A comprehensive exergy analysis of a prototype Peltier air-cooler; experimental investigation

被引:33
作者
Dizaji, Hamed Sadighi [1 ]
Jafarmadar, Samad [1 ]
Khalilarya, Shahram [1 ]
Pourhedayat, Samira [1 ]
机构
[1] Urmia Univ, Dept Mech Engn, Orumiyeh, Iran
关键词
Thermoelectric; Cooling; Coefficient of performance; Air cooler; Peltier; WASTE HEAT-RECOVERY; THERMOELECTRIC GENERATOR; PERFORMANCE ANALYSIS; OPTIMIZATION; DESIGN; SYSTEM; WATER; SINK; CONDITIONER; EXCHANGER;
D O I
10.1016/j.renene.2018.07.056
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Thermoelectric coolers have been abundantly investigated from the viewpoint of the first law of thermodynamic. However, extremely few exergy analysis have been probed for thermoelectric air-coolers. Because of the importance of exergy consideration in each thermodynamic process, this paper experimentally focuses on the effect of various parameters on exergy destruction and the second law performance through a thermoelectric air cooler. The effects of flow and thermodynamic parameters including air flow rate, incoming air temperature, water flow rate, incoming water temperature, DC voltage/ampere etc. on exergetic characteristics are clarified in this study. Interesting meaningful curve behavior was observed for exergetic performance of thermoelectric cooler. Indeed, curve behavior of exergetic performance is descending-ascending and therefore a critical value of DC voltage was found in which the amount of second law performance has a minimum/maximum value. Increment of air flow rate improved the exergetic performance of Peltier-air cooler. Besides, higher air inlet temperature reduced exergy destruction of thermoelectric module (TEM) which means that Peltier air cooler is appropriate for regions with warmer weather in comparison with moderate climates. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:308 / 317
页数:10
相关论文
共 48 条
  • [1] Theoretical and Experimental Investigations of Solar-Thermoelectric Air-Conditioning System for Remote Applications
    Alomair, Muath
    Alomair, Yazeed
    Mahmud, Shohel
    Abdullah, Hussein A.
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2015, 7 (02)
  • [2] Andersen JR., 1962, Adv Energy Conv, V2, P241
  • [3] Computational and experimental study of a complete heat dissipation system using water as heat carrier placed on a thermoelectric generator
    Aranguren, Patricia
    Astrain, David
    Gurutze Perez, Miren
    [J]. ENERGY, 2014, 74 : 346 - 358
  • [4] Increase of COP in the thermoelectric refrigeration by the optimization of heat dissipation
    Astrain, D
    Vián, JG
    Domínguez, M
    [J]. APPLIED THERMAL ENGINEERING, 2003, 23 (17) : 2183 - 2200
  • [5] Chang YW., 2007, WORLD ACAD SCI ENG T, V33, P128
  • [6] An experimental and numerical study of a thermoelectric air-cooling and air-heating system
    Cosnier, Matthieu
    Fraisse, Gilles
    Luo, Lingai
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (06): : 1051 - 1062
  • [7] Optimization of cross flow heat exchangers for thermoelectric waste heat recovery
    Crane, DT
    Jackson, GS
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (9-10) : 1565 - 1582
  • [8] Dai B., 2017, THERMODYNAMIC PERFOR, V2017
  • [9] Theoretical and experimental estimation of limiting input heat flux for thermoelectric power generators with passive cooling
    Date, Ashwin
    Date, Abhijit
    Dixon, Chris
    Singh, Randeep
    Akbarzadeh, Aliakbar
    [J]. SOLAR ENERGY, 2015, 111 : 201 - 217
  • [10] Experiments on New Arrangements of Convex and Concave Corrugated Tubes through a Double-pipe Heat Exchanger
    Dizaji, Hamed Sadighi
    Jafarmadar, Samad
    [J]. EXPERIMENTAL HEAT TRANSFER, 2016, 29 (05) : 577 - 592