Experimental Investigation and Numerical Modeling of a Joule-Heated Ceramic Melter for Vitrification of Radioactive Waste

被引:9
作者
Suneel, G. [1 ]
Sai, P. M. Satya [2 ]
Kaushik, Chetan P. [3 ]
Gayen, J. K. [4 ]
Ravi, K. V. [5 ]
Roy, Amitava [5 ]
机构
[1] Homi Bhabha Natl Inst, Bombay 400094, Maharashtra, India
[2] Natl Inst Technol Warangal, Dept Chem Engn, Warangal 506004, Andhra Pradesh, India
[3] Bhabha Atom Res Ctr, Waste Management Div, Bombay 400085, Maharashtra, India
[4] Bhabha Atom Res Ctr Facil, Nucl Recycle Board, Waste Immobilizat Plant, Kalpakkam 603102, Tamil Nadu, India
[5] Bhabha Atom Res Ctr, Nucl Recycle Board, Bombay 400085, Maharashtra, India
关键词
Joule miter; Cold cap; Glass; Vitrification; Effective thermal conductivity of glass; GLASS; FLOW;
D O I
10.1061/(ASCE)HZ.2153-5515.0000429
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radioactive liquid waste generated in the closed nuclear fuel cycle is immobilized by fixing the radionuclides in glass by a process known as vitrification. Vitrification is carried out in a joule-heated ceramic melter (JHCM) by passing alternate current in glass melt using electrodes. Silicon carbide resistance heaters are employed to bring the temperature of the glass to the conducting zone. Experiments were carried out on an industrial scale JHCM. Processing capacities were determined for glass melt having a composition of SiO2 (48%), B2O3 (26.3%), Na2O (11.7%), TiO2 (9.5%), and Fe2O3 (4.5%) for simulated waste with different salt concentrations. The product formed from these trials is qualified for long-term durability based on the study. The energy distribution in an industrial scale JHCM for different salt concentrations, namely, 28 and 56 g/L of simulated waste is calculated based on the experiments conducted. This study also focuses on mathematical modeling of an all-electric glass furnace used for conditioning of hazardous radioactive waste. In this work, a numerical model of the glass furnace was developed and heat flow patterns in a JHCM were studied using finite element analysis. The numerical model is then used to predict the temperature profiles for different stages of the JHCM operation. The temperature profiles predicted by the model are validated using experimental results. The developed model is used for size reduction of the JHCM by decreasing the plenum heating section, thereby facilitating easier decommissioning. A novel method for estimating the effective thermal conductivity of the glass melt based on the experiments and simulations is discussed. (C) 2018 American Society of civil Engineers.
引用
收藏
页数:14
相关论文
共 24 条
[11]   Conversion of nuclear waste into nuclear waste glass: Experimental investigation and mathematical modeling [J].
Hrma, Pavel .
2ND INTERNATIONAL SUMMER SCHOOL ON NUCLEAR GLASS WASTEFORM: STRUCTURE, PROPERTIES AND LONG-TERM BEHAVIOR (SUMGLASS 2013), 2014, 7 :117-123
[12]  
IAEA (International Atomic Energy Agency), 1988, IAEA TECHN SER REP, V291
[13]  
Jakob M., 1942, HEAT TRANSFER
[14]  
Kaushik C. P., 2008, BARC2004E018
[15]  
Matsuno S., 2008, Journal of Power and Energy Systems, V2, P447, DOI [10.1299/jpes.2.447, DOI 10.1299/JPES.2.447]
[16]  
Matyas J., 2002, MELT RATE IMPROVEMEN
[17]  
Pepper D. W., 1992, BASIC CONCEPTS APPL
[18]   One-Dimensional Cold Cap Model for Melters with Bubblers [J].
Pokorny, Richard ;
Hilliard, Zachary J. ;
Dixon, Derek R. ;
Schweiger, Michael J. ;
Guillen, Donna P. ;
Kruger, Albert A. ;
Hrma, Pavel .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2015, 98 (10) :3112-3118
[19]   Mathematical modeling of cold cap [J].
Pokorny, Richard ;
Hrma, Pavel .
JOURNAL OF NUCLEAR MATERIALS, 2012, 429 (1-3) :245-256
[20]   Radioactive waste management practices in India [J].
Raj, K ;
Prasad, KK ;
Bansal, NK .
NUCLEAR ENGINEERING AND DESIGN, 2006, 236 (7-8) :914-930