Mathematical modeling based evaluation and simulation of boron removal in bioelectrochemical systems

被引:16
作者
Ping, Qingyun [1 ]
Abu-Reesh, Ibrahim M. [2 ]
He, Zhen [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Dept Civil & Environm Engn, Blacksburg, VA 24061 USA
[2] Qatar Univ, Coll Engn, Dept Chem Engn, POB 2713, Doha, Qatar
关键词
Boron removal; Bioelectrochemical systems; Microbial fuel cells; Microbial desalination cells; Mathematical modeling; Water treatment; WASTE-WATER TREATMENT; MICROBIAL FUEL-CELLS; ION-EXCHANGE MEMBRANES; DESALINATION CELLS; TRANSPORT; SEAWATER; TECHNOLOGY; BEHAVIOR;
D O I
10.1016/j.scitotenv.2016.06.220
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Boron removal is an arising issue in desalination plants due to boron's toxicity. As an emerging treatment concept, bioelectrochemical systems (BES) can achieve potentially cost-effective boron removal by taking advantage of cathodic-produced alkali. Prior studies have demonstrated successful removal of boron in microbial desalination cells (MDCs) and microbial fuel cells (MFCs), both of which are representative BES. Herein, mathematical models were developed to further evaluate boron removal by different BES and understand the key operating factors. The models delivered very good prediction of the boron concentration in the MDC integrated with Dorman Dialysis (DD) system with the lowest relative root-mean-square error (RMSE) of 0.00%; the predication of the MFC performance generated the highest RMSE of 18.55%. The model results of salt concentration, solution pH, and current generation were well filled with experimental data fur RMSE values mostly below 10%. The lung term simulation of the MDC-DD system suggests that the accumulation of salt in the catholyteistripping solution could have a positive impact on the removal of boron clue to osmosis-driven convection. The current generation in the MDC may have little influence on the boron removal, while in the MEC the current-driven electromigration can contribute up to 40% of boron removal. Osmosis-induced convection transport of boron could be the major driving force for boron removal to a low level <2 mg L-1. The ratio between the anolyte and the catholyte flow rates should be kept >22.2 in order to avoid boron accumulation in the anolyte effluent. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1380 / 1389
页数:10
相关论文
共 26 条
[1]  
Bennett A., 2013, FILTR SEP, V50
[2]   A New Method for Water Desalination Using Microbial Desalination Cells [J].
Cao, Xiaoxin ;
Huang, Xia ;
Liang, Peng ;
Xiao, Kang ;
Zhou, Yingjun ;
Zhang, Xiaoyuan ;
Logan, Bruce E. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (18) :7148-7152
[3]   Boron transport and removal using ion-exchange membranes: A critical review [J].
Dydo, P. ;
Turek, M. .
DESALINATION, 2013, 310 :2-8
[5]  
Grady C. P. L., 2011, BIOL WASTEWATER TREA
[6]   Desalination and sustainability - An appraisal and current perspective [J].
Gude, Veera Gnaneswar .
WATER RESEARCH, 2016, 89 :87-106
[7]   Boron removal from seawater: State-of-the-art review [J].
Guler, Enver ;
Kaya, Cuneyt ;
Kabay, Nalan ;
Arda, Muserref .
DESALINATION, 2015, 356 :85-93
[8]   Effect of temperature on seawater desalination-water quality analyses for desalinated seawater for its use as drinking and irrigation water [J].
Guler, Enver ;
Ozakdag, Deniz ;
Arda, Muserref ;
Yuksel, Mithat ;
Kabay, Nalan .
ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2010, 32 (04) :335-339
[9]   Influence of the chosen process parameters on the efficiency of seawater desalination: SWRO pilot plant results at Urla Bay seashore [J].
Guler, Enver ;
Piekacz, Jakub ;
Ozakdag, Deniz ;
Kujawski, Wojciech ;
Arda, Muserref ;
Yuksel, Mithat ;
Kabay, Nalan .
DESALINATION AND WATER TREATMENT, 2009, 5 (1-3) :167-171
[10]   Modeling the ion transfer and polarization of ion exchange membranes in bioelectrochemical systems [J].
Harnisch, Falk ;
Warmbier, Robert ;
Schneider, Ralf ;
Schroeder, Uwe .
BIOELECTROCHEMISTRY, 2009, 75 (02) :136-141