Development of a questionnaire to assess the relative subjective benefits of presbyopia correction

被引:66
作者
Buckhurst, Phillip J. [1 ,4 ]
Wolffsohn, James S. [1 ]
Gupta, Navneet [1 ]
Naroo, Shehzad A. [1 ]
Davies, Leon N. [1 ]
Shah, Sunil [2 ,3 ]
机构
[1] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
[2] Ophthalm Res Grp, Birmingham, W Midlands, England
[3] Midland Eye Inst, Birmingham, W Midlands, England
[4] Univ Plymouth, Peninsula Allied Hlth Ctr, Plymouth PL4 8AA, Devon, England
关键词
QUALITY-OF-LIFE; ACCOMMODATING INTRAOCULAR-LENS; PSYCHOMETRIC PROPERTIES; CATARACT-SURGERY; VISION; IMPLANTATION;
D O I
10.1016/j.jcrs.2011.07.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To develop a standardized questionnaire of near visual function and satisfaction to complement visual function evaluations of presbyopic corrections. SETTING: Eye Clinic, School of Life and Health Sciences, Aston University, Midland Eye Institute and Solihull Hospital, Birmingham, United Kingdom. DESIGN: Questionnaire development. METHODS: A preliminary 26-item questionnaire of previously used near visual function items was completed by patients with monofocal intraocular lenses (IOLs), multifocal IOLs, accommodating IOLs, multifocal contact lenses, or varifocal spectacles. Rasch analysis was used for item reduction, after which internal and test-retest reliabilities were determined. Construct validity was determined by correlating the resulting Near Activity Visual Questionnaire (NAVQ) scores with near visual acuity and critical print size (CPS), which was measured using the Minnesota Low Vision Reading Test chart. Discrimination ability was assessed through receiver-operating characteristic (ROC) curve analysis. RESULTS: One hundred fifty patients completed the questionnaire. Item reduction resulted in a 10-item NAVQ with excellent separation (2.92), internal consistency (Cronbach alpha = 0.95), and test-retest reliability (intraclass correlation coefficient = 0.72). Correlations of questionnaire scores with near visual acuity (r = 0.32) and CPS (r = 0.27) provided evidence of validity, and discrimination ability was excellent (area under ROC curve = 0.91). CONCLUSION: Results show the NAVQ is a reliable, valid instrument that can be incorporated into the evaluation of presbyopic corrections.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 29 条
[1]   Presbyopia correction with an anterior chamber phakic multifocal intraocular lens [J].
Alió, JL ;
Mulet, ME .
OPHTHALMOLOGY, 2005, 112 (08) :1368-1374
[2]   Near vision restoration with refractive lens exchange and pseudoaccommodating and multifocal refractive and diffractive intraocular lenses -: Comparative clinical study [J].
Alió, JL ;
Tavolato, M ;
De la Hoz, F ;
Claramonte, P ;
Rodríguez-Prats, JL ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (12) :2494-2503
[3]  
[Anonymous], 1961, P 4 BERK S MATH STAT
[4]   VISION CHANGE AND QUALITY-OF-LIFE IN THE ELDERLY - RESPONSE TO CATARACT-SURGERY AND TREATMENT OF OTHER CHRONIC OCULAR CONDITIONS [J].
BRENNER, MH ;
CURBOW, B ;
JAVITT, JC ;
LEGRO, MW ;
SOMMER, A .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (05) :680-685
[5]   ReSTOR intraocular lens implantation in cataract surgery: Quality of vision [J].
Chiam, Patrick J. T. ;
Chan, Jin H. ;
Aggarwal, Rajesh K. ;
Kasaby, Sam .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09) :1459-1463
[7]  
Cohen J., 1988, Statistical power analysis for the behavioral sciences, VSecond
[8]   Clinical evaluation of the Crystalens AT-45 accommodating intraocular lens - Results of the US Food and Drug Administration clinical trial [J].
Cumming, JS ;
Colvard, DM ;
Dell, SJ ;
Doane, J ;
Fine, IH ;
Hoffman, RS ;
Packer, M ;
Slade, SG .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :812-825
[9]  
Gupta Navneet, 2009, Optom Vis Sci, V86, pE98, DOI 10.1097/OPX.0b013e318194eb18
[10]  
Gupta Navneet, 2007, Cont Lens Anterior Eye, V30, P134, DOI 10.1016/j.clae.2007.01.004