Optic disc features on OCT in glaucomatous and normal black Africans

被引:1
|
作者
Vonor, K. [1 ,2 ]
Ayena, K. D. [2 ]
Maneh, N. [2 ]
Nononsaa, K. B. [2 ]
Amedome, K. M. [2 ]
Dzidzinyo, K. [2 ]
Santos, M. A. K. [2 ]
Koko, R. A. Kuaovi [3 ]
Banla, M. [2 ]
Balo, K. P. [2 ]
机构
[1] Univ Lome, Fac Sci Sante, Serv Ophtalmol CHR Tsevie, BP 13648, Lome, Togo
[2] Univ Lome, Dept Ophtalmol, Lome, Togo
[3] Cabinet Ophtalmol AFIA, Route Kpalime,07 BP 13648, Lome, Togo
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2018年 / 41卷 / 09期
关键词
Glaucoma; Optic disc; Retinal nerve fibers; OCT; Black African; CENTRAL CORNEAL THICKNESS; NERVE-FIBER LAYER; COHERENCE TOMOGRAPHY; INTRAOCULAR-PRESSURE; HEAD; AGE; CAUCASIANS; AMERICANS; SIZE; RACE;
D O I
10.1016/j.jfo.2018.02.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. - To determine the correlations between the size of the optic disc and glaucomatous defects in black Africans. Design. - Retrospective observational study. Methods. - The study was conducted over a two-year period from November 2014 to October 2016, based on records of black Togolese patients who had undergone optic nerve head (ONH) OCT or ganglion cell complex OCT for assessment of glaucoma. The population was divided into 3 groups (I, II and III) depending on the size of the ONH. The ONH was considered small (Group I) if its size was less than the mean -1 SD, medium (Group II) if its size was within 1 SD of the mean, and large (Group III) if its size was greater than the mean + 1 SD. Glaucomatous lesions were qualitatively identified on RNFL and or GCC. The ONH parameters were compared in the 3 groups. The Chi-square test was used to compare the percentages, and the t test to compare the means with statistical significance of 5%. The Pearson correlation coefficient (r(2)) was used to measure correlations. Results. - A total of 586 eyes of 298 patients were examined, 314 glaucomatous eyes and 272 healthy eyes. The mean age was 41.0 +/- 15.7 [6; 86] years. There were 159 men vs. 137 women, with a sex ratio of 1.2. The mean surface area of the ONH was 2.80 +/- 0.55 mm(2). Small ONH's (Group I) were defined as a surface area of less than 2.25 mm(2), medium-sized ONH's (Group II) as an area between 2.25 and 3.35 mm(2) and large ONH's (Group III) as an area greater than 3.35 mm(2). Small ONH's represented 14.7%, (86 eyes), medium-sized 68.6% (408 eyes) and large ONH's 16.8% (98 eyes). The mean surface area of the neuroretinal rim, cup, the cup-disc ratio and the RNFL thickness were statistically significant in the 3 groups. Similarly, all these parameters were significant in groups of glaucomatous or non-glaucomatous eyes, except for the surface area of the cup. The RNFL thickness was weakly correlated with the surface area of the ONH (r(2) =0.39), moderately correlated with the surface area of the neuroretinal rim (r(2) =0.57). The surface area of the ONH was strongly correlated with the surface area of the cup (r(2) =0.7). The neuroretinal rim surface area was strongly correlated with the cup-disc ratio (r(2) =0.66). Conclusion. - The size of the ONH was correlated with the size of the cup, but it was not correlated to the surface area of the neuroretinal rim or the thickness of the nerve fibers. Analysis of the RNFL and GCC is essential for the diagnosis, especially in the case of large ONH's. (C) 2018 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:847 / 851
页数:5
相关论文
共 50 条
  • [1] Ability of CirrusTM HD-OCT Optic Disc Measurements to Discriminate Between Normal and Glaucomatous Eyes
    Mwanza, J. -C.
    Oakley, J. D.
    Anderson, D. R.
    Budenz, D. L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [2] Influence of Anterior Chamber Depth on Optic Disc Measurements with OCT and HRT 3
    Klamann, M. K. J.
    Gonnermann, J.
    Maier, A-K. B.
    Ruokonen, P.
    Bertelmann, E.
    Torun, N.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2013, 230 (10) : 1029 - 1033
  • [3] SD-OCT Imaging of the Retina and Optic Nerve in Normal and Glaucomatous Cats
    Seo, K.
    Rasmussen, C. A.
    Finch, A. K.
    Xiong, K.
    Kaufman, P. L.
    McLellan, G. J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Fluorescein leakage of the optic disc in glaucomatous optic neuropathy
    Oliver Arend
    Andreas Remky
    Niklas Plange
    Marion Kaup
    Bernard Schwartz
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 659 - 664
  • [5] Fluorescein leakage of the optic disc in glaucomatous optic neuropathy
    Arend, O
    Remky, A
    Plange, N
    Kaup, M
    Schwartz, B
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (07) : 659 - 664
  • [6] Glaucomatous optic neuropathy evaluation project: a standardized internet system for assessing skills in optic disc examination
    Kong, Yu Xiang G.
    Coote, Michael A.
    O'Neill, Evelyn C.
    Gurria, Lulu U.
    Xie, Jing
    Garway-Heath, David
    Medeiros, Felipe A.
    Crowston, Jonathan G.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (04) : 308 - 317
  • [7] Morphometric assessment of normal, suspect and glaucomatous optic discs with Stratus OCT and HRT II
    M E Iliev
    A Meyenberg
    J G Garweg
    Eye, 2006, 20 : 1288 - 1299
  • [8] Morphometric assessment of normal, suspect and glaucomatous optic discs with Stratus OCT and HRT II
    Iliev, M. E.
    Meyenberg, A.
    Garweg, J. G.
    EYE, 2006, 20 (11) : 1288 - 1299
  • [9] Keratometry, optic disc dimensions, and degree and progression of glaucomatous optic nerve damage
    Jonas, Jost B.
    Stroux, Andrea
    Martus, Peter
    Budde, Wido
    JOURNAL OF GLAUCOMA, 2006, 15 (03) : 206 - 212
  • [10] Evaluation of the different methods of optic disc examination in glaucomatous patients
    Hefny, Mostafa M.
    Abd-Elshafik, Mohamed A.
    Gharib, Hesham M.
    Shabaan, Yasmine M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (04) : 279 - 285