Convective heat transfer for multiple rows of impinging air jets with small jet-to-jet spacing in a semi-confined channel

被引:74
作者
Shan Yong [1 ]
Zhang Jing-zhou [1 ,2 ]
Xie Gong-nan [3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Jiangsu Prov Key Lab Aerosp Power Syst, Coll Energy & Power Engn, Nanjing 210016, Jiangsu, Peoples R China
[2] Collaborat Innovat Ctr Adv Aeroengine, Beijing 100191, Peoples R China
[3] Northwestern Polytech Univ, Sch Mech Engn, Engn Simulat & Aerosp Comp, Xian 710072, Peoples R China
关键词
Jet impingement; Semi-confined channel; Dense array of multiple-jets; Convective heat transfer; Jet-induced crossflow; ARRAY IMPINGEMENT; STAGGERED ARRAYS; FLOW CHARACTERISTICS; TRANSFER COEFFICIENT; DISTRIBUTIONS; HOLES; GAS;
D O I
10.1016/j.ijheatmasstransfer.2015.03.073
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects of jet-to-jet pitch ratios in both streamwise and spanwise directions (x(n)/d and y(n)/d, ranged from 2 to 5), jet-to-target spacing ratio (z(n)/d, ranged from 2 to 4) and jet array arrangement (inline and staggered) on the jet impingement heat transfer behaviors are experimentally investigated under the jet Reynolds number ranged from 5000 to 25,000. Special attention is paid to examine the dense-array jet impingement behaviors inside a semi-confined channel with one-directional spent air outflow where the jet-induced crossflow is more serious. The detailed surface heat transfer distribution under the densest-array jet impingement inside the semi-confined channel is behaved as the character of a channel-like flow due to strong adjacent jet interference. The strongest jet impingement heat transfer is achieved for the case with x(n)/d = y(n)/d = 3 among the presented jet-to-jet pitch ratios under the same impingement Reynolds number. While evaluating on the base of the same mass flow rate of coolant per unit area of cooled surface, the heat transfer performance of multiple-jets with x(n)/d = y(n)/d = 5 is obviously superior to that of denser multiple-jets array. The uniformity coefficient is not significantly affected by the jet-to-jet pitch investigated in the present study. Besides, the heat transfer performance under z(n)/d = 2 is confirmed to be superior to the other jet-to-target spacing ratios for the dense array of multiple jets. For the multiple-jets with x(n)/d = y(n)/d = 3, the local area-averaged row Nusselt number corresponding to the front rows under staggered array is somewhat higher than that under the inline array. From the fourth row on, the jet-induced crossflow effect behaves more obviously for the staggered array. While for the multiple-jets with x(n)/d = y(n)/d = 5, the heat transfer for the staggered array seems to be somewhat superior to that of inline array. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:832 / 842
页数:11
相关论文
共 44 条
[1]  
Bailey J.C., 2002, 200230473 ASME
[2]   LOCAL HEAT-TRANSFER TO STAGGERED ARRAYS OF IMPINGING CIRCULAR AIR JETS [J].
BEHBAHANI, AI ;
GOLDSTEIN, RJ .
JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1983, 105 (02) :354-360
[3]   Heat transfer to a row of impinging jets in consideration of optimization [J].
Brevet, P ;
Dejeu, C ;
Dorignac, E ;
Jolly, M ;
Vullierme, JJ .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (20) :4191-4200
[4]   Enhancement of Impingement Cooling in a High Cross Flow Channel Using Shaped Impingement Cooling Holes [J].
Chambers, Andrew C. ;
Gillespie, David R. H. ;
Ireland, Peter T. ;
Kingston, Robert .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2010, 132 (02)
[5]   Flow characteristics and heat transfer performances of a semiconfined impinging array of jets: effect of nozzle geometry [J].
Dano, BPE ;
Liburdy, JA ;
Kanokjaruvijit, K .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (3-4) :691-701
[6]   Experimental investigation of local heat transfer distribution on smooth and roughened surfaces under an array of angled impinging jets [J].
El-Gabry, LA ;
Kaminski, DA .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2005, 127 (03) :532-544
[7]   HEAT-TRANSFER CHARACTERISTICS FOR JET ARRAY IMPINGEMENT WITH INITIAL CROSS-FLOW [J].
FLORSCHUETZ, LW ;
METZGER, DE ;
SU, CC .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1984, 106 (01) :34-41
[8]   FLOW DISTRIBUTIONS AND DISCHARGE COEFFICIENT EFFECTS FOR JET ARRAY IMPINGEMENT WITH INITIAL CROSS-FLOW [J].
FLORSCHUETZ, LW ;
ISODA, Y .
JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1983, 105 (02) :296-304
[9]   STREAMWISE FLOW AND HEAT-TRANSFER DISTRIBUTIONS FOR JET ARRAY IMPINGEMENT WITH CROSS-FLOW [J].
FLORSCHUETZ, LW ;
TRUMAN, CR ;
METZGER, DE .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1981, 103 (02) :337-342
[10]  
Floschuetz L.W., 1987, ASME J HEAT TRANSFER, V109, P74