THE INFLUENCE OF ALTERNATIVE CHARACTERISTICS OF THE VICINITY OF THE VENTILATION DISTRICT ON AIR QUANTITY

被引:0
|
作者
Pach, Grzegorz [1 ]
机构
[1] Silesian Tech Univ, Fac Min Safety Engn & Ind Automat, 2 Akad Str, PL-44100 Gliwice, Poland
关键词
mine ventilation network; ventilation district; alternative characteristics; ventilation hazards; THERMAL HAZARD; MINE; METHANE; FLOW; STABILITY;
D O I
10.24425/ams.2020.132705
中图分类号
TD [矿业工程];
学科分类号
0819 ;
摘要
Subnetwork with two nodes shared with entire ventilation network can be separated as its part. For the network under common ventilation conditions, one of these nodes will become the subnetwork starting node, while the other will be the subnetwork end node. According to the graphs theory, such a piece of the network can be considered as a subgraph of the graph representing the entire ventilation network. A special feature of that subgraph is lack of predecessors of the subnetwork starting node and lack of successors of the subnetwork end node. Ventilation district of a mine may be ollen treated as a subnetwork. Vicinity is a part of the network which is not separated as subnetwork. In the case of a ventilation district its vicinity forces air flow through the district. The alternative characteristic curve of the vicinity can therefore be compared to the characteristics curve of a fictional fan that forces the airflow in the district. The alternative characteristics (later in the text: the characteristics) of the vicinity of the ventilation district in an underground mine strongly influence air quantity and therefore play a crucial role in the reduction of methane, fire and thermal hazards. The role of these characteristics and proper selection of their approximating function were presented in the article. The reduction of resistance of an intake stopping (having influence on entire resistance or a ventilation district) produces increased airflow in the district. This changes of airflow in the district caused by a variation in internal resistance (e.g. by opening an internal regulation stopping) depends on the characteristic of the vicinity of the district. Proper selection of its approximating function is also important for this matter. The methods of determination of the alternative characteristic curve of the district vicinity are presented. From these procedures it 'was possible to obtain the results of air quantities and differences in isentropic potentials between an inlet and an outlet to/from the ventilation district. Following this, the characteristics were determined by graphic and analytic methods. It was proved that, in contrast to flat vicinity characteristics, steep ones have a smaller influence on the airflow modification in the district (which are caused by a regulation of the district resistance). The characteristic curve of the vicinity determines the ability to regulate air quantity and velocity in the district.
引用
收藏
页码:47 / 58
页数:12
相关论文
共 50 条
  • [31] Cold air and exercise challenge- Influence of minute ventilation
    Sylvester, Karl P.
    O'Connor, Brian J.
    Farebrother, Helen M.
    Rafferty, Gerrard F.
    Greenough, Anne
    JOURNAL OF ASTHMA, 2007, 44 (02) : 143 - 147
  • [32] Influence of Ambient Air Pollution on Natural Ventilation Potential in Europe
    Belias, Evangelos
    Licina, Dusan
    IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,
  • [33] Influence By Ventilation With Nature Wind On The Air Conditioning Energy Consumption
    Jing Yazhou
    Zhao Guojun
    Li Haishan
    Gao Yan
    ENERGY ENGINEERING AND ENVIRONMENTAL ENGINEERING, PTS 1AND 2, 2013, 316-317 : 1128 - +
  • [34] The influence of natural draught on the air flow in a tunnel with longitudinal ventilation
    Krol, Malgorzata
    Krol, Aleksander
    Koper, Piotr
    Wrona, Pawel
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2019, 85 : 140 - 148
  • [35] INFLUENCE OF MECHANICAL VENTILATION ON MOISTURE CONTENT OF BATHROOM AIR.
    Shair, F.H.
    Wolbrink, D.W.
    Bowen, L.O.
    Neelley, C.E.
    Sampsel, K.E.
    ASHRAE Journal, 1979, 21 (07) : 54 - 60
  • [36] AIR DIFFUSION AND INFLUENCE OF THE BOUNDARY EFFECT IN VENTILATION OF SUGAR BEETROOTS
    SENGE, B
    MANZKE, E
    SCHMIDT, PV
    LEBENSMITTELINDUSTRIE, 1990, 37 (01): : 32 - 37
  • [37] The influence on the power consumption for air-conditioning equipment by the ventilation
    Nishitani, Tsuyoshi
    Ikeda, Kazuki
    Iwasaki, Yuto
    Tanaka, Aoi
    Yukita, Kazuto
    Nanahara, Toshiya
    Goto, Tokimasa
    Mizuno, Katsunori
    Goto, Yasuyuki
    2022 10TH INTERNATIONAL CONFERENCE ON SMART GRID, ICSMARTGRID, 2022, : 160 - 164
  • [38] INFLUENCE OF OXYGEN VENTILATION ON SURVIVAL OF AIR EMBOLI IN THE PULMONARY VASCULATURE
    BUTLER, BD
    LUEHR, S
    KATZ, J
    FASEB JOURNAL, 1988, 2 (06): : A1721 - A1721
  • [39] Influence of Ventilation Status on Combustion Characteristics of Coach Fire
    Chen Jie
    Yi Lang
    2012 INTERNATIONAL CONFERENCE ON PERFORMANCE-BASED FIRE AND FIRE PROTECTION ENGINEERING, 2013, 52 : 42 - 47
  • [40] MORE ON INFLUENCE OF CLIMATE ON TOWN DISTRICT HEATING CHARACTERISTICS
    TARANOV, BP
    THERMAL ENGINEERING, 1969, 16 (07) : 44 - &