Manual, semiautomated, and fully automated measurement of the aortic annulus for planning of transcatheter aortic valve replacement (TAVR/TAVI): Analysis of interchangeability

被引:31
作者
Lou, Junyang [1 ]
Obuchowski, Nancy A. [2 ,3 ]
Krishnaswamy, Amar [1 ]
Popovic, Zoran [1 ,2 ]
Flamm, Scott D. [1 ,2 ]
Kapadia, Samir R. [1 ]
Svensson, Lars G. [1 ]
Bolen, Michael A. [1 ,2 ]
Desai, Milind Y. [1 ,2 ]
Halliburton, Sandra S. [1 ,2 ]
Tuzcu, E. Murat [1 ]
Schoenhagen, Paul [1 ,2 ]
机构
[1] Cleveland Clin, Inst Heart & Vasc, Cleveland, OH 44106 USA
[2] Cleveland Clin, Imaging Inst, Cleveland, OH 44106 USA
[3] Cleveland Clin, Quantitat Hlth Sci, Cleveland, OH 44106 USA
关键词
TAVR; TAVI; Aortic stenosis; Computed tomography; Aortic annulus; Semi-automated analysis; MULTIDETECTOR COMPUTED-TOMOGRAPHY; IMPLANTATION; ROOT; TAVR; MULTICENTER; SELECTION; STENOSIS; TOOL;
D O I
10.1016/j.jcct.2014.11.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Preprocedural 3-dimensional CT imaging of the aortic annular plane plays a critical role for transcatheter aortic valve replacement (TAVR) planning; however, manual reconstructions are complex. Automated analysis software may improve reproducibility and agreement between readers but is incompletely validated. Methods: In 110 TAVR patients (mean age, 81 years; 37% female) undergoing preprocedural multidetector CT, automated reconstruction of the aortic annular plane and planimetry of the annulus was performed with a prototype of now commercially available software (syngo.CT Cardiac Function-Valve Pilot; Siemens Healthcare, Erlangen, Germany). Fully automated, semiautomated, and manual annulus measurements were compared. Intrareader and inter-reader agreement, intermodality agreement, and interchangeability were analyzed. Finally, the impact of these measurements on recommended valve size was evaluated. Results: Semiautomated analysis required major correction in 5 patients (4.5%). In the remaining 95.5%, only minor correction was performed. Mean manual annulus area was significantly smaller than fully automated results (P <.001 for both readers) but similar to semiautomated measurements (5.0 vs 5.4 vs 4.9 cm(2), respectively). The frequency of concordant recommendations for valve size increased if manual analysis was replaced with the semiautomated method (60% agreement was improved to 82.4%; 95% confidence interval for the difference [69.1%-83.4%]). Conclusions: Semiautomated aortic annulus analysis, with minor correction by the user, provides reliable results in the context of TAVR annulus evaluation. (C) 2015 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 18 条
[1]   SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) [J].
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Schoenhagen, Paul ;
Min, James K. ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) :366-380
[2]   Aortic root morphology in patients undergoing percutaneous aortic valve replacement: Evidence of aortic root remodeling [J].
Akhtar, Mateen ;
Tuzcu, E. Murat ;
Kapadia, Samir R. ;
Svensson, Lars G. ;
Greenberg, Roy K. ;
Roselli, Eric E. ;
Halliburton, Sandra ;
Kurra, Vikram ;
Schoenhagen, Paul ;
Sola, Srikanth .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (04) :950-956
[3]   Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement [J].
Barbanti, Marco ;
Yang, Tae-Hyun ;
Cabau, Josep Rodes ;
Tamburino, Corrado ;
Wood, David A. ;
Jilaihawi, Hasan ;
Blanke, Phillip ;
Makkar, Raj R. ;
Latib, Azeem ;
Colombo, Antonio ;
Tarantini, Giuseppe ;
Raju, Rekha ;
Binder, Ronald K. ;
Nguyen, Giang ;
Freeman, Melanie ;
Ribeiro, Henrique B. ;
Kapadia, Samir ;
Min, James ;
Feuchtner, Gudrun ;
Gurtvich, Ronen ;
Alqoofi, Faisal ;
Pelletier, Marc ;
Ussia, Gian Paolo ;
Napodano, Massimo ;
de Brito, Fabio Sandoli ;
Kodali, Susheel ;
Norgaard, Bjarne L. ;
Hansson, Nicolaj C. ;
Pache, Gregor ;
Canovas, Sergio J. ;
Zhang, Hongbin ;
Leon, Martin B. ;
Webb, John G. ;
Leipsic, Jonathon .
CIRCULATION, 2013, 128 (03) :244-253
[4]   The Impact of Integration of a Multidetector Computed Tomography Annulus Area Sizing Algorithm on Outcomes of Transcatheter Aortic Valve Replacement A Prospective, Multicenter, Controlled Trial [J].
Binder, Ronald K. ;
Webb, John G. ;
Willson, Alexander B. ;
Urena, Marina ;
Hansson, Nicolaj C. ;
Norgaard, Bjarne L. ;
Pibarot, Philippe ;
Barbanti, Marco ;
Larose, Eric ;
Freeman, Melanie ;
Dumont, Eric ;
Thompson, Chris ;
Wheeler, Miriam ;
Moss, Robert R. ;
Yang, Tae-hyun ;
Pasian, Sergio ;
Hague, Cameron J. ;
Giang Nguyen ;
Raju, Rekha ;
Toggweiler, Stefan ;
Min, James K. ;
Wood, David A. ;
Rodes-Cabau, Josep ;
Leipsic, Jonathon .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (05) :431-438
[5]   Semiautomated Quantification of Aortic Annulus Dimensions on Cardiac CT for TAVR [J].
Blanke, Philipp ;
Spira, Eva Maria ;
Ionasec, Razvan ;
Meinel, Felix G. ;
Ebersberger, Ullrich ;
Scheuering, Michael ;
Canstein, Christian ;
Flohr, Thomas G. ;
Langer, Mathias ;
Schoepf, U. Joseph .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (03) :320-322
[6]   Prospective ECG-triggered, axial 4-D imaging of the aortic root, valvular, and left ventricular structures: A lower radiation dose option for preprocedural TAVR imaging [J].
Bolen, Michael A. ;
Popovic, Zoran B. ;
Dahiya, Arun ;
Kapadia, Samir R. ;
Tuzcu, E. Murat ;
Flamm, Scott D. ;
Halliburton, Sandra S. ;
Schoenhagen, Paul .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) :393-398
[7]   Characterization and outcome of patients with severe symptomatic aortic stenosis referred for percutaneous aortic valve replacement [J].
Kapadia, Samir R. ;
Goel, Sachin S. ;
Svensson, Lars ;
Roselli, Eric ;
Savage, Robert M. ;
Wallace, Lee ;
Sola, Srikanth ;
Schoenhagen, Paul ;
Shishehbor, Mehdi H. ;
Christofferson, Ryan ;
Halley, Carmel ;
Rodriguez, L. Leonardo ;
Stewart, William ;
Kalahasti, Vidyasagar ;
Tuzcu, E. Murat .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (06) :1430-1435
[8]   Standardized Imaging for Aortic Annular Sizing Implications for Transcatheter Valve Selection [J].
Kasel, Albert M. ;
Cassese, Salvatore ;
Bleiziffer, Sabine ;
Amaki, Makoto ;
Hahn, Rebecca T. ;
Kastrati, Adnan ;
Sengupta, Partho P. .
JACC-CARDIOVASCULAR IMAGING, 2013, 6 (02) :249-262
[9]   Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium [J].
Leon, Martin B. ;
Piazza, Nicolo ;
Nikolsky, Eugenia ;
Blackstone, Eugene H. ;
Cutlip, Donald E. ;
Kappetein, Arie Pieter ;
Krucoff, Mitchell W. ;
Mack, Michael ;
Mehran, Roxana ;
Miller, Craig ;
Morel, Marie-Angele ;
Petersen, John ;
Popma, Jeffrey J. ;
Takkenberg, Johanna J. M. ;
Vahanian, Alec ;
van Es, Gerrit-Anne ;
Vranckx, Pascal ;
Webb, John G. ;
Windecker, Stephan ;
Serruys, Patrick W. .
EUROPEAN HEART JOURNAL, 2011, 32 (02) :205-U144
[10]   Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery. [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael ;
Miller, D. Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Brown, David L. ;
Block, Peter C. ;
Guyton, Robert A. ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Douglas, Pamela S. ;
Petersen, John L. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (17) :1597-1607