post-implantation. Five-year clinical outcomes were evaluated in overall as well as high-risk patient subgroups. Results The overall 5-year TVF rate was 14.9%, with 7.0% being related to the study stent. Cardiac death, MI and TVR related to the study stent occurred in 0.5%, 3.2%, and 5.7%, respectively. Stent thrombosis through 5-year follow-up was 1.0%. The rates of overall and study stent related TVF were numerically higher in patients with medically treated diabetes, long lesions (>= 28 mm), and small diameter vessels (<= 2.5 mm) compared to the overall study population. Additionally, favorable stent thrombosis rates through 5 years were reported for the PROMUS Element stent in these high-risk subgroups. Conclusions The final 5-year data from the PE-PROVE study demonstrate favorable outcomes and low rates of adverse events with the PE stent when used in "real-world" patients with coronary artery disease.
引用
收藏
页码:398 / 403
页数:6
相关论文
共 17 条
[1]   Comparison of Zotarolimus- and Everolimus-Eluting Coronary Stents Final 5-Year Report of the RESOLUTE All-Comers Trial [J].
Iqbal, Javaid ;
Serruys, Patrick W. ;
Silber, Sigmund ;
Kelbaek, Henning ;
Richardt, Gert ;
Morel, Marie-Angele ;
Negoita, Manuela ;
Buszman, Pawel E. ;
Windecker, Stephan .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (06)
[2]   Safety and Efficacy of Everolimus-Versus Sirolimus-Eluting Stents 5-Year Results From SORT OUT IV [J].
Jensen, Lisette Okkels ;
Thayssen, Per ;
Christiansen, Evald Hoj ;
Maeng, Michael ;
Ravkilde, Jan ;
Hansen, Knud Norregaard ;
Hansen, Henrik Steen ;
Krusell, Lars ;
Kaltoft, Anne ;
Tilsted, Hans Henrik ;
Berencsi, Klara ;
Junker, Anders ;
Lassen, Jens Flensted .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (07) :751-762
[3]   Long-Term Safety and Efficacy of Platinum Chromium Everolimus-Eluting Stents in Coronary Artery Disease 5-Year Results From the PLATINUM Trial [J].
Kelly, Christopher R. ;
Teirstein, Paul S. ;
Meredith, Ian T. ;
Farah, Bruno ;
Dubois, Christophe L. ;
Feldman, Robert L. ;
Dens, Joseph ;
Hagiwara, Nobuhisa ;
Rabinowitz, Abram ;
Carrie, Didier ;
Pompili, Vincent ;
Bouchard, Alain ;
Saito, Shigeru ;
Allocco, Dominic J. ;
Dawkins, Keith D. ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (23) :2392-2400
[4]   Incidence and Characteristics of Late Catch-Up Phenomenon Between Sirolimus-Eluting Stent and Everolimus-Eluting Stent: A Propensity Matched Study [J].
Kobayashi, Norihiro ;
Ito, Yoshiaki ;
Nakano, Masatsugu ;
Araki, Motoharu ;
Hirano, Keisuke ;
Yamawaki, Masahiro ;
Takimura, Hideyuki ;
Sakamoto, Yasunari ;
Tsukahara, Reiko ;
Muramatsu, Toshiya .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2015, 28 (06) :551-562
[5]  
Levine GN, 2011, CIRCULATION, V124, pE574, DOI 10.1161/CIR.0b013e31823ba622
[6]   The Platinum Chromium Element Stent Platform: from Alloy, to Design, to Clinical Practice [J].
Menown, Ian B. A. ;
Noad, Rebecca ;
Garcia, Eulogio J. ;
Meredith, Ian .
ADVANCES IN THERAPY, 2010, 27 (03) :129-141
[7]   Efficacy and safety of platinum-chromium everolimus-eluting stents compared with other second-generation drug-eluting stents. Meta-analysis from 5 randomized trials including 7,896 patients [J].
Moreno, Raul ;
Kim, Hyo-Soo ;
von Birgelen, Clemens ;
Stone, Gregg W. ;
Park, Seung-Jung ;
Hernandez, Jose M. De la Torre ;
Qureshi, Katie ;
Dawkins, Keith D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) :B224-B224
[8]   Long-Term Safety of Drug-Eluting and Bare-Metal Stents Evidence From a Comprehensive Network Meta-Analysis [J].
Palmerini, Tullio ;
Benedetto, Umberto ;
Biondi-Zoccai, Giuseppe ;
Della Riva, Diego ;
Bacchi-Reggiani, Letizia ;
Smits, Pieter C. ;
Vlachojannis, Georgios J. ;
Jensen, Lisette Okkels ;
Christiansen, Evald H. ;
Berencsi, Klara ;
Valgimigli, Marco ;
Orlandi, Carlotta ;
Petrou, Mario ;
Rapezzi, Claudio ;
Stone, Gregg W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (23) :2496-2507
[9]   Stent Thrombosis With Everolimus-Eluting Stents Meta-Analysis of Comparative Randomized Controlled Trials [J].
Palmerini, Tullio ;
Kirtane, Ajay J. ;
Serruys, Patrick W. ;
Smits, Pieter C. ;
Kedhi, Elvin ;
Kereiakes, Dean ;
Sangiorgi, Diego ;
Reggiani, Letizia Bacchi ;
Kaiser, Christoph ;
Kim, Hyo-Soo ;
De Waha, Antoinette ;
Ribichini, Flavio ;
Stone, Gregg W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (03) :357-364
[10]   Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis [J].
Palmerini, Tullio ;
Biondi-Zoccai, Giuseppe ;
Della Riva, Diego ;
Stettler, Christoph ;
Sangiorgi, Diego ;
D'Ascenzo, Fabrizio ;
Kimura, Takeshi ;
Briguori, Carlo ;
Sabate, Manel ;
Kim, Hyo-Soo ;
De Waha, Antoinette ;
Kedhi, Elvin ;
Smits, Pieter C. ;
Kaiser, Christoph ;
Sardella, Gennaro ;
Marullo, Antonino ;
Kirtane, Ajay J. ;
Leon, Martin B. ;
Stone, Gregg W. .
LANCET, 2012, 379 (9824) :1393-1402