The Effect of an Implanted Filter on Valsalva-Compression and Respiratory-Compression of the Inferior Vena Cava

被引:0
|
作者
Kossa, Attila [1 ,2 ,3 ]
McMeeking, Robert M. [2 ,3 ,4 ,5 ]
机构
[1] Budapest Univ Technol & Econ, Fac Mech Engn, Dept Appl Mech, Budapest, Hungary
[2] Univ Calif Santa Barbara, Dept Mat, Santa Barbara, CA 93106 USA
[3] Univ Calif Santa Barbara, Dept Mech Engn, Santa Barbara, CA 93106 USA
[4] Univ Aberdeen, Kings Coll, Sch Engn, Aberdeen AB24 3UE, Scotland
[5] INM Leibniz Inst New Mat, Campus D2 2, D-66123 Saarbrucken, Germany
关键词
Inferior vena cava; Valsalva; Compression; Inferior vena cava filter; SHAPE-MEMORY ALLOYS; NUMERICAL SIMULATIONS; FATIGUE; PERFORATION; EXPERIENCE; RETRIEVAL; GEOMETRY; MANEUVER; FRACTURE; STENT;
D O I
10.1007/s10659-021-09850-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We carry out computational simulations of the Valsalva compression of an inferior vena cava (IVC) with a filter implanted in it. We find that when we treat the IVC wall as simply a boundary between 2 fluids and apply an external pressure on the IVC, the deformation magnitudes and patterns do not agree with data in the literature. We conclude that IVC compression is mainly caused by solid bodies (i.e. tissue and organs) compressing the IVC, and develop a model to simulate this phenomenon. We calibrate our model to data in the literature for Valsalva compression with and without an implanted filter. We then use our approach to predict the area reduction of the IVC during breathing when 2 different types of filters are implanted. Not surprisingly, we find that a compliant filter is less able to resist the compression of the IVC during respiration than a stiffer one, and we quantify the difference. We anticipate that, with further development, our model can be used to make assessments of design and testing parameters that can help to avoid fatigue failure of a filter that is subjected to millions of compressions due to breathing.
引用
收藏
页码:383 / 408
页数:26
相关论文
共 50 条
  • [21] Safety and Effectiveness of the Denali Inferior Vena Cava Filter: Intermediate Follow-Up Results
    Reis, Stephen P.
    Kovoor, Jerry
    Sutphin, Patrick D.
    Toomay, Seth
    Trimmer, Clayton
    Pillai, Anil
    Reddick, Mark
    Kalva, Sanjeeva P.
    VASCULAR AND ENDOVASCULAR SURGERY, 2016, 50 (06) : 385 - 390
  • [22] Inferior vena cava filter misplacement caused by the special anatomy of inferior vena cava: A case report
    Yang, Jian
    He, Qi-Fan
    Fan, Bao-Rui
    Jin, Yong -Hai
    ASIAN JOURNAL OF SURGERY, 2023, 46 (12) : 5874 - 5876
  • [23] Suprarenal inferior vena cava filter implantation
    Carrafiello, G.
    Mangini, M.
    Fontana, F.
    Ierardi, A. M.
    Di Massa, A.
    Xhepa, G.
    De Marchi, G.
    Piacentino, F.
    Fugazzola, C.
    RADIOLOGIA MEDICA, 2012, 117 (07): : 1190 - 1198
  • [24] Successful treatment of a child with inferior vena cava thrombosis using a temporary inferior vena cava filter
    Inoue, Y
    Kato, M
    Ohsuka, T
    Morikawa, A
    PEDIATRIC CARDIOLOGY, 2002, 23 (01) : 74 - 76
  • [25] Inferior vena cava filter thrombosis: An overview
    Razi, Murtuza
    Xu, He
    Jianping, Gu
    Ahmed, Mohammed Jameeluddin
    INDIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 7 (04) : 335 - 339
  • [26] Enormous thoracic solitary fibrous tumor with inferior vena cava compression: A case report
    Taha, Abdulsalam Y.
    Mahmood, Darya
    Mohialdeen, Dana
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 25 (03): : 459 - 464
  • [27] Abdominal Aortic Aneurysm With Inferior Vena Cava Compression in Association With Deep Venous Thrombosis
    Moore, Ryan D.
    Rutter, Elizabeth D.
    Zapko, Daniel R.
    Kolade, Victor O.
    Ayyoub, Shadi M.
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2013, 346 (06) : 521 - 522
  • [28] The inferior vena cava filter and complications associated with its use
    Hudak, Marek
    Kosco, Martin
    Dekanova, Lucia
    Pavlikova, Veronika
    Szaboova, Eva
    Rasiova, Maria
    COR ET VASA, 2024, 66 (03) : 335 - 343
  • [29] Inferior vena cava filter penetration into right proximal ureter
    Sherman, Christopher M.
    Rao, Sandhya R.
    Talluri, Sriharsha
    Dwivedi, Amit J.
    Ankem, Murali K.
    CANADIAN JOURNAL OF UROLOGY, 2014, 21 (01) : 7160 - 7162
  • [30] Multicenter investigation of the incidence of inferior vena cava filter fracture
    Jun Koizumi
    Takuya Hara
    Tatsuya Sekiguchi
    Tamaki Ichikawa
    Hiroyuki Tajima
    Naoko Takenoshita
    Masato Tanikake
    Yohsuke Suyama
    Tatsumi Kaji
    Kenichi Kato
    Miyuki Sone
    Yasuaki Arai
    Hiroshi Anai
    Kimihiko Kichikawa
    Hiroyuki Fujieda
    Toshiya Nishibe
    Norikazu Yamada
    Mashio Nakamura
    Takeshi Nakano
    Takeyoshi Kunieda
    Takayuki Kuriyama
    Tsuneaki Sugimoto
    Morimasa Takayama
    Takao Kobayashi
    Shinya Goto
    Minoru Kanazawa
    Masaaki Itou
    Kunio Shirato
    Japanese Journal of Radiology, 2018, 36 : 661 - 668