On the use of multi-dimensional scaling and electromagnetic tracking in high dose rate brachytherapy

被引:8
作者
Goetz, Th I. [1 ,2 ]
Ermer, M. [1 ]
Salas-Gonzalez, D. [4 ]
Kellermeier, M. [2 ]
Strnad, V. [2 ]
Bert, Ch [2 ]
Hensel, B. [5 ]
Tome, A. M. [3 ]
Lang, E. W. [1 ]
机构
[1] Univ Regensburg, CIML, Biophys, D-93040 Regensburg, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg, Dept Radiat Oncol, Univ KLinikum Erlangen, D-91054 Erlangen, Germany
[3] Univ Aveiro, DETI, IEETA, P-3810193 Aveiro, Portugal
[4] Univ Granada, DTSTC, E-18071 Granada, Spain
[5] Univ Erlangen Nurnberg, Ctr Med Phys & Engn, D-91052 Erlangen, Germany
关键词
multi-dimensional scaling; electromagnetic tracking; brachytherapy; Levy distributions; hartigan-dip-test; BREAST IRRADIATION; BAYESIAN-INFERENCE; QUALITY-ASSURANCE; SURGERY;
D O I
10.1088/1361-6560/aa8944
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High dose rate brachytherapy affords a frequent reassurance of the precise dwell positions of the radiation source. The current investigation proposes a multi-dimensional scaling transformation of both data sets to estimate dwell positions without any external reference. Furthermore, the related distributions of dwell positions are characterized by uni-or bi-modal heavy-tailed distributions. The latter are well represented by alpha-stable distributions. The newly proposed data analysis provides dwell position deviations with high accuracy, and, furthermore, offers a convenient visualization of the actual shapes of the catheters which guide the radiation source during the treatment.
引用
收藏
页码:7959 / 7980
页数:22
相关论文
共 41 条
  • [1] Abdi H., 2007, ENCY RES METHODS SOC, P598, DOI DOI 10.4135/9781412952644
  • [2] Balachandran R, 2009, SPIE MED IMAGING, V7261
  • [3] Beeksma B, 2014, THESIS
  • [4] Electromagnetic tracking for treatment verification in interstitial brachytherapy
    Bert, Christoph
    Kellermeier, Markus
    Tanderup, Kari
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (05) : 448 - 453
  • [5] Electromagnetic tracking for catheter reconstruction in ultrasound-guided high-dose-rate brachytherapy of the prostate
    Bharat, Shyam
    Kung, Cynthia
    Dehghan, Ehsan
    Ravi, Ananth
    Venugopal, Niranjan
    Bonillas, Antonio
    Stanton, Doug
    Kruecker, Jochen
    [J]. BRACHYTHERAPY, 2014, 13 (06) : 640 - 650
  • [6] Borg I., 2005, MODERN MULTIDIMENSIO
  • [7] BAYESIAN-INFERENCE FOR STABLE-DISTRIBUTIONS
    BUCKLE, DJ
    [J]. JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1995, 90 (430) : 605 - 613
  • [8] Coles S., 2001, An introduction to statistical modeling of extreme values, DOI [10.1007/978-1-4471-3675-0, DOI 10.1007/978-1-4471-3675-0]
  • [9] Cox T F, 1994, SPRINGER SERIES STAT
  • [10] A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization
    Damato, Antonio L.
    Viswanathan, Akila N.
    Don, Sarah M.
    Hansen, Jorgen L.
    Cormack, Robert A.
    [J]. MEDICAL PHYSICS, 2014, 41 (10)