A luminol-based micro-flow-injection electrochemiluminescent system to determine reactive oxygen species

被引:23
作者
Chen Ming [1 ]
Wei Xiuhua [1 ]
Tu Yifeng [1 ]
机构
[1] Soochow Univ, Dept Chem, Inst Analyt Chem, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
Flow injection analysis; Electrochemiluminescence; Reactive oxygen species; Luminal; Water sample; HYDROGEN-PEROXIDE; ELECTROGENERATED CHEMILUMINESCENCE; HORSERADISH-PEROXIDASE; SCAVENGING CAPACITY; OPTICAL SENSORS; WATERS; H2O2; METHODOLOGIES; ELECTRODES; CHEMISTRY;
D O I
10.1016/j.talanta.2011.06.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection analysis (FIA) system with electrochemiluminescent (ECL) detection has been established. Based on a specially designed flow-through ECL cell with a very simple structure, the system possesses rapid response and high sensitivity. With luminol as the ECL reagent, the response of hydrogen peroxide (H(2)O(2)) was investigated on the developed FIA-ECL system. After optimizing the experimental conditions, such as the electric parameters, the buffer condition and the flow rate, it was demonstrated that the developed FIA-ECL system works well for quantified assays. Compared with reported works, the present results indicate that the developed FIA-ECL system has the lowest limit of detection (S/N = 3) of 3.0 x 10(-9) mol/L for H(2)O(2), which is equal to the level of chemiluminescence (CL). The developed system was successfully used to monitor the yield of reactive oxygen species (ROSs) in water vapour during the work of an ultrasonic humidifier with H(2)O(2) as index. And the amount of ROSs in some other real samples, including tap water, drinking water and river water was detected with recoveries from 92.0% to 106%. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1304 / 1309
页数:6
相关论文
共 47 条
[31]   Applications of the luminol chemiluminescent reaction in analytical chemistry [J].
Marquette, Christophe A. ;
Blum, Loic J. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (03) :546-554
[32]   Chemiluminescence biosensors using tris(2,2'-bipyridyl)ruthenium(II) and dehydrogenases immobilized in cation exchange polymers [J].
Martin, AF ;
Nieman, TA .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (06) :479-489
[33]   ANALYTICAL APPLICATIONS OF CHEMILUMINESCENCE [J].
MENDENHALL, GD .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1977, 16 (04) :225-232
[34]   Reactivation of horseradish peroxidase with imidazole for continuous determination of hydrogen peroxide using a microflow injection-chemiluminescence detection system [J].
Nozaki, O ;
Kawamoto, H .
LUMINESCENCE, 2003, 18 (04) :203-206
[35]   An improved chemiluminescence method for hydrogen peroxide determination in plant tissues [J].
Pérez, FJ ;
Rubio, S .
PLANT GROWTH REGULATION, 2006, 48 (01) :89-95
[36]   DETERMINATION OF HYDROGEN-PEROXIDE IN SEA-WATER BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
PRICE, D ;
WORSFOLD, PJ ;
MANTOURA, RFC .
ANALYTICA CHIMICA ACTA, 1994, 298 (01) :121-128
[37]   Electrochemiluminescence (ECL) [J].
Richter, MM .
CHEMICAL REVIEWS, 2004, 104 (06) :3003-3036
[38]   ELECTROCHEMILUMINESCENCE OF HYDROGEN-PEROXIDE LUMINOL AT A CARBON ELECTRODE [J].
SAKURA, S .
ANALYTICA CHIMICA ACTA, 1992, 262 (01) :49-57
[39]   Electrogeneration of polyluminol and chemiluminescence for new disposable reagentless optical sensors [J].
Sassolas, Audrey ;
Blum, Loic J. ;
Leca-Bouvier, Beatrice D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (03) :865-871
[40]  
Segundo MA, 2011, METHODS MOL BIOL, V704, P91, DOI 10.1007/978-1-61737-964-2_8