On blends R32/R134a and R32/R125: Thermodynamic and heat transfer aspects

被引:3
|
作者
Stegou-Sagia, A [1 ]
机构
[1] Natl Tech Univ Athens, Dept Mech Engn, Thermal Sect, GR-15780 Athens, Greece
关键词
ozone-friendly mixtures; thermophysical properties; condensation heat transfer;
D O I
10.1002/er.722
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper the author develops an algorithm on the basis of heat and thermodynamics theory, to predict data for film condensation on horizontal integral-fin tubes for R32/R134a and R32/R125 mixtures in 25/75, 50/50 per cent compositions by mass correspondingly. Emphasis is focused on the presentation of thermophysical properties of the blends involved in the process considered i.e. liquid density, viscosity, surface tension, thermal conductivity and latent heat of vaporization. The main point of this work is to define with computational techniques the blend with the most favourable composition, as an environmentally acceptable solution For R22 replacement in some shell-side condensers. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:793 / 802
页数:10
相关论文
共 50 条
  • [1] Viscosity of R134a, R32, And R125 at Saturation
    C. M. B. P. Oliveira
    W. A. Wakeham
    International Journal of Thermophysics, 1999, 20 : 365 - 373
  • [2] Viscosity of R134a, R32, and R125 at saturation
    Oliveira, CMBP
    Wakeham, WA
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1999, 20 (02) : 365 - 373
  • [3] Transport properties of refrigerants R32, R125, R134a, and R125+R32 mixtures in and beyond the critical region
    Kiselev, S.B.
    Perkins, R.A.
    Huber, M.L.
    International Journal of Refrigeration, 1999, 22 (06): : 509 - 520
  • [4] Transport properties of refrigerants R32, R125, R134a, and R125+R32 mixtures in and beyond the critical region
    Kiselev, SB
    Perkins, RA
    Huber, ML
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (06): : 509 - 520
  • [5] THE VISCOSITY OF R32 AND R125 AT SATURATION
    OLIVEIRA, CMBP
    WAKEHAM, WA
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1993, 14 (06) : 1131 - 1143
  • [6] Performance Comparison among Heat Pump Water Heaters Working with R32, R134a and the Mixture of R32/R134a
    Ding, Defeng
    Liu, Shijie
    Zheng, Chaoyu
    Yu, Wensheng
    Chen, Wu
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 1295 - 1298
  • [7] Investigation of Heat Pump Efficiency on Zeotropic Refrigerants R32/R134a and R32/R152a
    Mezentseva, N. N.
    Mezentsev, I. V.
    JOURNAL OF ENGINEERING THERMOPHYSICS, 2018, 27 (04) : 554 - 559
  • [8] Vapour-liquid equilibrium of ternary mixtures of the refrigerants R32, R125 and R134a
    Nagel, M
    Bier, K
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (08): : 534 - 543
  • [9] Investigation of Heat Pump Efficiency on Zeotropic Refrigerants R32/R134a and R32/R152a
    N. N. Mezentseva
    I. V. Mezentsev
    Journal of Engineering Thermophysics, 2018, 27 : 554 - 559
  • [10] Pool boiling heat transfer of refrigerant mixtures R32/R125
    Shen, JY
    Spindler, K
    Hahne, E
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1999, 26 (08) : 1091 - 1102