A Passive Heart Rate Measurement Method Using Camera

被引:6
作者
Cai, Kai [1 ]
Chen, Jianxin [1 ]
Zhang, Lujia [1 ]
Lin, Qingyu [1 ]
Ji, Hui [1 ]
机构
[1] Nanjing Univ Posts & Telecommun, Minist Educ, Key Lab Broadband Wireless Commun & Sensor Networ, Nanjing, Jiangsu, Peoples R China
来源
PROCEEDINGS OF 2018 INTERNATIONAL CONFERENCE ON COMPUTING AND PATTERN RECOGNITION (ICCPR 2018) | 2018年
关键词
Heart Rate Measurement; Euler Video Magnification; Independent Component Analysis; Non-confront;
D O I
10.1145/3232829.3232841
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Heart rate is one of the most important Physiological characteristics related to the health. Recently, the non-contact heart rate measurement has got more attentions. However, these methods only focused on the active measurement. In this paper, we study the non-contact measurement of HR in a passive way which extends its further use into the smart home or e-health. In this system, a RGB camera is used to capture the video images about the objective. For these captured images, we strengthen the color from the captured images with an EVM algorithm, and use KCF algorithm to locate the chosen RoI. After that, the ICA algorithm is utilized to extract the effective signal, and the heart rate is obtained by an ideal band pass filter with the fast Fourier transform. Experimental results showed that our system can measure the heart rate effectively.
引用
收藏
页码:68 / 72
页数:5
相关论文
共 19 条
[1]   Heart Rate Variability Extraction From Videos Signals:ICA vs. EVM Comparison [J].
Alghoul, Karim ;
Alharthi, Saeed ;
Al Osman, Hussein ;
El Saddik, Abdulmotaleb .
IEEE ACCESS, 2017, 5 :4711-4719
[2]  
Allen J., 2007, PHYSL MEASUREMENT, V28
[3]   An ultra low power pulse oximeter sensor based on compressed sensing [J].
Baheti, Pawan K. ;
Garudadri, Harinath .
SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, 2009, :144-148
[4]  
Bosi I, 2016, 2016 INTERNATIONAL MULTIDISCIPLINARY CONFERENCE ON COMPUTER AND ENERGY SCIENCE (SPLITECH), P1
[5]  
Cheng Y., 2015, SHOCK VIB, V2015, P1
[6]   Thermistor at a Distance: Unobtrusive Measurement of Breathing [J].
Fei, Jin ;
Pavlidis, Ioannis .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (04) :988-998
[7]   Contact-free measurement of cardiac pulse based on the analysis of thermal imagery [J].
Garbey, Marc ;
Sun, Nanfei ;
Merla, Arcangelo ;
Pavlidis, Ioannis .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (08) :1418-1426
[8]  
Greneker EF, 1997, IEE CONF PUBL, P150, DOI 10.1049/cp:19971650
[9]   High-Speed Tracking with Kernelized Correlation Filters [J].
Henriques, Joao F. ;
Caseiro, Rui ;
Martins, Pedro ;
Batista, Jorge .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2015, 37 (03) :583-596
[10]   Independent component analysis:: algorithms and applications [J].
Hyvärinen, A ;
Oja, E .
NEURAL NETWORKS, 2000, 13 (4-5) :411-430