Radiation hardness studies of CdTe thin films for clinical high-energy photon beam detectors

被引:8
|
作者
Shvydka, Diana [1 ]
Parsai, E. I. [1 ]
Kang, J. [1 ]
机构
[1] Univ Toledo, Dept Radiat Oncol, Toledo, OH 43614 USA
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2008年 / 586卷 / 02期
关键词
CdTe; radiation hardness; X-ray detectors; portal imagers; polycrystalline semiconductors;
D O I
10.1016/j.nima.2007.11.017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In radiation oncology applications, the need for higher-quality images has been driven by recent advances in radiation delivery systems that require online imaging. The existing electronic imaging devices commonly used to acquire portal images implement amorphous silicon (a-Si) detector, which exhibits poor image quality. Efforts for improvement have mostly been in the areas of noise and scatter reduction through software. This has not been successful due to inherent shortcomings of a-Si material. Cadmium telluride (CdTe) semiconductor has long been recognized as highly suitable for use in X-ray detectors in both spectroscopic and imaging applications. Development of such systems has mostly concentrated on single crystal CdTe. Recent advances in thin-film deposition technology suggest replacement of crystalline material with its polycrystalline counterpart, offering case of large-area device fabrication and achievement of higher resolution as well as a favorable cost difference. While bulk CdTe material was found to have superior radiation hardness, thin films have not been evaluated from that prospective, in particular under high-energy photon beam typical of radiation treatment applications. We assess the performance of thin-film CdTe devices utilizing 6 MeV photon beam and find no consistent trend for material degradation under doses far exceeding the typical radiation therapy detector lifetime dose. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:169 / 173
页数:5
相关论文
共 50 条
  • [31] SIMULATION OF A HIGH-ENERGY ELECTRON BEAM TRANSMISSION THROUGH TITANIUM AND KAPTON® THIN FILMS
    Malykhina, Tetiana, V
    Karpus, Stepan G.
    Shopen, Oleg O.
    Prystupa, Valerii, I
    EAST EUROPEAN JOURNAL OF PHYSICS, 2021, (04): : 124 - 129
  • [32] Thermoelectric Generators from AgBiTe and AgSbTe Thin Films Modified by High-Energy Beam
    S. Budak
    S. Guner
    C. Muntele
    D. Ila
    Journal of Electronic Materials, 2015, 44 : 1884 - 1889
  • [33] Enhanced high-energy proton radiation hardness of ZnO thin-film transistors with a passivation layer
    Lee, Yongsu
    Lee, Hae-Won
    Kim, Su Jin
    Park, Jeong Min
    Lee, Byoung Hun
    Kang, Chang Goo
    NANO CONVERGENCE, 2025, 12 (01):
  • [34] Radiation damage in silicon detectors for high-energy physics experiments
    Bruzzi, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 960 - 971
  • [35] Stability issues of high-energy resolution diode type CdTe nuclear radiation detectors in a long-term operation
    Niraula, M
    Nakamura, A
    Aoki, T
    Tomita, Y
    Hatanaka, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 491 (1-2): : 168 - 175
  • [36] Response of neutron detectors to high-energy mixed radiation fields
    Mayer, S.
    Forkel-Wirth, D.
    Fuerstner, M.
    Menzel, H. G.
    Mueller, M. J.
    Perrin, D.
    Theis, C.
    Vincke, H.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 289 - 292
  • [37] DOSIMETRY STUDIES OF A HIGH-ENERGY NEUTRON BEAM
    BAARLI, J
    SULLIVAN, AH
    PHYSICS IN MEDICINE AND BIOLOGY, 1969, 14 (02): : 269 - &
  • [38] DIGITAL PROCESSING OF HIGH-ENERGY PHOTON-BEAM IMAGES
    MEERTENS, H
    MEDICAL PHYSICS, 1985, 12 (01) : 111 - 113
  • [39] MICRODOSIMETRY OF A CLINICAL HIGH-ENERGY NEUTRON BEAM
    DURHAM, JS
    BLUE, TE
    WEHRING, BW
    BLUE, JW
    ROBERTS, WK
    HEALTH PHYSICS, 1984, 47 (01): : 192 - 192
  • [40] OUTPUT FACTOR CONSTITUENTS OF A HIGH-ENERGY PHOTON-BEAM
    LUXTON, G
    ASTRAHAN, MA
    MEDICAL PHYSICS, 1988, 15 (01) : 88 - 91