Application of silver solid amalgam electrodes in electrochemical detection of DNA damage

被引:3
作者
Svitkova, Veronika [1 ]
Nemcekova, Katarina [1 ]
Vyskocil, Vlastimil [2 ]
机构
[1] Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Inst Analyt Chem, Bratislava 81237, Slovakia
[2] Charles Univ Prague, Fac Sci, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Prague 12843, Czech Republic
关键词
DNA damage; UV radiation; Amalgam electrode; Electrochemical biosensor; Methylene blue; CDS QUANTUM DOTS; METHYLENE-BLUE; VOLTAMMETRIC DETERMINATION; STYRENE OXIDE; UV-RADIATION; BIOSENSOR; LABEL; BEHAVIOR; SENSOR; FILMS;
D O I
10.1007/s00216-022-03917-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a mercury meniscus-modified silver solid amalgam electrode was used for the first time for the detection of UV-induced DNA damage. The integrity of the double-stranded DNA (dsDNA) layer was detected indirectly using the evaluation of the methylene blue reduction within its accumulation into dsDNA after the UV irradiation of the biosensor surface with two different wavelengths (254 nm and 365 nm), monitored by differential pulse voltammetry. Moreover, a simple electrochemical characterization of the biosensor surface was performed using cyclic voltammetry of the redox indicator hexaammineruthenium chloride (RuHex) present in the solution. Electrochemical impedance spectroscopy (EIS) was used in both cases for the verification of results. Individual electrochemical signals depend on the time of biosensor exposure to UV irradiation as well as on the selected wavelengths and are different for both used types of dsDNA (salmon sperm and calf thymus). The highest degradation degree up to 60% was observed using sensitive EIS of methylene blue after 10 min irradiation of the biosensor at 254 nm. The use of RuHex seems to be less sensitive for the detection of dsDNA structural changes, when the degradation degree up to 40% was observed, using EIS at the same conditions.
引用
收藏
页码:5435 / 5444
页数:10
相关论文
共 50 条
[11]   Developing an elegant and integrated electrochemical-theoretical approach for detection of DNA damage induced by 4-nonylphenol [J].
Ghanbari, Kazhal ;
Roshani, Mahmoud ;
Goicoechea, Hector C. ;
Jalalvand, Ali R. .
HELIYON, 2019, 5 (10)
[12]   Electrodeposited silver amalgam particles on pyrolytic graphite in (spectro)electrochemical detection of 4-nitrophenol, DNA and green fluorescent protein [J].
Sebest, Peter ;
Fojt, Lukas ;
Ostatna, Veronika ;
Fojta, Miroslav ;
Danhel, Ales .
BIOELECTROCHEMISTRY, 2020, 132 (132)
[13]   Impedimetric Detection of DNA Damage with the Sensor Based on Silver Nanoparticles and Neutral Red [J].
Kuzin, Yury ;
Porfireva, Anna ;
Stepanova, Veronika ;
Evtugyn, Vladimir ;
Stoikov, Ivan ;
Evtugyn, Gennady ;
Hianik, Tibor .
ELECTROANALYSIS, 2015, 27 (12) :2800-2808
[14]   Hydroxyapatite Nanoparticles Modified Graphite Electrodes for Electrochemical DNA Detection [J].
Erdem, Arzum ;
Congur, Gulsah .
ELECTROANALYSIS, 2018, 30 (01) :67-74
[15]   Electrochemical behavior of folic acid on mercury meniscus modified silver solid amalgam electrode [J].
Bandzuchova, L. ;
Selesovska, R. ;
Navratil, T. ;
Chylkova, J. .
ELECTROCHIMICA ACTA, 2011, 56 (05) :2411-2419
[16]   Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samples [J].
Filho, Danielle Goncalves ;
de Souza, Djenaine .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2021, 32 (07) :1456-1466
[17]   Electrochemical detection of free chlorine at inkjet printed silver electrodes [J].
Jovic, Milica ;
Cortes-Salazar, Fernando ;
Lesch, Andreas ;
Amstutz, Veronique ;
Bi, Hongyan ;
Girault, Hubert H. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 756 :171-178
[18]   Electrochemical Biosensors Based on Silver Solid Amalgam for Analysis in Flow Systems [J].
Josypcuk, Oksana ;
Barek, Jiri ;
Josypcuk, Bohdan .
XXXV MODERNI ELEKTROCHEMICKE METODY, 2015, :90-94
[19]   Silver Solid Amalgam Electrode as a Tool for Monitoring the Electrochemical Reduction of Hydroxocobalamin [J].
Bandzuchova, Lenka ;
Selesovska, Renata ;
Navratil, Tomas ;
Chylkova, Jaromira .
ELECTROANALYSIS, 2013, 25 (01) :213-222
[20]   Electrochemical DNA sensors for detection of DNA damage [J].
Diculescu, VC ;
Paquim, AMC ;
Brett, AMO .
SENSORS, 2005, 5 (6-10) :377-393