Fiber cavity ring-down refractive index sensor

被引:65
作者
Ni, N. [1 ]
Chan, C. C. [1 ]
Xia, L. [2 ]
Shum, P. [2 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Div Bioengn, Singapore 637457, Singapore
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 637553, Singapore
关键词
cavity ring-down (CRD); long-period grating (LPG); refractive index sensor;
D O I
10.1109/LPT.2008.926866
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An exploratory study on a novel fiber long-period grating (LPG) cavity ring-down refractive index sensor is conducted. By detecting the ring-down curves at different ambient refractive index levels, the performances of the LPG sensor are investigated. The experimental results demonstrate by using this sensing setup the change of the refractive index in 1.35-1.43 region could be effectively detected. © 2008 IEEE.
引用
收藏
页码:1351 / 1353
页数:3
相关论文
共 12 条
[1]   Optical fiber long-period grating sensors [J].
Bhatia, V ;
Vengsarkar, AM .
OPTICS LETTERS, 1996, 21 (09) :692-694
[2]   Temperature-insensitive and strain-insensitive long-period grating sensors for smart structures [J].
Bhatia, V ;
Campbell, DK ;
Sherr, D ;
DAlberto, TG ;
Zabaronick, NA ;
TenEyck, GA ;
Murphy, KA ;
Claus, RO .
OPTICAL ENGINEERING, 1997, 36 (07) :1872-1876
[3]   Starch synthesis in the cereal endosperm [J].
James, MG ;
Denyer, K ;
Myers, AM .
CURRENT OPINION IN PLANT BIOLOGY, 2003, 6 (03) :215-222
[4]   Displacements of the resonant peaks of a long-period fiber grating induced by a change of ambient refractive index [J].
Lee, BH ;
Liu, Y ;
Lee, SB ;
Choi, SS ;
Jang, JN .
OPTICS LETTERS, 1997, 22 (23) :1769-1771
[5]   Cavity ring-down long-10.1088/0957-0233/18/10/s14period fibre grating strain sensor [J].
Ni, N. ;
Chan, C. C. ;
Dong, X. Y. ;
Sun, J. ;
Shum, P. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (10) :3135-3138
[6]   Cavity-enhanced spectroscopy in fiber cavities [J].
Stewart, G ;
Atherton, K ;
Culshaw, B .
OPTICS LETTERS, 2004, 29 (05) :442-444
[7]   An investigation of an optical fibre amplifier loop for intra-cavity and ring-down cavity loss measurements [J].
Stewart, G ;
Atherton, K ;
Yu, HB ;
Culshaw, B .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (07) :843-849
[8]   Single-cell detection by cavity ring-down spectroscopy [J].
Tarsa, PB ;
Wist, AD ;
Rabinowitz, P ;
Lehmann, KK .
APPLIED PHYSICS LETTERS, 2004, 85 (19) :4523-4525
[9]   Cavity ringdown strain gauge [J].
Tarsa, PB ;
Brzozowski, DM ;
Rabinowitz, P ;
Lehmann, KK .
OPTICS LETTERS, 2004, 29 (12) :1339-1341
[10]   Fiber ringdown pressure sensors [J].
Wang, CJ ;
Scherrer, ST .
OPTICS LETTERS, 2004, 29 (04) :352-354