Purpose. - To determine the correlations between the size of the optic disc and glaucomatous defects in black Africans. Design. - Retrospective observational study. Methods. - The study was conducted over a two-year period from November 2014 to October 2016, based on records of black Togolese patients who had undergone optic nerve head (ONH) OCT or ganglion cell complex OCT for assessment of glaucoma. The population was divided into 3 groups (I, II and III) depending on the size of the ONH. The ONH was considered small (Group I) if its size was less than the mean -1 SD, medium (Group II) if its size was within 1 SD of the mean, and large (Group III) if its size was greater than the mean + 1 SD. Glaucomatous lesions were qualitatively identified on RNFL and or GCC. The ONH parameters were compared in the 3 groups. The Chi-square test was used to compare the percentages, and the t test to compare the means with statistical significance of 5%. The Pearson correlation coefficient (r(2)) was used to measure correlations. Results. - A total of 586 eyes of 298 patients were examined, 314 glaucomatous eyes and 272 healthy eyes. The mean age was 41.0 +/- 15.7 [6; 86] years. There were 159 men vs. 137 women, with a sex ratio of 1.2. The mean surface area of the ONH was 2.80 +/- 0.55 mm(2). Small ONH's (Group I) were defined as a surface area of less than 2.25 mm(2), medium-sized ONH's (Group II) as an area between 2.25 and 3.35 mm(2) and large ONH's (Group III) as an area greater than 3.35 mm(2). Small ONH's represented 14.7%, (86 eyes), medium-sized 68.6% (408 eyes) and large ONH's 16.8% (98 eyes). The mean surface area of the neuroretinal rim, cup, the cup-disc ratio and the RNFL thickness were statistically significant in the 3 groups. Similarly, all these parameters were significant in groups of glaucomatous or non-glaucomatous eyes, except for the surface area of the cup. The RNFL thickness was weakly correlated with the surface area of the ONH (r(2) =0.39), moderately correlated with the surface area of the neuroretinal rim (r(2) =0.57). The surface area of the ONH was strongly correlated with the surface area of the cup (r(2) =0.7). The neuroretinal rim surface area was strongly correlated with the cup-disc ratio (r(2) =0.66). Conclusion. - The size of the ONH was correlated with the size of the cup, but it was not correlated to the surface area of the neuroretinal rim or the thickness of the nerve fibers. Analysis of the RNFL and GCC is essential for the diagnosis, especially in the case of large ONH's. (C) 2018 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:847 / 851
页数:5
相关论文
共 50 条
  • [31] Cerebrospinal fluid pressure and glaucomatous optic disc cupping
    Berdahl, John P.
    Ethier, C. Ross
    Allingham, R. Rand
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (09) : 1289 - 1290
  • [32] Comparison of Disc Analysis Algorithms Provided by Cirrus OCT and Stereo Optic-disc Photography in Normal and Open Angle Glaucoma Patients
    Lee, Marvin
    Yoo, Hyungyu
    Ahn, Jaehong
    CURRENT EYE RESEARCH, 2013, 38 (05) : 605 - 613
  • [33] OCT topographic characteristics of the optic nerve in patients clinically suspected to have large optic disc cupping in Togo
    Maneh, N.
    Ayena, K. D.
    Vonor, K.
    Saa, K. B. Nonon
    Amedome, K. M.
    Dzidzinyo, K. B.
    Ikessieba, C. B.
    Kuaovi, K. R.
    Banla, M.
    Balo, K. P.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2017, 40 (07): : 588 - 591
  • [34] Cerebrospinal fluid pressure and glaucomatous optic disc cupping
    Hayreh, Sohan Singh
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (06) : 721 - 724
  • [35] Measurement of Optic Disc Cup Surface Depth Using Cirrus HD-OCT
    Kim, Young Kook
    Ha, Ahnul
    Lee, Won June
    Jeoung, Jin Wook
    Park, Ki Ho
    JOURNAL OF GLAUCOMA, 2017, 26 (12) : 1072 - 1080
  • [36] Clinical Features of the Optic Disc Melanocytoma and Optic Disc Melanoma
    Aydin, Onur
    Burumcek, Engin
    Arstan, M. Okan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2005, 35 (04): : 352 - 358
  • [37] Determinants of Macular Layers and Optic Disc Characteristics on SD-OCT: The Rhineland Study
    Mauschitz, Matthias M.
    Holz, Frank G.
    Finger, Robert P.
    Breteler, Monique M. B.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (03):
  • [38] Cerebrospinal fluid pressure and glaucomatous optic disc cupping (response to Berdahl and colleagues)
    Sohan Singh Hayreh
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 1291 - 1294
  • [39] Discrimination between normal and glaucomatous eyes with scanning laser polarimetry and optic disc topography: A preliminary report
    Magacho, L
    Marcondes, AM
    Costa, VP
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (03) : 353 - 359
  • [40] Assessment of Early Glaucomatous Optic Neuropathy in the Dog by Spectral Domain Optical Coherence Tomography (SD-OCT)
    Oh, Annie
    Harman, Christine D.
    Koehl, Kristin L.
    Huang, Jiayan
    Teixeira, Leandro B. C.
    Occelli, Laurence M.
    Storey, Eric S.
    Ying, Gui-Shuang
    Komaromy, Andras M.
    MICROMACHINES, 2024, 15 (06)