Electrochemical adsorptive behavior of some fluoroquinolones at carbon paste electrode

被引:33
作者
El Ries, MA [1 ]
Wassel, AA [1 ]
Ghani, NTA [1 ]
El-Shall, MA [1 ]
机构
[1] Cairo Univ, Fac Sci, Dept Chem, Cairo, Egypt
关键词
D O I
10.2116/analsci.21.1249
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cyclic voltammetry and differential pulse voltammetry were used to explore the adsorption behavior of three antibacterial agents at a carbon paste electrode. The drugs were accumulated on a carbon paste electrode, and a well-defined oxidation peak was obtained in acetate buffer (pH 5.0). The adsorptive stripping response was evaluated as a function of some variables such as the scan rate, pH and accumulation time. A simple, precise, inexpensive and sensitive voltammetric method has been developed for the determination of the cited drugs (Lomefloxacin (LFX), Sparfloxacin hydrochloride (SFX), and Gatifloxacin (GFX)). A linear calibration was obtained from 2 x 10(-7) M to 4 x 10(-5) M for LFX, 2 x 10-7 M to 6 x 10(-5) M for SFX, and GFX. The limits of detection (LOD) were 4.2 x 10(-7), 7 x 10(-7) and 6.6 x 10(-7) M, while the limits of quantification (LOQ) were 1.4 x 10(-6), 2.3 x 10(-6) and 2.2 x 10(-6) M for LFX, SFX, and GFX, respectively. The R. S. D. of five measurements at the 1 x 10(-6) M level were 0.4, 0.5 and 0.3 for LFX, SFX and GFX, respectively. The method was applied to the determination of LFX, SFX and GFX in dilute urine samples and dosage forms, and compared with the HPLC method.
引用
收藏
页码:1249 / 1254
页数:6
相关论文
共 40 条
[1]   A PVC-graphite composite electrode for electroanalytical use. Preparation and some applications [J].
Albertus, F ;
Llerena, A ;
Alpizar, J ;
Cerda, V ;
Luque, M ;
Rios, A ;
Valcarcel, M .
ANALYTICA CHIMICA ACTA, 1997, 355 (01) :23-32
[2]  
Bard A. J., 2001, Electrochemical Methods: Fundamentals and Applications, P168
[3]   Methods of analysis olf 4-quinolone antibacterials [J].
Belal, F ;
Al-Majed, AA ;
Al-Obaid, AM .
TALANTA, 1999, 50 (04) :765-786
[4]   Determination of gatifloxacin in human serum and urine by HPLC [J].
Borner, K ;
Hartwig, H ;
Lode, H .
CHROMATOGRAPHIA, 2000, 52 (Suppl 1) :S105-S107
[5]   DETERMINATION OF LOMEFLOXACIN IN HUMAN PLASMA BY SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH UV DETECTION [J].
CARLUCCI, G ;
CILLI, A ;
LIBERATO, M ;
MAZZEO, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1105-1108
[6]   Analysis of fluoroquinolones in biological fluids by high-performance liquid chromatography [J].
Carlucci, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) :343-367
[7]   New materials for electrochemical sensing .1. Rigid conducting composites [J].
Cespedes, F ;
MartinezFabregas, E ;
Alegret, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (07) :296-304
[8]  
FERNANDES PB, 1989, INT TELESYMPOSIUM QU, P21
[9]   Voltammetric lability of metal complexes at spherical microelectrodes with various radii [J].
Galceran, J ;
Puy, J ;
Salvador, J ;
Cecília, J ;
van Leeuwen, HP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 505 (1-2) :85-94
[10]  
Gosser D.K., 1993, Cyclic voltammetry: simulation and analysis of reaction mechanisms