Point-of-care diagnostics for therapeutic monitoring of levofloxacin in human plasma utilizing electrochemical sensor mussel-inspired molecularly imprinted copolymer

被引:39
作者
El Azab, Noha F. [1 ]
Mahmoud, Amr M. [2 ]
Trabik, Yossra A. [1 ]
机构
[1] Ain Shams Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, Cairo 11566, Egypt
[2] Cairo Univ, Fac Pharm, Analyt Chem Dept, El Kasr El Aini St, Cairo 11562, Egypt
关键词
Therapeutic drug monitoring; Point-of-care diagnostics; Levofloxacin; Gold nanoparticles; Molecularly imprinted polymer; Poly(levodopa); REDUCED GRAPHENE OXIDE; GLASSY-CARBON ELECTRODE; CAPILLARY-ELECTROPHORESIS; SENSITIVE DETERMINATION; GOLD NANOPARTICLES; INJECTION-ANALYSIS; COMPOSITE FILM; HUMAN URINE; NANOTUBES; PARACETAMOL;
D O I
10.1016/j.jelechem.2022.116504
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Therapeutic drug monitoring is mandatory for drugs with narrow therapeutic index and is an integral part of the patient care standards, where drug concentration is measured in biological fluids to "personalize " patient's dosage. In this work a disposable electrochemical sensor has been developed for Levofloxacin (LEV) determination in human plasma. The selected substrate was pencil graphite electrode (PGE). To enhance the sensor performance, the PGE has been modified with Au-NPs via electrochemical deposition. To achieve high selectivity towards levofloxacin, the PGE/Au-NPs electrode has been further modified with molecularly imprinted copolymer; poly(L-dopa)/poly(o-phenylenediamine), by anodic electropolymerization of the corresponding monomers. The Levodopa not only acts as a functional monomer but moreover, a substrate for mussel-inspired polymer. The sensor surface has been characterized using both scanning electron microscopy (SEM) imaging and X-ray photoelectron spectroscopy (XPS) to investigate the morphology and elemental composition of the modified PGE, respectively. To optimize the sensor performance, experimental variables were studied and tuned to improve the outcomes. The sensor has a linear response in two concentration windows (1.0 x 10(-6)-1.0 x 10(-4 )mol/L) and (1.0 x 10(-4)-1.0 x 10(-2) mol/L) Levofloxacin, with a limit of detection of 4.62 x 10(-7 )mol/L. Selectivity, repeatability, and low manufacturing cost are some benefits of the proposed sensor. The sensor was successfully used to determine Levofloxacin in Tavanic (R) tablets and spiked plasma samples.
引用
收藏
页数:8
相关论文
共 76 条
[1]   Novel potentiometric sensors for the determination of the dinotefuran insecticide residue levels in cucumber and soil samples [J].
Abdel-Ghany, Maha F. ;
Hussein, Lobna A. ;
El Azab, Noha F. .
TALANTA, 2017, 164 :518-528
[2]   Impedimetric Sensors for Cyclocreatine Phosphate Determination in Plasma Based on Electropolymerized Poly(o-phenylenediamine) Molecularly Imprinted Polymers [J].
Abo-Elmagd, Ibrahim F. ;
Mahmoud, Amr M. ;
Al-Ghobashy, Medhat A. ;
Nebsen, Marianne ;
El Sayed, Nesrine S. ;
Nofal, Shahira ;
Soror, Sameh H. ;
Todd, Robert ;
Elgebaly, Salwa A. .
ACS OMEGA, 2021, 6 (46) :31282-31291
[3]   Liquid-liquid Extraction Coupled to Batch Injection Analysis for Electroanalysis of Levofloxacin at Low Concentration Level [J].
Alencar, Leticia Machado ;
de Oliveira, Luiz Henrique ;
Backes, Rafael ;
Rosa, Tamires Macedo ;
de Oliveira, Paulo Roberto ;
Bezerra da Silva, Rodrigo Amorim ;
Goncalves Trindade, Magno Aparecido .
ELECTROANALYSIS, 2017, 29 (11) :2559-2564
[4]   The determination of levofloxacin by flow injection analysis using UV detection, potentiometry, and conductometry in pharmaceutical preparations [J].
Altiokka, G ;
Atkosar, Z ;
Can, NO .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) :881-885
[5]   Coating zwitterionic amino acid L-DOPA to increase fouling resistance of forward osmosis membrane [J].
Anh Nguyen ;
Azari, Sara ;
Zou, Linda .
DESALINATION, 2013, 312 :82-87
[6]   On-Site Therapeutic Drug Monitoring [J].
Ates, H. Ceren ;
Roberts, Jason A. ;
Lipman, Jeffrey ;
Cass, Anthony E. G. ;
Urban, Gerald A. ;
Dincer, Can .
TRENDS IN BIOTECHNOLOGY, 2020, 38 (11) :1262-1277
[7]   Potentiometric Carbon Quantum Dots-Based Screen-Printed Arrays for Nano-Tracing Gemifloxacin as a Model Fluoroquinolone Implicated in Antimicrobial Resistance [J].
Ayad, Miriam F. ;
Trabik, Yossra A. ;
Abdelrahman, Mona H. ;
Fares, Nermine V. ;
Magdy, Nancy .
CHEMOSENSORS, 2021, 9 (01) :1-16
[8]   Molecularly imprinted polymer-based sensor for electrochemical detection of erythromycin [J].
Ayankojo, Akinrinade George ;
Reut, Jekaterina ;
Ciocan, Valeriu ;
Opik, Andres ;
Syritski, Vitali .
TALANTA, 2020, 209
[9]   Using zwitterionic amino acid L-DOPA to modify the surface of thin film composite polyamide reverse osmosis membranes to increase their fouling resistance [J].
Azari, Sara ;
Zou, Linda .
JOURNAL OF MEMBRANE SCIENCE, 2012, 401 :68-75
[10]   How to Improve the Performance of Electrochemical Sensors via Minimization of Electrode Passivation [J].
Barek, Jiri .