Time- and Frequency-Domain Fault Detection in a VSC-Interfaced Experimental DC Test System

被引:75
作者
Yeap, Yew Ming [1 ]
Geddada, Nagesh [1 ]
Satpathi, Kuntal [1 ]
Ukil, Abhisek [2 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[2] Univ Auckland, Dept Elect & Comp Engn, Auckland 1010, New Zealand
关键词
DC fault; dc-link capacitor; fault detection; short-time Fourier transform (STFT); voltage-source converter (VSC); wavelet transform (WT); PROTECTION SCHEME; TRANSIENT ANALYSIS; LOCATION METHOD; WAVELET;
D O I
10.1109/TII.2018.2796068
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The rapid discharge of a dc-link capacitor of the voltage-source converter (VSC)-based dc system is the primary indication of the fault condition. Apart from the time-domain analysis, frequency-domain analysis of the fault current could also be utilized for dc fault detection, as the rapidly rising fault current is expected to have high-frequency components. This paper proposes two fault detection methods and compares their performances with the wavelet transform. The first method is the time-domain analysis of the dc-link capacitor discharge and is termed as the capacitive discharge technique. The relationship between the dc line current and the behavior of the dc-link capacitor is measured in terms of a correlation coefficient, whose value can be used to establish a fault basis. The second method is the frequency-domain-based short-time Fourier transform, which is used for quantitative analysis of high-frequency components in the fault current. These methods are extensively analyzed and compared using a scaled-down VSC-based dc system experimental test setup. Comparison has been done based on fault detection time, sensitivity to fault parameters, influence of sampling frequency, and computation speed. Furthermore, the selectivity of the fault detection methods is studied on the multiterminal dc systems of two different topologies (ring and radial), modeled in PSCAD/EMTDC. The experimental and simulation results substantiate the applicability of all the methods to the dc system. Brief comparative analysis with the di/dt method is also presented to highlight the advantages of the proposed methods.
引用
收藏
页码:4353 / 4364
页数:12
相关论文
共 28 条
[1]  
Abdelgayed T., 2017, IEEE T SMART GRID
[2]  
[Anonymous], 2009, IEDM DEC, DOI DOI 10.1109/IEDM.2009.5424403
[3]   Fault location on multi-terminal DC systems using synchronized current measurements [J].
Azizi, Sadegh ;
Afsharnia, Saeed ;
Sanaye-Pasand, Majid .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 63 :779-786
[4]   Multiterminal HVDC Networks-What is the Preferred Topology? [J].
Bucher, Matthias K. ;
Wiget, Roger ;
Andersson, Goeran ;
Franck, Christian M. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (01) :406-413
[5]   Wavelet-based protection strategy for DC faults in multi-terminal VSC HVDC systems [J].
De Kerf, K. ;
Srivastava, K. ;
Reza, M. ;
Bekaert, D. ;
Cole, S. ;
Van Hertem, D. ;
Belmans, R. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (04) :496-503
[6]  
dos Santos A., 2017, IEEE T IND INFORM
[7]   Event-Based Protection Scheme for a Multiterminal Hybrid DC Power System [J].
Farhadi, Mustafa ;
Mohammed, Osama A. .
IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (04) :1658-1669
[8]   A Novel Fault-Location Method for HVDC Transmission Lines Based on Similarity Measure of Voltage Signals [J].
Farshad, Mohammad ;
Sadeh, Javad .
IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (04) :2483-2490
[9]   A Novel Fault Location Method and Algorithm for DC Distribution Protection [J].
Feng, Xianyong ;
Qi, Li ;
Pan, Jiuping .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (03) :1834-1840
[10]   Novel pilot protection principle for high-voltage direct current transmission lines based on fault component current characteristics [J].
Gao, Shuping ;
Song, Guobing ;
Ma, Zhibin ;
Jin, Xingfu .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (05) :468-474