摘要
'Standard' or 'extracellular' base excess (SBE) is a modified calculation using one-third the normal hemoglobin concentration. It is a 'CO2-invariant' expression of metabolic acid-base status integrated across interstitial, plasma and erythrocytic compartments (IPE). SBE also integrates conflicting physical chemical influences on metabolic acid-base status. Until recently attempts to quantify individual contributions to SBE, for example the plasma strong ion gap, failed to span the 'CO2-stable' IPE dimension. The first breakthrough was from Anstey, who determined the concentration of unmeasured charged species referenced to the IPE domain using Wooten's physical chemical version of the Van Slyke equation. In this issue Drs Wolf and DeLand present a diagnostic tool based on an IPE model which dissects a version of SBE (BEnet) into nine independent (BEind) components, all referenced to the IPE domain. The reported components are excess/deficits of free water, chloride, albumin, unmeasured ions, sodium, potassium, lactate, 'Ca-Mg' (a composite divalent cation entity), and phosphate. The model also reports individualised volumes of plasma, erythrocytes and interstitial fluid. The tool is an original contribution, but there are concerns. The impact of assuming fixed relationships between arterial and venous acid-base and saturation values in sepsis, anaemia and in differing shock states is unclear. Clinicians are also unlikely to accept that unique, accurate IPE volume determinations can be derived from a single set of blood gas and biochemistry results. Nevertheless, volume determinations aside, the tool is likely to become a valuable addition to the diagnostic armamentarium.
引用
收藏
页码:349 / 352
页数:4
相关论文
共 34 条
[2]   Estimating the net effect of unmeasured ions in human extracellular fluid using a new mathematical model. Part I: Theoretical considerations [J].
Anstey, C. M. .
ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (05) :862-869
[3]   Estimating the net effect of unmeasured ions in human extracellular fluid using a new mathematical model. Part II: Practical issues [J].
Anstey, C. M. .
ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (05) :870-875
[4]   Blood volume determination by the carbon monoxide method using a new delivery system:: Accuracy in critically ill humans and precision in an animal model [J].
Dingley, J ;
Foëx, BA ;
Swart, M ;
Findlay, G ;
DeSouza, PR ;
Wardrop, C ;
Willis, N ;
Smithies, M ;
Little, RA .
CRITICAL CARE MEDICINE, 1999, 27 (11) :2435-2441
[5]  
Doberer D, 2009, INTENSIVE CARE MED
[6]  
Elbers PW, 2008, ANESTHESIOLOGY, V109, pA1436
[7]   CLINICAL USE OF ANION GAP [J].
EMMETT, M ;
NARINS, RG .
MEDICINE, 1977, 56 (01) :38-54
[8]   A PHYSICAL-CHEMICAL APPROACH TO THE ANALYSIS OF ACID-BASE-BALANCE IN THE CLINICAL SETTING [J].
GILFIX, BM ;
BIQUE, M ;
MAGDER, S .
JOURNAL OF CRITICAL CARE, 1993, 8 (04) :187-197
[9]   The place of THAM in the management of acidemia in clinical practice [J].
Holmdahl, MH ;
Wiklund, L ;
Wetterberg, T ;
Streat, S ;
Wahlander, S ;
Sutin, K ;
Nahas, G .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2000, 44 (05) :524-527
[10]   STRONG ION GAP - A METHODOLOGY FOR EXPLORING UNEXPLAINED ANIONS [J].
KELLUM, JA ;
KRAMER, DJ ;
PINSKY, MR .
JOURNAL OF CRITICAL CARE, 1995, 10 (02) :51-55