Normal values of spleen stiffness in healthy children assessed by acoustic radiation force impulse imaging (ARFI): comparison between two ultrasound transducers

被引:17
作者
Canas, Teresa [1 ]
Fontanilla, Teresa [1 ]
Miralles, Maria [1 ]
Macia, Araceli [2 ]
Malalana, Ana [3 ]
Roman, Enriqueta [3 ]
机构
[1] Hosp Puerta de Hierro Majadahonda, Dept Radiol, Madrid, Spain
[2] UNED, Dept Methodol, Madrid 28040, Spain
[3] Hosp Puerta de Hierro Majadahonda, Dept Pediat, Madrid, Spain
关键词
Child; Acoustic radiation force impulse imaging; Ultrasound; Spleen; Elastography; Shear wave velocity; Reference values; CHRONIC HEPATITIS-B; LIVER FIBROSIS; TRANSIENT ELASTOGRAPHY; NONINVASIVE ASSESSMENT; ESOPHAGEAL-VARICES;
D O I
10.1007/s00247-015-3306-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Portal hypertension, a major complication of hepatic fibrosis, can affect the stiffness of the spleen. To suggest normal values of spleen stiffness determined by acoustic radiation force impulse imaging in healthy children and to compare measurements using two different US probes. In a prospective study, 60 healthy children between 1 day and 14 years of age were assigned to four age groups with 15 children in each. Measurements were performed using two transducers (convex 4C1 and linear 9L4), and 10 measurements were obtained in each child, 5 with each probe. The mean splenic shear wave velocities were 2.17 m/s (SD 0.35, 95% CI 2.08-2.26) with the 4C1 probe and 2.15 m/s (SD 0.23, 95% CI 2.09-2.21) with the 9L4 probe (not significant). We found normal values for spleen stiffness with no difference in the mean values obtained using two types of US transducers, but with higher variability using a convex compared to a linear transducer.
引用
收藏
页码:1316 / 1322
页数:7
相关论文
共 25 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Can ARFI elastography predict the presence of significant esophageal varices in newly diagnosed cirrhotic patients? [J].
Bota, Simona ;
Sporea, Ioan ;
Sirli, Roxana ;
Focsa, Mircea ;
Popescu, Alina ;
Danila, Mirela ;
Strain, Mihnea .
ANNALS OF HEPATOLOGY, 2012, 11 (04) :519-525
[3]  
Bota S, 2010, MED ULTRASON, V12, P213
[4]   Noninvasive assessment of liver fibrosis via spleen stiffness measurement using acoustic radiation force impulse sonoelastography in patients with chronic hepatitis B or C [J].
Chen, S. -H. ;
Li, Y. -F. ;
Lai, H. -C. ;
Kao, J. -T. ;
Peng, C. -Y. ;
Chuang, P. -H. ;
Su, W. -P. ;
Chiang, I. -P. .
JOURNAL OF VIRAL HEPATITIS, 2012, 19 (09) :654-663
[5]   Transient elastography for predicting esophageal/gastric varices in children with biliary atresia [J].
Chongsrisawat, Voranush ;
Vejapipat, Paisarn ;
Siripon, Nipaporn ;
Poovorawan, Yong .
BMC GASTROENTEROLOGY, 2011, 11
[6]   NORMAL VALUES OF LIVER SHEAR WAVE VELOCITY IN HEALTHY CHILDREN ASSESSED BY ACOUSTIC RADIATION FORCE IMPULSE IMAGING USING A CONVEX PROBE AND A LINEAR PROBE [J].
Fontanilla, Teresa ;
Canas, Teresa ;
Macia, Araceli ;
Alfageme, Marta ;
Gutierrez Junquera, Carolina ;
Malalana, Ana ;
Luz Cilleruelo, Maria ;
Roman, Enriqueta ;
Miralles, Maria .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (03) :470-477
[7]   Performance of Acoustic Radiation Force Impulse imaging for the staging of liver fibrosis: a pooled meta-analysis [J].
Friedrich-Rust, M. ;
Nierhoff, J. ;
Lupsor, M. ;
Sporea, I. ;
Fierbinteanu-Braticevici, C. ;
Strobel, D. ;
Takahashi, H. ;
Yoneda, M. ;
Suda, T. ;
Zeuzem, S. ;
Herrmann, E. .
JOURNAL OF VIRAL HEPATITIS, 2012, 19 (02) :E212-E219
[8]   Noninvasive diagnostic method for idiopathic portal hypertension based on measurements of liver and spleen stiffness by ARFI elastography [J].
Furuichi, Yoshihiro ;
Moriyasu, Fuminori ;
Taira, Junichi ;
Sugimoto, Katsutoshi ;
Sano, Takatomo ;
Ichimura, Shigeki ;
Miyata, Yuki ;
Imai, Yasuharu .
JOURNAL OF GASTROENTEROLOGY, 2013, 48 (09) :1061-1068
[9]   Acoustic Radiation Force Impulse (ARFI) technique in ultrasound with Virtual Touch tissue quantification of the upper abdomen [J].
Gallotti, A. ;
D'Onofrio, M. ;
Mucelli, R. Pozzi .
RADIOLOGIA MEDICA, 2010, 115 (06) :889-897
[10]   Noninvasive Assessment of Liver Fibrosis with Acoustic Radiation Force Impulse Imaging: Increased Liver and Splenic Stiffness in Patients with Liver Fibrosis and Cirrhosis [J].
Grgurevic, I. ;
Cikara, I. ;
Horvat, J. ;
Lukic, I. K. ;
Heinzl, R. ;
Banic, M. ;
Kujundzic, M. ;
Brkljacic, B. .
ULTRASCHALL IN DER MEDIZIN, 2011, 32 (02) :160-166