Fuel cell systems reliability and availability enhancement by developing a fast and efficient power switch open-circuit fault detection algorithm in interleaved DC/DC boost converter topologies

被引:37
作者
Guilbert, Damien [1 ]
N'Diaye, Abdoul [2 ,4 ]
Gaillard, Arnaud [3 ,4 ]
Djerdir, Abdesslem [2 ,4 ]
机构
[1] Univ Grenoble Alpes, G2Elab, 21 Rue Martyrs, F-38000 Grenoble, France
[2] Univ Bourgogne Franche Comte, UTBM, IRTES, EA 7274, F-90010 Belfort, France
[3] Univ Bourgogne Franche Comte, FEMTO ST Inst, Dept Energy, UTBM,UMR CNRS 6174, F-90010 Belfort, France
[4] UTBM, FR CNRS 3539, FCLAB, Fuel Cell Lab, F-90010 Belfort, France
关键词
PEMFC; Interleaved DC/DC converter; Electric vehicle; Power switch fault detection algorithm; Fault-tolerant control; FPGA target; 3-PHASE INDUCTION-MOTORS; DC-DC CONVERTER; DIODE BYPASS CIRCUIT; DIFFERENTIAL PROTECTION; TOLERANT CONTROL; DIAGNOSIS; MULTIPHASE; MULTISTACK; NETWORK; MODES;
D O I
10.1016/j.ijhydene.2016.01.169
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Due to the low and unregulated voltage generated by fuel cells, power electronic conditioning systems such as DC/DC converter are required in Fuel Cell Systems (FCS). These FCS are used in different applications with critical loads such as automotive applications, material handling equipment, and backup power. In these applications, it is crucial to guarantee reliability and availability. In FCS, DC/DC converters are one of the most important failure sources. Since the power switches ranked the most delicate components in DC/DC converters, the development of power switch fault detection algorithm is a mandatory step in order to ensure the availability of the system. The purpose of this paper is to propose a fast and original power switch fault detection algorithm based on Park's vectors combined with a Fault-Tolerant Control (FTC) for a 3-leg Interleaved DC/DC Boost Converter (IBC) used in FCS. The developed power switch fault detection and FTC are implemented on a FPGA target, allowing detecting, identifying and handling quickly the faulty power switch. The obtained results from experimental tests confirm the excellent performances of the proposed power switch fault detection algorithm and the FTC. (C) 2016 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:15505 / 15517
页数:13
相关论文
共 68 条
[1]   On-line fault detection of aluminium electrolytic capacitors, in step-down DC-DC converters, using input current and output voltage ripple [J].
Amaral, A. M. R. ;
Cardoso, A. J. M. .
IET POWER ELECTRONICS, 2012, 5 (03) :315-322
[2]  
[Anonymous], INT J COMADEM
[3]  
[Anonymous], 2015 5 INT YOUTH C E
[4]  
[Anonymous], 2011, THESIS
[5]   Electrical equivalent model of a proton exchange membrane fuel cell with experimental validation [J].
Becherif, M. ;
Hissel, D. ;
Gaagat, S. ;
Wack, M. .
RENEWABLE ENERGY, 2011, 36 (10) :2582-2588
[6]   A review of induction motors signature analysis as a medium for faults detection [J].
Benbouzid, ME .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :984-993
[7]   MPPT controller for an interleaved boost dc-dc converter used in fuel cell electric vehicles [J].
Benyahia, N. ;
Denoun, H. ;
Badji, A. ;
Zaouia, M. ;
Rekioua, T. ;
Benamrouche, N. ;
Rekioua, D. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (27) :15196-15205
[8]   Fault-Tolerant Unfalsified Control for PEM Fuel Cell Systems [J].
Bianchi, Fernando D. ;
Ocampo-Martinez, Carlos ;
Kunusch, Cristian ;
Sanchez-Pena, Ricardo S. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (01) :307-315
[9]  
Blackburn J.Lewis., 1993, Symmetrical Components for Power Systems Engineering
[10]   Fuel cell operation under degraded working modes and study of diode by-pass circuit dedicated to multi-stack association [J].
Candusso, Denis ;
De Bernardinis, Alexandre ;
Pera, Marie-Cecile ;
Harel, Fabien ;
Francois, Xavier ;
Hissel, Daniel ;
Coquery, Gerard ;
Kauffmann, Jean-Marie .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (04) :880-895