Prospective and retrospective motion correction in diffusion magnetic resonance imaging of the human brain

被引:51
作者
Kober, Tobias [1 ,2 ,3 ,4 ]
Gruetter, Rolf [2 ,3 ,5 ]
Krueger, Gunnar [4 ]
机构
[1] Ecole Polytech Fed Lausanne, LIFMET CIBM, Stn 6, Lab Funct & Metab Imaging, CH-1015 Lausanne, Switzerland
[2] CHU Vaudois, Dept Radiol, Lausanne, Switzerland
[3] Univ Lausanne, CH-1015 Lausanne, Switzerland
[4] Siemens Schweiz AG, Healthcare Sector IM&WS S, Renens, Switzerland
[5] Univ Geneva, Dept Radiol, CH-1211 Geneva 4, Switzerland
关键词
MRI; DTI; HARDI; Motion detection; FID navigators; Brain imaging; Multi-coil arrays; ECHO-PLANAR; NAVIGATOR ECHOES; WEIGHTED MRI; PHASE CORRECTION; TRACKING SYSTEM; PULSE SEQUENCE; CLINICAL DTI; ACUTE STROKE; HEAD MOTION; SPIN-ECHO;
D O I
10.1016/j.neuroimage.2011.07.004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively - or optionally retrospectively - correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity >= 92%, specificity > 98%). Motion detection triggered an additional image volume acquisition with b = 0 s/mm(2) which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:389 / 398
页数:10
相关论文
共 61 条
[1]  
ALEXANDER A, 2006, ANN M ISMRM, P858
[2]  
Atkinson D, 2000, MAGN RESON MED, V44, P101, DOI 10.1002/1522-2594(200007)44:1<101::AID-MRM15>3.0.CO
[3]  
2-S
[4]   Diffusion-weighted imaging of the spinal cord: Interleaved echo-planar imaging is superior to fast spin-echo [J].
Bammer, R ;
Augustin, M ;
Prokesch, RW ;
Stollberger, R ;
Fazekas, F .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) :364-373
[5]   MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[6]  
BENNER T, 2011, MAGN RESON MED, V65
[7]   Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging [J].
Brau, ACS ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) :263-270
[8]   Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging [J].
Breuer, FA ;
Blaimer, M ;
Heidemann, RM ;
Mueller, MF ;
Griswold, MA ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :684-691
[9]   Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes [J].
Butts, K ;
deCrespigny, A ;
Pauly, JM ;
Moseley, M .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :763-770
[10]   Isotropic diffusion-weighted and spiral-navigated interleaved EPI for routine imaging of acute stroke [J].
Butts, K ;
Pauly, J ;
deCrespigny, A ;
Moseley, M .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :741-749