proFIA: a data preprocessing workflow for flow injection analysis coupled to high-resolution mass spectrometry

被引:15
作者
Delabriere, Alexis [1 ]
Hohenester, Ulli M. [2 ]
Colsch, Benoit [2 ]
Junot, Christophe [2 ]
Fenaille, Francoise [2 ]
Thevenot, Etienne A. [1 ]
机构
[1] CEA, LIST, Lab Data Anal & Syst Intelligence, MetaboHUB, F-91191 Gif Sur Yvette, France
[2] CEA, DRF JOLIOT SPI, Lab Etud Metab Medicaments, MetaboHUB, F-91191 Gif Sur Yvette, France
关键词
ADULT URINARY METABOLOME; HIGH-THROUGHPUT; ELECTROSPRAY-IONIZATION; LC-MS; CHROMATOGRAPHY; IDENTIFICATION; MATRIX; CLASSIFICATION; IMPUTATION; BIOLOGY;
D O I
10.1093/bioinformatics/btx458
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Motivation: Flow Injection Analysis coupled to High-Resolution Mass Spectrometry (FIA-HRMS) is a promising approach for high-throughput metabolomics. FIA-HRMS data, however, cannot be preprocessed with current software tools which rely on liquid chromatography separation, or handle low resolution data only. Results: We thus developed the proFIA package, which implements a suite of innovative algorithms to preprocess FIA-HRMS raw files, and generates the table of peak intensities. The workflow consists of 3 steps: (i) noise estimation, peak detection and quantification, (ii) peak grouping across samples and (iii) missing value imputation. In addition, we have implemented a new indicator to quantify the potential alteration of the feature peak shape due to matrix effect. The preprocessing is fast (less than 15 s per file), and the value of the main parameters (ppm and dmz) can be easily inferred from the mass resolution of the instrument. Application to two metabolomics datasets (including spiked serum samples) showed high precision (96%) and recall (98%) compared with manual integration. These results demonstrate that proFIA achieves very efficient and robust detection and quantification of FIA-HRMS data, and opens new opportunities for high-throughput phenotyping.
引用
收藏
页码:3767 / 3775
页数:9
相关论文
共 45 条
[21]   MATHEMATICAL-MODELING OF FLOW-INJECTION SYSTEMS [J].
KOLEV, SD .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :36-66
[22]   Direct introduction of biological samples into a LTQ-Orbitrap hybrid mass spectrometer as a tool for fast metabolome analysis [J].
Madalinski, Geoffrey ;
Godat, Emmanuel ;
Alves, Sandra ;
Lesage, Denis ;
Genin, Eric ;
Levi, Philippe ;
Labarre, Jean ;
Tabet, Jean-Claude ;
Ezan, Eric ;
Junot, Christophe .
ANALYTICAL CHEMISTRY, 2008, 80 (09) :3291-3303
[23]  
McNaught A.D., 1997, IUPAC COMPENDIUM CHE
[24]  
More J. J., 1978, Proceedings of the Biennial Conference on numerical analysis, P105
[25]  
Morgan M., 2017, BIOCPARALLEL BIOCOND
[26]   Quantitative Mass Spectrometry Independence from Matrix Effects and Detector Saturation Achieved by Flow Injection Analysis with Real-Time Infinite Dilution [J].
Nanita, Sergio C. .
ANALYTICAL CHEMISTRY, 2013, 85 (24) :11866-11875
[27]   Systems biology - Metabonomics [J].
Nicholson, Jeremy K. ;
Lindon, John C. .
NATURE, 2008, 455 (7216) :1054-1056
[28]  
R Development Core Team, 2017, R LANGUAGE ENV STAT
[29]   Annotation of the Human Adult Urinary Metabolome and Metabolite Identification Using Ultra High Performance Liquid Chromatography Coupled to a Linear Quadrupole Ion Trap-Orbitrap Mass Spectrometer [J].
Roux, Aurelie ;
Xu, Ying ;
Heilier, Jean-Francois ;
Olivier, Marie-Francoise ;
Ezan, Eric ;
Tabet, Jean-Claude ;
Junot, Christophe .
ANALYTICAL CHEMISTRY, 2012, 84 (15) :6429-6437
[30]   FLOW-INJECTION ANALYSIS AND CHROMATOGRAPHY - TWINS OR SIBLINGS - PLENARY LECTURE [J].
RUZICKA, J ;
CHRISTIAN, GD .
ANALYST, 1990, 115 (05) :475-486