Comparison of Clinical Outcomes, Radiological Outcomes and Bone Remodeling Outcomes Between Proximal Coated Single-Wedge New Stem and Full Coated Dual-Wedge Classic Stem in 1-Stage Bilateral Total Hip Arthroplasty

被引:3
|
作者
Hu, Hongpeng [1 ]
Liu, Zeming [1 ]
Liu, Bo [1 ]
Ding, Xuzhuang [1 ]
Liu, Sikai [1 ]
Wu, Tao [1 ]
Ma, Wenhui [1 ]
Han, Yongtai [1 ]
机构
[1] Hebei Med Univ, Dept Osteonecrosis & Hip Surg, Hosp 3, Shijiazhuang, Hebei, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2020年 / 26卷
关键词
Arthroplasty; Replacement; Hip; Bone Density; Femur Head Necrosis; Hip Prosthesis; TITANIUM FEMORAL COMPONENT; LEG LENGTH DISCREPANCY; QUALITY-OF-LIFE; FOLLOW-UP; MUSCLE STRENGTH; STRAIGHT STEM; OFFSET; IMPLANTATION; REPLACEMENT; RECOVERY;
D O I
10.12659/MSM.921847
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: This retrospective study investigated the clinical outcomes, radiological outcomes, and bone remodeling pat- terns associated with a Medial/Lateral Taper (M/L Taper) stem and Link Classic Uncemented (LCU) stem in 1-stage bilateral total hip arthroplasty (THA). Material/Methods: The results of 52 patients who underwent 1-stage bilateral THA with a M/L Taper stem on one side and an LCU stem on the other between January 2012 and February 2015 were retrospectively compared. Patients were clinically assessed by the Harris hip score (HHS), visual analogue score (VAS) and incidence of complications. Radiological indicators were measured. Periprosthetic bone remodeling was assessed via bone mineral density (BMD) measurements. Results: The mean follow-up time was 5.2 years. At each follow-up, there was no difference in the HHS and VAS be- tween the 2 groups. The neck-shaft angle, offset, vertical height of the rotational center and limb lengthening were lower in the M/L Taper group than in the LCU group (P<0.001). The Engh total score was lower in the LCU group (P=0.039). Significantly higher (P<0.001) BMDs were observed in the M/L Taper group in Gruen zones 1, 2, and 6. significantly lower (P<0.001) BMDs were observed in the M/L Taper group in Gruen zones 3 and 5. Conclusions: Due to the increased postoperative neck-shaft angle, the full coated dual-wedge classic stem was prone to cause lower limb lengthening. The proximal coated single-wedge new stem patients were more likely to have an insufficient postoperative neck length. The new stem achieved load transfer and proximal fixation, leading to better proximal femoral bone preservation is more in line with human biomechanical characteristics.
引用
收藏
页数:11
相关论文
共 2 条
  • [1] Comparison of Bone Remodeling Between an Anatomic Short Stem and a Straight Stem in 1-Stage Bilateral Total Hip Arthroplasty
    Koyano, Gaku
    Jinno, Tetsuya
    Koga, Daisuke
    Yamauchi, Yuki
    Muneta, Takeshi
    Okawa, Atsushi
    JOURNAL OF ARTHROPLASTY, 2017, 32 (02) : 594 - 600
  • [2] Influence of femoral morphology and canal fill ratio on early radiological and clinical outcomes of uncemented total hip arthroplasty using a fully coated stem
    D'Ambrosio, A.
    Peduzzi, L.
    Roche, O.
    Bothorel, H.
    Saffarini, M.
    Bonnomet, F.
    BONE & JOINT RESEARCH, 2020, 9 (04): : 182 - 191