Outcomes and complications of transcatheter aortic valve replacement using a balloon expandable valve according to the Valve Academic Research Consortium (VARC) guidelines

被引:96
|
作者
Gurvitch, Ronen [1 ]
Toggweiler, Stefan [1 ]
Willson, Alexander B. [1 ]
Wijesinghe, Namal [1 ]
Cheung, Anson [1 ]
Wood, David A. [1 ]
Ye, Jian [1 ]
Webb, John G. [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Dept Cardiol & Cardiothorac Surg, Vancouver, BC V6Z 1Y6, Canada
关键词
transcatheter aortic valve implantation; aortic stenosis; complications; ACUTE KIDNEY INJURY; VASCULAR COMPLICATIONS; EDWARDS SAPIEN(TM); CEREBRAL EMBOLISM; IMPLANTATION; BIOPROSTHESES; STENOSIS; RISK; EXPERIENCE; PERFORMANCE;
D O I
10.4244/EIJV7I1A10
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: There is heterogeneity in the reporting of procedural outcomes and complications following transcatheter aortic valve replacement (TAVR). Recently, new definitions have been proposed by the Valve Academic Research Consortium (VARC) in an effort to standardise these outcomes and improve the quality of future clinical research. The aim of this study is to report the procedural outcomes and complication rates following TAVR in a large sequential patient cohort using a balloon expandable valve according to the new VARC definitions. Methods and results: Three hundred and ten consecutive patients undergoing TAVR were assessed, including patients forming our early historical series at the infancy of TAVR. All complication rates were re-evaluated according to VARC definitions. Mean age was 82.2 +/- 8.1 years and the Society of Thoracic Surgeons score was 9.4 +/- 5.7%. Transfemoral 30-day mortality was 6.8% (3.8% in the second half of the cohort) and transapical 30-day mortality was 13.7% (9.4% in the second half of the cohort). Cardiovascular 30-day mortality was 7.4% and the composite safety endpoint at 30-days was 18.4%. Device success was 80% (post-procedural valve area <1.2 cm(2) in 9.7%). Failure to deliver and deploy a valve occurred in only 3.5%, with 82% (nine cases) occurring in the first half of the experience. Of those who did not meet echocardiographic criteria for device success (valve area <= 1.2 cm(2), transaortic gradient >= 20 mmHg or >= moderate aortic incompetence), 90% achieved a New York Heart Association class I/II. Life threatening bleeding complications occurred in 8.4%. In 7.7% of patients, red blood cell transfusions were given without evidence of overt bleeding. Major strokes occurred in 2.3% and acute kidney injury occurred in 6.5%. Conclusions: The VARC consensus guidelines provide a standardised reporting framework for clinical endpoints and complications post TAVR. We report the first series to our knowledge of 30-day outcomes using these definitions utilising a balloon expandable valve system.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 50 条
  • [41] The Vancouver Computed Tomography Sizing Guidelines for Transcatheter Aortic Valve Replacement with Balloon Expandable Valves
    Willson, Alex
    John, Webb
    Freeman, Melanie
    Wood, David
    Gurvitch, Ronen
    Thompson, Chris
    Moss, Robert
    Toggweiler, Stefan
    Binder, Ronald
    Munt, Brad
    Cheung, Anson
    Hague, Cameron
    Ye, Jian
    Leipsic, Jonathon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B31 - B31
  • [42] Echocardiographic Imaging of Procedural Complications During Balloon-Expandable Transcatheter Aortic Valve Replacement
    Hahn, Rebecca T.
    Kodali, Susheel
    Tuzcu, E. Murat
    Leon, Martin B.
    Kapadia, Samir
    Gopal, Deepika
    Lerakis, Stamatios
    Lindman, Brian R.
    Wang, Zuyue
    Webb, John
    Thourani, Vinod H.
    Douglas, Pamela S.
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (03) : 288 - 318
  • [43] BALLOON-EXPANDABLE VALVE GEOMETRY AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT IN PATIENTS WITH BICUSPID AORTIC STENOSIS
    Medranda, Giorgio
    Rogers, Toby
    Forrestal, Brian
    Case, Brian
    Yerasi, Charan
    Chezar-Azzerad, Chava
    Shults, Christian
    Torguson, Rebecca
    Shea, Corey
    Parikh, Puja
    Bilfinger, Thomas
    Cocke, Thomas
    Brizzio, Mariano
    Levitt, Robert
    Hahn, Chiwon
    Hanna, Nicholas
    Comas, George
    Zhang, Cheng
    Craig, Paige
    Asch, Federico
    Weissman, Gaby
    Garcia, Hector Garcia
    Ben-Dor, Itsik
    Satler, Lowell
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 925 - 925
  • [44] Outcomes of Direct Transcatheter Aortic Valve Replacement Without Balloon Aortic Valvuloplasty Using a New Generation Valve
    Aalaei-Andabili, Seyed Hossein
    Beaver, Thomas M.
    Bavry, Anthony A.
    Petersen, Johnw.
    Karimi, Ashkan
    Wayangankar, Siddharth
    Arnaoutakis, George
    Anderson, R. David
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (12) : 1100 - 1104
  • [45] Outcomes of Direct Transcatheter Aortic Valve Replacement without Balloon Aortic Valvuloplasty Using a New Generation Valve
    Aalaei-Andabili, Seyed Hossein
    Beaver, Thomas M.
    Bavry, Anthony A.
    Petersen, John W.
    Karimi, Ashkan
    Wayangankar, Siddharth
    Arnaoutakis, George
    Anderson, R. David
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (04) : S53 - S53
  • [46] Balloon-Expandable Transcatheter Aortic Valve Replacement in Patients with Severe Aortic Stenosis and Mild Aortic Valve Calcification
    Abramowitz, Yigal
    Jilaihawi, Hasan
    Chakravarty, Tarun
    Kashif, Mohammad
    Kazuno, Yoshio
    Maeno, Yoshio
    Takahashi, Nobuyuki
    Kawamori, Hiroyuki
    Sharma, Rahul P.
    Cox, Justin
    Cheng, Wen
    Makkar, Raj
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B257 - B257
  • [47] Transcatheter Valve-in-Valve Implantation for Failed Balloon Expandable Transcatheter Aortic Valves
    Toggweiler, Stefan
    Wood, David A.
    Rodes-Cabau, Josep
    Kapadia, Samir
    Ye, Jian
    Cheung, Anson
    Leipsic, Jonathon
    Gurvitch, Ronen
    Willson, Alexander B.
    Binder, Ronald K.
    Tuzeu, Murat E.
    Dumont, Eric
    Svensson, Lars G.
    Webb, John G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B36 - B37
  • [48] TRANSCATHETER VALVE-IN-VALVE IMPLANTATION FOR FAILED BALLOON EXPANDABLE TRANSCATHETER AORTIC VALVES
    Wood, D. A.
    Toggweller, S.
    Ye, J.
    Cheung, A.
    Leipsic, J.
    Gurvitch, R.
    Willson, A.
    Binder, R.
    Rodes-Cabau, J.
    Kapadia, S.
    Svensson, L.
    Webb, J. G.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S113 - S113
  • [49] Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
    Mack, M. J.
    Leon, M. B.
    Thourani, V. H.
    Makkar, R.
    Kodali, S. K.
    Russo, M.
    Kapadia, S. R.
    Malaisrie, S. C.
    Cohen, D. J.
    Pibarot, P.
    Leipsic, J.
    Hahn, R. T.
    Blanke, P.
    Williams, M. R.
    McCabe, J. M.
    Brown, D. L.
    Babaliaros, V.
    Goldman, S.
    Szeto, W. Y.
    Genereux, P.
    Pershad, A.
    Pocock, S. J.
    Alu, M. C.
    Webb, J. G.
    Smith, C. R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (18): : 1695 - 1705
  • [50] BALLOON-EXPANDABLE VERSUS SELF-EXPANDABLE TRANSCATHETER AORTIC VALVE REPLACEMENT
    Okumura, L.
    Sanchez, L.
    Alves, M.
    Candolfi, P.
    VALUE IN HEALTH, 2021, 24 : S68 - S68