Corona discharge in a cylindrical triode charger for unipolar diffusion aerosol charging

被引:19
作者
Intra, Panich [1 ]
机构
[1] Rajamangala Univ Technol Lanna, Coll Integrated Sci & Technol, Res Unit Electrostat Applicat Energy & Environm, Chiang Mai 50220, Thailand
关键词
Aerosol; Corona discharge; Unipolar charger; Diffusion charging; EFFICIENCY; PARTICLES;
D O I
10.1016/j.elstat.2011.11.007
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A cylindrical triode charger for unipolar diffusion charging of aerosol particles was designed, constructed, and evaluated. The corona discharge characteristics were studied in this cylindrical triode charger. For the process the current-voltage characteristics were determined, as were the ion number concentration, the nit product, and the mean charge per particle as a function of particle diameter. The discharge and charging currents, and ion number concentration in the charging zone of the charger increased monotonically with corona voltage. The negative corona had a higher current than the positive corona. At the same corona voltage, the ion number concentration in the discharge zone was larger than the charging current for positive and negative coronas, with values of about 197 and 32 times and 645 and 99 times for the ion-driving voltages of 0 and 310 V, respectively. The average ion penetration for positive and negative coronas was 0.64 and 0.19% and 3.62 and 1.93% for the ion-driving voltages of 0 V and 310 V, respectively. The higher flow rate, shorter residence time, gave a lower N(i)t product. By calculation 14% of charged particles of 10 nm in diameter were lost to the outer cylinder because of the electrostatic field effect. The charger does not use a sheath of air flow along the walls or the perforated screen opening, it has low diffusion and space charge losses due to the short column charging zone, and is a low complexity and inexpensive system. It worked as well as more sophisticated and expensive commercially available chargers. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:136 / 143
页数:8
相关论文
共 18 条
[1]   Effect of free electrons on nanoparticle charging in a negative direct current corona charger [J].
Aliat, A. ;
Tsai, C. -J. ;
Hung, C. -T. ;
Wu, J. -S. .
APPLIED PHYSICS LETTERS, 2008, 93 (15)
[2]   Implementation of Fuchs' model of ion diffusion charging of nanoparticles considering the electron contribution in dc-corona chargers in high charge densities [J].
Aliat, A. ;
Hung, C. T. ;
Tsai, C. J. ;
Wu, J. S. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2009, 42 (12)
[3]  
Alonso M, 2008, AEROSOL AIR QUAL RES, V8, P366
[4]   Electrostatic characterisation of corona-wire aerosol chargers [J].
Biskos, G ;
Reavell, K ;
Collings, N .
JOURNAL OF ELECTROSTATICS, 2005, 63 (01) :69-82
[5]   PERFORMANCE OF A UNIPOLAR SQUARE-WAVE DIFFUSION CHARGER WITH VARIABLE NT-PRODUCT [J].
BUSCHER, P ;
SCHMIDTOTT, A ;
WIEDENSOHLER, A .
JOURNAL OF AEROSOL SCIENCE, 1994, 25 (04) :651-663
[6]   Modeling and Validation of Nanoparticle Charging Efficiency of a Single-Wire Corona Unipolar Charger [J].
Chien, Chih-Liang ;
Tsai, Chuen-Jinn ;
Chen, Hui-Lin ;
Lin, Guan-Yu ;
Wu, Jong-Shinn .
AEROSOL SCIENCE AND TECHNOLOGY, 2011, 45 (12) :1468-1479
[7]  
Hewitt G.W., 1957, Trans. Am. Inst. Elect. Engrs, V76, P300, DOI DOI 10.1109/TCE.1957.6372672
[8]  
Hinds W. C, 1999, AEROSOL TECHNOLOGY
[9]   Use of electrostatic precipitation for excess ion trapping in an electrical aerosol detector [J].
Intra, Panich ;
Tippayawong, Nakorn .
JOURNAL OF ELECTROSTATICS, 2011, 69 (04) :320-327
[10]   An Overview of Unipolar Charger Developments for Nanoparticle Charging [J].
Intra, Panich ;
Tippayawong, Nakorn .
AEROSOL AND AIR QUALITY RESEARCH, 2011, 11 (02) :187-209