A Noise Adaptive Method for Needle Localization in 3D Ultrasound Images

被引:0
作者
Malekian, Leila [1 ]
Talebi, Heidar Ali [1 ]
Towhidkhah, Farzad [1 ]
机构
[1] Amirkabir Univ Technol, Tehran, Iran
来源
2014 IRANIAN CONFERENCE ON INTELLIGENT SYSTEMS (ICIS) | 2014年
关键词
PARALLEL INTEGRAL PROJECTION; STRAIGHT ELECTRODE; TOOL LOCALIZATION; SEGMENTATION; TRACKING;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
intra-operative ultrasound imaging is a widely used technique for navigation of many minimally invasive medical procedures. Using the ultrasound imaging has advantages such as safety, speed and low cost in expense of low quality of the image due to the speckle noise. In this paper, we describe two techniques for increasing the needle localization accuracy in high and low noise levels of the 3D ultrasound images. The level of the speckle noise in the input image is estimated using the patch based noise estimation method. In low noise levels we used the maximum likelihood criteria for model evaluation step of the fitting procedure. In high noise levels, the image is filtered before thresholding, using eigenanalysis of the Hessian matrix. The results show improvement in accuracy and speed with respect to the previous model fitting RANSAC based method.
引用
收藏
页数:5
相关论文
共 25 条
  • [1] A NEW SCHEME FOR CURVED NEEDLE SEGMENTATION IN THREE-DIMENSIONAL ULTRASOUND IMAGES
    Aboofazeli, Mohammad
    Abolmaesumi, Purang
    Mousavi, Parvin
    Fichtinger, Gabor
    [J]. 2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 1067 - 1070
  • [2] Adebar Troy K., 2013, Information Processing in Computer-Assisted Interventions. Proceedings of 4th International Conference (IPCAI 2013): LNCS 7915, P61, DOI 10.1007/978-3-642-38568-1_7
  • [3] Parallel Integral Projection transform for straight electrode localization in 3-D ultrasound images
    Barva, Martin
    Uhercik, Marian
    Mari, Jean-Martin
    Kybic, Jan
    Duhamel, Jean-Rene
    Liebgott, Herve
    Hlavac, Vaclav
    Cachard, Christian
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (07) : 1559 - 1569
  • [4] Cao KL, 2013, I S BIOMED IMAGING, P37
  • [5] Chatelain P, 2013, IEEE INT CONF ROBOT, P1676, DOI 10.1109/ICRA.2013.6630795
  • [6] Automatic needle segmentation in three-dimensional ultrasound images using two orthogonal two-dimensional image projections
    Ding, MY
    Cardinal, HN
    Fenster, A
    [J]. MEDICAL PHYSICS, 2003, 30 (02) : 222 - 234
  • [7] Automatic needle segmentation in 3D ultrasound images
    Ding, MY
    Cardinal, HN
    Guan, WG
    Fenster, A
    [J]. MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 : 65 - 76
  • [8] Felber M., 2002, THESIS SWISS FEDERAL
  • [9] RANDOM SAMPLE CONSENSUS - A PARADIGM FOR MODEL-FITTING WITH APPLICATIONS TO IMAGE-ANALYSIS AND AUTOMATED CARTOGRAPHY
    FISCHLER, MA
    BOLLES, RC
    [J]. COMMUNICATIONS OF THE ACM, 1981, 24 (06) : 381 - 395
  • [10] Frangi AF, 1998, LECT NOTES COMPUT SC, V1496, P130, DOI 10.1007/BFb0056195