摘要
Consistent presentation of digital radiographic images at all locations within a medical center can help ensure a high level of patient care. Currently, liquid crystal displays (LCDs) are the electronic display technology of choice for viewing medical images. As the inherent luminance (and thereby perceived contrast) properties of different LCDs can vary substantially, calibration of the luminance response of these displays is required to ensure that observer perception of an image is consistent on all displays. The digital imaging and communication in medicine (DICOM) grayscale standard display function (GSDF) defines the luminance response of a display such that an observer's perception of image contrast is consistent throughout the pixel value range of a displayed image. The main purpose of this work is to review the theoretical and practical aspects of calibration of LCDs to the GSDF. Included herein is a review of LCD technology, principles of calibration, and other practical aspects related to calibration and observer perception of images presented on LCDs. Both grayscale and color displays are considered, and the influence of ambient light on calibration and perception is discussed.
引用
收藏
页码:193 / 207
页数:15
相关论文
共 27 条
[1]   Goniometric and conoscopic measurements of angular display contrast for one-, three-, five-, and nine-million-pixel medical liquid crystal displays [J].
Badano, A ;
Fifadara, DH .
MEDICAL PHYSICS, 2004, 31 (12) :3452-3460
[2]   Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays [J].
Badano, A ;
Flynn, MJ ;
Martin, S ;
Kanicki, J .
MEDICAL PHYSICS, 2003, 30 (10) :2602-2613
[3]  
Barten P. G. J., 1999, CONTRAST SENSITIVITY
[4]   Practical aspects of grayscale calibration of display systems [J].
Blume, H ;
Ho, AMK ;
Stevens, F ;
Steven, PM .
MEDICAL IMAGING 2001: PACS AND INTEGRATED MEDICAL INFORMATION SYSTEMS: DESIGN AND EVALUATION, 2001, 4323 :28-41
[5]   Characterization of high-resolution liquid-crystal displays for medical images [J].
Blume, H ;
Steven, PM ;
Cobb, M ;
Ho, AM ;
Stevens, F ;
Muller, S ;
Roehrig, H ;
Fan, JH .
MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 :271-292
[6]   The ACR/NEMA proposal for a grey-scale display function standard [J].
Blume, H .
IMAGE DISPLAY: MEDICAL IMAGING 1996, 1996, 2707 :344-360
[7]  
BLUME H, 2003, SPIE, V5029, P449
[8]  
BLUME H, 1990, SPIE, V1232, P97
[9]   Increasing contrast resolution and decreasing spatial noise for liquid-crystal displays using digital dithering [J].
Fan, JH ;
Roehrig, H ;
Sundareshan, MK ;
Dallas, WJ ;
Krupinski, L .
Medical Imaging 2005: Visualization, Image-Guided Procedures, and Display, Pts 1 and 2, 2005, 5744 :251-262
[10]   A photographic technique for assessing the viewing-angle performance of liquid-crystal displays [J].
Fetterly, Kenneth A. ;
Samei, Ehsan .
JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2006, 14 (10-12) :867-872