A Novel Type of Absorber Presenting a Constant Detection Efficiency for up to 25 keV X-Ray Photons

被引:6
作者
Rodrigues, M. [1 ]
Loidl, M. [1 ]
Le-Bret, C. [1 ]
机构
[1] CEA, LIST, Lab Natl Henry Becquerel, F-91191 Gif Sur Yvette, France
关键词
X-ray spectrometry; Metallic magnetic calorimeters; Cryogenic detectors; METALLIC MAGNETIC CALORIMETERS; SPECTROMETRY;
D O I
10.1007/s10909-012-0537-3
中图分类号
O59 [应用物理学];
学科分类号
摘要
A novel type of absorber, dedicated to cryogenic detectors, was conceived to reach a high and constant intrinsic detection efficiency (> 98%) for up to 25 keV X-ray photons. The absorber consists of two layers having a different atomic number Z. The role of the first layer (large Z) is to make negligible the transmission through the absorber; while the second layer (medium Z) has to reabsorb the escape photons from the first layer. A metallic magnetic calorimeter was realized with an Au-Ag absorber. The required thicknesses of both layers were determined using Monte Carlo simulation of the efficiency. To show the advantages of such a detector, its efficiency and its energy resolution are compared to the efficiency and energy resolution of a gold absorber using a Am-241 source.
引用
收藏
页码:510 / 515
页数:6
相关论文
共 8 条
[1]   Performance of TES X-ray microcalorimeters with a novel absorber design [J].
Bandler, S. R. ;
Brekosky, R. P. ;
Brown, A. -D. ;
Chervenak, J. A. ;
Figueroa-Feliciano, E. ;
Finkbeiner, F. M. ;
Iyomoto, N. ;
Kelley, R. L. ;
Kilbourne, C. A. ;
Porter, F. S. ;
Sadleir, J. ;
Smith, S. J. .
JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (1-2) :400-405
[2]   Microstructured magnetic calorimeter with meander-shaped pickup coil [J].
Burck, A. ;
Kempf, S. ;
Schafer, S. ;
Rotzinger, H. ;
Rodrigues, M. ;
Wolf, T. ;
Gastaldo, L. ;
Fleischmann, A. ;
Enss, C. .
JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (1-2) :337-344
[3]   ATOMIC-LEVEL WIDTHS FOR X-RAY SPECTROMETRY [J].
CAMPBELL, JL ;
PAPP, T .
X-RAY SPECTROMETRY, 1995, 24 (06) :307-319
[4]  
Fleischmann A, 2005, TOP APPL PHYS, V99, P151
[5]   High-energy resolution alpha spectrometry using cryogenic detectors [J].
Leblanc, E. ;
Coron, N. ;
Leblanc, J. ;
de Marcillac, P. ;
Bouchard, J. ;
Plagnard, J. .
APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) :1281-1286
[6]   Measurement of 241Am L X-ray emission probabilities [J].
Lepy, M. C. ;
Plagnard, J. ;
Ferreux, L. .
APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) :715-721
[7]   Metallic magnetic calorimeters for γ-ray spectrometry [J].
Rodrigues, M. ;
Pabinger, A. ;
Lausberg, S. ;
Loidl, M. ;
Censier, B. ;
Bouchard, J. ;
Fleischmann, L. ;
Fleischmann, A. ;
Enss, C. .
LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 :583-+
[8]  
Rotzinger H., 2006, THESIS U HEIDELBERG