Vascular Pressure-Flow Measurement Using CB-PDMS Flexible Strain Sensor

被引:42
作者
Chong, Hao [1 ]
Lou, Jiongcheng [1 ]
Bogie, Kath M. [2 ,3 ]
Zorman, Christian A. [4 ,5 ]
Majerus, Steve J. A. [4 ,5 ]
机构
[1] Case Western Reserve Univ, Dept Elect Engn & Comp Sci, Cleveland, OH 44106 USA
[2] Case Western Reserve Sch Med, Dept Orthopaed, Cleveland, OH 44106 USA
[3] Louis Stokes Cleveland Vet Affairs Med Ctr, Adv Platform Technol Ctr, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Dept Elect Engn & Comp Sci, Cleveland, OH 44106 USA
[5] Louis Stokes Cleveland Vet Affairs Med Ctr, Adv Platform Technol Ctr, Cleveland, OH 44106 USA
关键词
Strain; Blood flow; Arteries; Veins; Monitoring; Capacitive sensors; Carbon Black; Flexible Pulsation Sensor; PDMS; Strain Sensing; Vascular Graft; MECHANICAL-PROPERTIES; VEIN; GRAFTS;
D O I
10.1109/TBCAS.2019.2946519
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Regular monitoring of blood flow and pressure in vascular reconstructions or grafts would provide early warning of graft failure and improve salvage procedures. Based on biocompatible materials, we have developed a new type of thin, flexible pulsation sensor (FPS) which is wrapped around a graft to monitor blood pressure and flow. The FPS uses carbon black (CB) nanoparticles dispersed in polydimethylsiloxane (PDMS) as a piezoresistive sensor layer, which was encapsulated within structural PDMS layers and connected to stainless steel interconnect leads. Because the FPS is more flexible than natural arteries, veins, and synthetic vascular grafts, it can be wrapped around target conduits at the time of surgery and remain implanted for long-term monitoring. In this study, we analyze strain transduction from a blood vessel and characterize the electrical and mechanical response of CB-PDMS from 0-50 strain. An optimum concentration of 14 CB-PDMS was used to fabricate 300-m thick FPS devices with elastic modulus under 500 kPa, strain range of over 50, and gauge factor greater than 5. Sensors were tested in vitro on vascular grafts with flows of 0-1,100 mL/min. In vitro testing showed linear output to pulsatile flows and pressures. Cyclic testing demonstrated robust operation over hundreds of cardiac cycles, with 2.6 mmHg variation in pressure readout. CB-PDMS composite material showed excellent potential in biologic strain sensing applications where a flexible sensor with large maximum strain range is needed.
引用
收藏
页码:1451 / 1461
页数:11
相关论文
共 45 条
[1]   Atherosclerosis, and Newton, Poiseuille, Reynolds and Prandtl [J].
Ahlqvist, J .
MEDICAL HYPOTHESES, 2001, 57 (04) :446-452
[2]  
Allon M., 2014, UPTODATE
[3]   Biomechanics and biocompatibility of the perfect conduit-can we build one? [J].
Byrom, Michael J. ;
Ng, Martin K. C. ;
Bannon, Paul G. .
ANNALS OF CARDIOTHORACIC SURGERY, 2013, 2 (04) :435-443
[4]   FINITE-ELEMENT ANALYSIS OF ARTERIAL ANASTOMOSES WITH VEIN, DACRON AND PTFE GRAFTS [J].
CHANDRAN, KB ;
GAO, D ;
HAN, G ;
BARANIEWSKI, H ;
CORSON, JD .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (04) :413-418
[5]   Intelligent telemetric stent for wireless monitoring of intravascular pressure and its in vivo testing [J].
Chen, Xing ;
Brox, Daniel ;
Assadsangabi, Babak ;
Hsiang, York ;
Takahata, Kenichi .
BIOMEDICAL MICRODEVICES, 2014, 16 (05) :745-759
[6]   Super-hydrophobic, durable and cost-effective carbon black/rubber composites for high performance strain sensors [J].
Chen, Yang ;
Wang, Ling ;
Wu, Zefeng ;
Luo, Junchen ;
Li, Bei ;
Huang, Xuewu ;
Xue, Huaiguo ;
Gao, Jiefeng .
COMPOSITES PART B-ENGINEERING, 2019, 176
[7]   An Inductively Powered Implantable Blood Flow Sensor Microsystem for Vascular Grafts [J].
Cheong, Jia Hao ;
Ng, Simon Sheung Yan ;
Liu, Xin ;
Xue, Rui-Feng ;
Lim, Huey Jen ;
Khannur, Pradeep Basappa ;
Chan, Kok Lim ;
Lee, Andreas Astuti ;
Kang, Kai ;
Lim, Li Shiah ;
He, Cairan ;
Singh, Pushpapraj ;
Park, Woo-Tae ;
Je, Minkyu .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (09) :2466-2475
[8]  
DARIO P, 1983, T AM SOC ART INT ORG, V29, P318
[9]   On the Analysis of Fingertip Photoplethysmogram Signals [J].
Elgendi, Mohamed .
CURRENT CARDIOLOGY REVIEWS, 2012, 8 (01) :14-25
[10]   Reduced elastic mismatch achieved by interposing vein cuff in expanded polytetrafluoroethylene femoral bypass decreases intimal hyperplasia [J].
Fischer, EIC ;
Santana, DB ;
Cassanello, GL ;
Zócalo, Y ;
Crawford, EV ;
Casas, RF ;
Armentano, RL .
ARTIFICIAL ORGANS, 2005, 29 (02) :122-130