Minimally-invasive internal fixation of extra-articular distal femur fractures using a locking plate: Tricks of the trade

被引:25
作者
Ehlinger, M. [1 ]
Adam, P. [1 ]
Abane, L. [1 ]
Arlettaz, Y. [2 ]
Bonnomet, F. [1 ]
机构
[1] Strasbourg Univ Hosp, Hautepierre Med Ctr, Orthopaed Surg & Traumatol Dept, F-67098 Strasbourg 1, France
[2] Valais Hosp, Orthopaed Surg & Musculo Skeletal Traumatol Dept, CH-1951 Sion, Switzerland
关键词
Femur fractures; Locking plate; Mini-invasive surgery; Traumatology; SCREW; BONE; OSTEOSYNTHESIS; COMPRESSION; STABILITY;
D O I
10.1016/j.otsr.2010.11.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fractures of the distal femur are rare and occur in two distinct population categories: young patients after high energy traumas and elderly patients who fall from their full height, and often carry severe co-morbidities making especially difficult to manage theses complex injuries. In elderly patients the potential complications are numerous including infection, non-union and frequent function deterioration. We present a technique of minimally invasive internal fixation of the distal extra-articular femur using a locking plate and present the tricks of the trade to obtain successful reduction and achieve union. The hardware used includes plate fixation with a large fragment locking screw. This minimally invasive surgery combines stability of the internal fixation device with the principles of closed surgery, allowing early mobilization and immediate weight bearing to warrant good functional recovery. (C) 2011 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:201 / 205
页数:5
相关论文
共 17 条
[1]   Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? [J].
Ahmad, M. ;
Nanda, R. ;
Bajwa, A. S. ;
Candal-Couto, J. ;
Green, S. ;
Hui, A. C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (03) :358-364
[2]   The results of open reduction and internal fixation of distal femur fractures using a biologic (Indirect) reduction technique [J].
Bolhofner, BR ;
Carmen, B ;
Clifford, P .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (06) :372-377
[3]   A Nonlocking End Screw Can Decrease Fracture Risk Caused by Locked Plating in the Osteoporotic Diaphysis [J].
Bottlang, Michael ;
Doornink, Josef ;
Byrd, Gregory D. ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (03) :620-627
[4]   Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: A cadaveric model [J].
Dougherty, Paul J. ;
Kim, Do-Gyoon ;
Meisterling, Steve ;
Wybo, Christopher ;
Yeni, Yener .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (06) :399-403
[5]   Treatment of femoral fracture on previous implants with minimally-invasive surgery and total weight-bearing: Benefit of locking plate. Preliminary report [J].
Ehlinger, M. ;
Cognet, J. -M. ;
Simon, P. .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2008, 94 (01) :26-36
[6]  
Ehlinger M, 2010, ORTHOP TRAUMATOL-SUR, V96, P43, DOI [10.1016/j.rcot.2009.11.002, 10.1016/j.otsr.2009.09.012]
[7]   Minimally invasive plate osteosynthesis: Does percutaneous plating disrupt femoral blood supply less than the traditional technique? [J].
Farouk, O ;
Krettek, C ;
Miclau, T ;
Schandelmaier, P ;
Guy, P ;
Tscherne, H .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (06) :401-406
[8]  
Gwathmey FW, 2010, J AM ACAD ORTHOP SUR, V18, P597
[9]   Treatment of distal femur fractures using the Less Invasive Stabilization System - Surgical experience and early clinical results in 103 fractures [J].
Kregor, PJ ;
Stannard, JA ;
Zlowodzki, M ;
Cole, PA .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :509-520
[10]  
Lungershausen W, 1997, ZBL CHIR, V122, P954