Spatiotemporal magnetic field monitoring for MR

被引:173
作者
Barmet, Christoph
De Zanche, Nicola
Pruessmann, Klaas P. [1 ]
机构
[1] Univ Zurich, Inst Biomed Engn, ETH, Dept Informat Technol & Elect Engn, CH-8092 Zurich, Switzerland
关键词
eddy current; gradient delay; magnetic field evolution; EPI; spiral;
D O I
10.1002/mrm.21603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR experiments frequently rely on signal encoding by the application of magnetic fields that vary in both space and time. The accurate interpretation of the resulting signals often requires knowledge of the exact spatiotemporal field evolution during the experiment. To better fulfill this need, a new approach is presented that enables measuring the field evolution concurrently with any MR sequence. Miniature NMR probes are used to monitor the MR phase evolution around the object under investigation. Based on these data, a global phase model is calculated that can then be used as a basis for processing the actual image or spectroscopic data. The new method is demonstrated by MRI of a phantom, using spin-warp, spiral, and EPI trajectories. Throughout, the monitoring results enabled highly accurate image reconstruction, even in the presence of massive gradient imperfections.
引用
收藏
页码:187 / 197
页数:11
相关论文
共 43 条
[1]   ANALYSIS OF EDDY CURRENTS IN NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
AHN, CB ;
CHO, ZH .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (01) :149-163
[2]   Elimination of eddy current artifacts in diffusion-weighted echo-planar images: The use of bipolar gradients [J].
Alexander, AL ;
Tsuruda, JS ;
Parker, DL .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :1016-1021
[3]   Gradient characterization using a Fourier-transform technique [J].
Alley, MT ;
Glover, GH ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :581-587
[4]   CORRECTION OF PHASE WRAPPING IN MAGNETIC-RESONANCE IMAGING [J].
AXEL, L ;
MORTON, D .
MEDICAL PHYSICS, 1989, 16 (02) :284-287
[5]  
BARMET C, P ISMRM 2007 BERL, P36
[6]   Rapid gridding reconstruction with a minimal oversampling ratio [J].
Beatty, PJ ;
Nishimura, DG ;
Pauly, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (06) :799-808
[7]   Improved k-space trajectory measurement with signal shifting [J].
Beaumont, Marine ;
Lamalle, Laurent ;
Segebarth, Christoph ;
Barbier, Emmanuel L. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (01) :200-205
[8]   Consistent fat suppression with compensated spectral-spatial pulses [J].
Block, W ;
Pauly, J ;
Kerr, A ;
Nishimura, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :198-206
[9]   TEMPORAL AND SPATIAL-ANALYSIS OF FIELDS GENERATED BY EDDY CURRENTS IN SUPERCONDUCTING MAGNETS - OPTIMIZATION OF CORRECTIONS AND QUANTITATIVE CHARACTERIZATION OF MAGNET GRADIENT SYSTEMS [J].
BOESCH, C ;
GRUETTER, R ;
MARTIN, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (02) :268-284
[10]   CORRECTION OF EDDY-CURRENT-INDUCED B0 SHIFTS BY RECEIVER REFERENCE-PHASE MODULATION [J].
CROZIER, S ;
ECCLES, CD ;
BECKEY, FA ;
FIELD, J ;
DODDRELL, DM .
JOURNAL OF MAGNETIC RESONANCE, 1992, 97 (03) :661-665