Experimental study on behavior of restrained high strength Q690 steel beams exposed to fire

被引:8
作者
Al-azzani, Hisham [1 ]
Wang, Weiyong [1 ,2 ]
Zhang, Yanhong [1 ]
Ding, Yong [1 ]
Xu, Jinyong [3 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Key Lab New Technol Construct Cities Mt Area, Minist Educ, Chongqing 400045, Peoples R China
[3] Shanghai Beststeel Steel Struct Bldg Syst Co Ltd, Shanghai 200949, Peoples R China
关键词
Axial restraint; Fire resistance; Restrained steel beam; Q690; steel; H-COLUMNS; TEMPERATURE; PERFORMANCE;
D O I
10.1016/j.jcsr.2022.107463
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In comparison to the isolated steel beam, the restrained steel beam is able to sustain fire loads using the effect of the surrounding restraints. However, Q690 steel has lower resistance to high temperatures than other types of carbon steel. To address this gap, a series of experimental tests on restrained high-strength Q690 steel beams subjected to fire are reported in this paper. Four full-scale restrained high-strength Q690 steel beams were investigated under several fire scenarios, and one was tested at room temperature. In this study, three transient tests and one steady-state test were chosen to fully comprehend the behavior of the restrained high-strength Q690 steel beams exposed to fire. Under the two test conditions, the impact of the steady-state and transient conditions on the fire response of the restrained Q690 steel beams are compared, and the variation of axial peak force, bearing capacity, and deflection were analyzed. The results showed that the critical temperature of the steady-state test is close to the critical temperature of the transient test, and the maximum axial force of the steady-state test is comparable to the one of the transient test. Due to the combined action of load and axial forces, the restrained Q690 steel beam generally develops flexural-torsional buckling failure after reaching the critical temperature in transient tests. In comparison, the steady-state test exhibits early flexural-torsional buckling behavior before reaching the critical temperature.
引用
收藏
页数:14
相关论文
共 31 条
[1]   Behaviour of restrained steel beam at elevated temperature - parametric studies [J].
Allam, Ahmed ;
Nassif, Ayman ;
Nadjai, Ali .
JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2019, 10 (03) :324-339
[2]  
[Anonymous], 2017, 512492017 GB CHIN EN
[3]  
[Anonymous], 2010, Metallic materials Tensile testing Part 1: Method of Test at Room Temperature
[4]  
[Anonymous], 2007, 199312 BSI EN
[5]  
[Anonymous], 1987, 47620 BS
[6]  
ASCE, 1992, Structural fire protection, ASCE committee on fire protection
[7]   Development and use of high performance steel [J].
Bjorhovde, R .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (3-5) :393-400
[8]   Application of fire-resistant steel to beam-to-column moment connections at elevated temperatures [J].
Chung, Hsin-Yang ;
Lee, Chen-Hung ;
Su, Wun-Jie ;
Lin, Rih-Zeng .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (02) :289-303
[9]  
Ding Y., 2022, Experimental Study on Fire Resistance of High Strength Q460 Steel Beam
[10]   A performance based methodology for fire design of restrained steel beams [J].
Dwaikat, M. M. S. ;
Kodur, V. K. R. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (03) :510-524